http://www.alliedcomponents.com/pdf/AEE16-1155-RC.pdf

RoHS
AEE16-1155
High Frequency Transformer
ELECTRICAL SPECIFICATIONS:
1. INDUCTANCE: 100KHz/0.1V (HP-4284A)
2 - 1: 235µH ± 10%
2. LEAKAGE INDUCTANCE: 100KHz/0.1V (HP-4284A)
2 - 1: 50µH MAX (SHORT 6-5)
3. DCR: (CH-502A AT 25ºC)
2 - 1: 0.33 OHM MAX
6 - 5: 24 mOHM MAX
4. HI-POT TEST:
PRI TO SEC : AC 3000V 3mA FOR 1 SEC
CORE TO COIL : AC 1000V 3mA FOR 1 SEC
5. INSULATION TEST:
PRI TO SEC & COIL TO CORE : 100 mOHM MIN BY DC 500V
6. GAP : CORE CENTER GAP
714-665-1140
ALLIED COMPONENTS INTERNATIONAL
REVISED 10/07/10
www.alliedcomponents.com