RoHS AEE16-1155 High Frequency Transformer ELECTRICAL SPECIFICATIONS: 1. INDUCTANCE: 100KHz/0.1V (HP-4284A) 2 - 1: 235µH ± 10% 2. LEAKAGE INDUCTANCE: 100KHz/0.1V (HP-4284A) 2 - 1: 50µH MAX (SHORT 6-5) 3. DCR: (CH-502A AT 25ºC) 2 - 1: 0.33 OHM MAX 6 - 5: 24 mOHM MAX 4. HI-POT TEST: PRI TO SEC : AC 3000V 3mA FOR 1 SEC CORE TO COIL : AC 1000V 3mA FOR 1 SEC 5. INSULATION TEST: PRI TO SEC & COIL TO CORE : 100 mOHM MIN BY DC 500V 6. GAP : CORE CENTER GAP 714-665-1140 ALLIED COMPONENTS INTERNATIONAL REVISED 10/07/10 www.alliedcomponents.com