SOM06075

S/CON/SOM06075/C/18/12/14
Page 1/6 UK
MOSFET BASED
DC SOLID-STATE RELAY
SOM06075
(With built-in transient voltage suppressor)
 Latest MOSFET technology generation.
 Ultra low on-state resistance.
 Low output leakage current.
 Low control current consumption.
 Built-in overvoltage protection (TVS)
 Reverse protected triggered control input to avoid linear control risks
 No radiated or conducted disturbances
 Touch protected housing IP20
DC Mains
voltage range
5-40VDC
(75Vpeak)
Fig. 1
Load current range
Up to 60A
(with heatsink)
Control voltage range
3.5-32VDC
Max transient peak
voltage
Max. DC Mains peak
voltage
Max. Load Current
(with heatsink)
75V
40VDC
60ADC
Control input
voltage range
In & case / Out
Insulation
Connections
Dimensions
(WxHxD)
Weight
3.5-32VDC
2.5kV
Screw terminals
45 x 58.5 x 30
80g
HIGH SIDE WIRING DIAGRAM
(Load connected to “-“)
LOW SIDE WIRING DIAGRAM
(Load connected to “+”)
Fig. 2
Please consult us
to select the right
protective
components C1 &
D2.
(see also accessory
list page 5)
Please consult us
to select the right
protective
components C1 &
D2.
(see also accessory
list page 5)
The red paths
(C1/D2) must be
as short as
possible !
Fig. 3
Proud to serve you
Data given at Tambient=25°C and subject to modification without previous notice
The red paths
(C1/D2) must be as
short as possible !
INTERNAL DIAGRAM
celduc
®
r
e
l
a
i
s
celduc®
r
e
l
a
i
S/CON/SOM06075/C/18/12/14
s
Page 2/6 UK
CONTROL INPUT CHARACTERISTICS
INPUT CIRCUIT
CHARACTERISTIC
LABEL
VALUE
INFO.
Nom. Control voltage
Ucnom
12-24VDC
Nom. Control current
Control voltage range
Control current
consumption
Icnom
Uc
35mADC
3.5 – 32VDC
typical=3.3V
Ic
32 – 35mADC
See curve
Ucoffmax
1VDC
Typical= 2.6V
CONTROL CURRENT
vs. CONTROL VOLTAGE
Fig. 4
Ic (mADC)
50
-100µA/°C
-35°C
-35°C
45
40
25°C
35
30
100°C
25
Releasing control voltage
20
15
Max. reverse control
voltage
10
-Ucmax
32VDC
-Icmax <100µA
Rin
Current
limitation
See curve
5
0
Input impedance
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
Uc (VDC)
TIME CHARACT.
TIME CHARACTERISTICS
CHARACTERISTIC
LABEL
VALUE
Turn on time
ton
20µs
Turn on delay
tdon
20µs
Turn off time
toff
20µs
Turn off delay
tdoff
20µs
F(on-off)
>1000Hz
Max. On-Off frequency
For high frequency, take 2 x Ie to calculate the heatsink; the protections must
be chosen carefully. Please consult us if any.
POWER OUTPUT CHARACTERISTICS
CHARACTERISTIC
Nominal voltage
POWER CIRCUIT
Voltage range
LABEL
VALUE
Uenom
24VDC
Ut
Ue
INFO.
5-40VDC
Utmax=40VDC
Non-repetitive peak voltage
Utp
75V
Overvoltage protection
D1
39V (Transient voltage suppressor)
1500W / 1ms
See fig.10 & 11
Off-state max reverse voltage drop
(internal diode)
-Ut
0.92V
@Ie=75A & @Uc=0
See fig. 6
Resistive
Motor
60A
Please contact us
Maximum nominal currents
Ie max
Max. non-repetitive peak current
Iepeak
Min. load current
Iemin
5mA
Ielk max
3mA
Max. leakage current
Switch OFF D<1%
Switch OFF Fmax
ON-state
294A
60A
750A
8.2mOhms @Tj=125°C
@Tc=100°C @Tj=175°C
@Utp (See
fig. 8)
@Utmax @Tjmax
Max. on-state resistance
RDSon
Typ. output capacitance
Cout
1.5nF
Rthjc
1.2K/W
Rthra
10K/W
@Tra=75°C
Heatsink thermal time constant
Tthra
10 minutes
@Tra=60°C
Control inputs/power outputs
insulation voltage
Uimp
2.5kV
Inputs/case insulation voltage
Uimp
2.5kV
Outputs/case insulation voltage
Uimp
2.5kV
Junction/case thermal resistance per
power element
Built-in heatsink thermal resistance
vertically mounted
4.5mOhms @Tj=25°C
See fig. 9
Isolation resistance
Rio
1G
Isolation capacitance
Cio
<8pF
Maximum junction temperature
Storage ambient temperature
Operating ambient temperature
Max. case temperature
Tjmax
175°C
Tstg
-40->+100°C
Tamb
-25->+90°C
Tc
100°C
@Iemax
@Utp
See fig. 9
celduc®
r
e
l
a
i
S/CON/SOM06075/C/18/12/14
s
Page 3/6 UK
OUTPUT SWITCH CHARACTERISTIC CURVES
Fig. 5
ON RESISTANCE VS JUNCTION TEMPERATURE
REVERSE VOLTAGE DROP
VS REVERSE CURRENT
Fig. 6
1000
RDSon
12
(mOhms)
10
-Ie (A)
100
8
Uc=0 ; Tj=125°C
10
6
Uc≠0 ; Tj=125°C
4
1
2
-Ut (V)
0
-50
0
50
100
0,1
150
0
Tj (°C)
Fig. 7
POWER ELEMENT TRANSIENT THERMAL IMPEDANCE
vs. PULSE DURATION
Zthjc (K/W)
0,35
700
0,3
0,2
D=5%
Repetitive D=5% (Tc=100°C, Tjm ax=175°C)
Repetitive D=10% (Tc=100°C, Tjm ax=175°C)
100
D=1%
Repetitive D=50%(Tc=100°C, Tjm ax=125°C)
Single pulse
0
0,0001
0,001
0,01
Fig. 9
0,1
Repetitive D=20% (Tc=100°C, Tjm ax=175°C)
200
D=2%
0,05
3
300
D=10%
0,1
2,5
400
D=20%
0,15
2
Non-repetitive D=1% (Tc=100°C, Tjm ax=175°C)
500
D=50%
1,5
Ie (Apk)
600
0,25
1
ON-STATE PEAK OVERLOAD CURRENT vs. PULSE
DURATION
Fig. 8
800
0,5
t (s)
0
0,0001
0,001
0,1 Pulse 1
Duration (s)
0,01
1
POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE
Permanent current
Ie (ARMS)
Power dissipated
Pd (W)
Please refer to the installation notice for precautions about
mounting the device on a heatsink.
