High Current/High Voltage Resin Sealed Filters High current filters are ideal for use in high current 5 volt logic buss, but also can be used for ±48 VDC telephone rack buss, high current switch mode power supplies and DC charging systems. High voltage filters find use in high voltage power supplies and applications requiring U.L. Hi-Pot. Installation Notes for Figure 1 & 2 — see below (Figure 3 see page CF6) Features ■ Current ratings up to 100 Amps ■ Continuous voltage ratings up to 1250 VDC/240 VAC (400Hz) 1. Mounting installation torque Method A: Mounting in full threaded through-hole Maximum torque: 96 in-lbs ■ U.L. 1459 recognized and CSA C22.2 approved versions available ■ Rugged bolt-in style for easy installation Method B: Mounting w/hardware Maximum torque: 84 in-lbs 2. Terminal installation torque Maximum torque: 20 in-lbs Note: Use two-wrench method to install terminal hardware 1-1/2 Imperfect Thds. 5/16–24 Unf–2A Thd. .250 (6.35) .060 Max., Typ. ø .062 ± .005 (1.58 ± .13) Typ. .250 (6.35) Min. .250 (6.35) .250 (6.35) Min. Typ. . .250 (6.35) Figure 3 .815 ( Hex. .500 (12.7) Hex. .563 ( Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 LP24 High Current/High Voltage Resin Sealed Filters High Current High Voltage Feed-through 1.000 ± .031 (25.4 ± .79) 1.250 ± .031 (31.8 ± .79) .312 (7.93) .375 (9.53) .250 Flats ø .051 ± .005 (ø 1.30 ± .13) .327 Max. (8.30 Max.) .578 Max. (14.68 Max.) Mounting Surface 5/16–24 Unf–2A Figure 4 .990 ± .031 (25.15 ± .79) .500 (12.7) .325 (8.26) ø .057 ± .005 (ø 1.45 ± .13) .075 (1.91) .740 ± .031 (18.61 ± .79) Mounting Surface 3/8–32unef–2A Thd. .375 (9.53) .500 (12.70) .689 ± .031 (17.5 ± .79) .937 ± .031 (23.8 ± 79) .020 (.51) Figure 5 .125 (3.18) 3/8–32 Unef–2A Thd. Figure 6 Dimensions in inches (mm) Rated Voltage 125°C DC AC*** 60 — I Amp 50 CKT C Min Cap 0.22 µF Minimum Insertion Loss (dB) 10 1 3 1 10 30 100 300 MHz MHz MHz MHz MHz MHz GHz GHz 50 50 40 50 50 50 30 20 54-848-005* Figure 1 54-853-001* 2 60 — 50 C 0.22 µF 20 30 40 50 50 50 50 50 54-853-004 € 2 200 140 100 C 0.22 µF 20 30 40 50 50 50 50 50 54-848-008 1 200 140 100 C 0.22 µF 20 30 40 50 50 50 50 50 54-844-001** 3 600 240 25 C 4700 pF ± 20% — — 12 20 30 33 50 50 54-844-002** 3 600 240 25 C 0.01 µF ± 20% 3 7 20 25 35 40 57 57 54-763-008 4 750 — 25 C 1000 pF — — — 10 20 28 28 28 54-763-009 4 750 — 25 C 4000 pF — — 10 22 32 35 35 40 54-789-003 5 1250 — 25 C 4000 pF — — 6 20 30 35 35 35 ✝ 1280-060 € 6 2500 — 25 Pi 1500 pF — — 5 15 50 50 50 50 Part Number ✝ Also available through API’s authorized distributors. € Also available through API’s authorized European distributors/agents. * Denotes parts that are UL recognized to UL 60950 and certified to CSA C22.2 ** Denotes parts that meet 1500 VAC Dielectric Withstanding Voltage per UL 1283 *** AC Voltage to be 400Hz and CSA C22.2 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 LP25