65
34.8
0.75K/W
60
29.7
55
24.9
20.6
50
0.55K/W
16.7
45
0.3K/W
40
13.2
35
10.1
30
7.42
25
5.15
20
3.3
15
1.85
10
0.82
5
10K/W
4K/W
2.2K/W
0.21
2.1K/W
1.2K/W
1.1K/W
0.9K/W
0
0
0
10
10K/W = No Heatsink / 1LD12020
2.1K/W = WF210000
0.9K/W = WF115100
20
30
40
50
60
4K/W = 150x150x3mm aluminium sheet
1.2K/W = WF121000
0.75K/W = WF070000
70
80
90
100
110
Ambient temperature (°C)
2.2K/W = WF262100 / WF151200
1.1K/W = WF131100
0.55K/W = WF050000
0.3K/W = WF031100
celduc®
r
e
l
a
i
S/CON/SOM06075/C/18/12/14
s
Page 4/6 UK
BUILT-IN OVERVOLTAGE PROTECTION CHARACTERISTICS
Fig.
10
LEAKAGE CURRENT (Ielk)
VS DC OUTPUT SWITCH VOLTAGE (Ut)
Fig.
11
OVERVOLTAGE DURATION
AND FREQUENCY ABSOLUTE LIMITS
Uto  Utp
Ielk / Ie
1
0,8
t max 
0,6
0,4
P ( protection )  1W max
( Uto  Ut max)  Ie  t

1
T
0,2
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Ut (V)
U t max
( =U emax)
0. 75
( Uto  Ut max)  Ie
Utp
Ielk : Leakage current of the relay
Ie : User load nominal current
Utp : Relay max. non repetitive peak voltage
Utmax : Max. nominal voltage of the relay
t : Overvoltage duration
Uto : Possible overvoltage above Utmax
T: Time between 2 overvoltage
Utn = Ue : User DC power supply voltage
GENERAL INFORMATION
Green LED
(indicates relay has switched ON)
MISC.
Display
Housing
UL94V0
Mounting
2 screws (M4x12mm ; tightening = 1.2N.m)
Noise level
None
Weight
See mounting
sheet
80g
E.M.C.
IMMUNITY
GENERAL
STANDARDS
Standards
IEC60947-1
Protection level
IP20
Protection against direct touch
Yes
CE marking
Yes
UL, cULUS
Yes
TYPE OF TEST
STANDARD
LEVEL
Fast transients bursts
EN61000-4-4
4kV criterion B
Electric chocks
EN61000-4-5
1kV criterion B
Voltage drop
EN61000-4-11
-
EFFECT
celduc®®
celduc
r
r
e
e
l
l
a
a
i
i
S/CON/SOM06075/B/22/08/13
S/CON/SOM06075/C/18/12/14
s
s
Page 5/6 UK
CO N N ECT IO N S
IP20 flaps
Flaps are delivered mounted on the relay.
Labels
Marking labels are available,
for mounting on flaps.
Part number : 1MZ09000
(delivered per 200 parts)
FASTONS : Consult us
celduc®
r
e
l
a
i
S/CON/SOM06075/C/18/12/14
s
Page 6/6 UK
DIMENSIONS AND ACCESSORIES
Fig.
12
DIMENSIONS (mm)
CAD documents : www.celduc-relais.com/uk/plan3D.asp
1+
2-
ACCESSORIES
READY TO USE OVERVOLTAGE PROTECTION
ESO01000
(Please check our website for availability)
This device includes a diode (D2) and a capacitor (C1) suitable for most of the DC
application.
To be mounted close to the SOM.
Please consult our website for other accessory references
(Heatsinks, mounting adaptors, thermal grease…)
celduc®
r
e
l
a
i
s
www.celduc.com
5 Rue Ampère B.P. 30004
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19