Click Here to download this file: /data/apnotes/acan-59.pdf

D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
PMBus™ Commands & Features
This application note is applicable for the following members of the D1U54P-W-650-12-HBxC-xxx Series:
MPS#
Model Number
M1845
N/A
M1876
D1U54P-W-650-12-HB4C
M1871
D1U54P-W-650-12-HB4C-AB
M1877
D1U54P-W-650-12-HB3C
M1872
D1U54P-W-650-12-HB3C-AB
Serial Communication Slave Addressing
Airflow
Standby (Vdc)
Back-to-Front
ADDR_Select (External Resistor)
12
front-to-back
Standard PMBus™ Commands
All data communicated over the PMBus™ interface uses PEC (Packet Error Checking) as defined by the standard for PMBus™ Power Systems Management Protocol Part 1 – General
Requirements Rev 1.1.
Linear data formatting is used for all passed parameters. It is strongly recommended to fully utilize the PEC byte to validate all transactions and to repeat if not validated. Block reads
(where the loose byte received denotes the remaining byte to be clocked out) are not supported on this product series.
A minimum of 300µs delay between transactions (between the STOP of one command and the START of the next command) is recommended for robust communications.
Note: 100/400 KHz I2C communications is supported for the PMBus™ interface.
Note: The PMBus™ slave controller does “clock stretch” on ACK or NAK.
Device Details
Power Module Internal Devices
Vendor
Microchip Technology Inc.
Microchip Technology Inc.
Microchip Technology Inc.
Manufacturers
Part Number
DSPIC33FJ16GS504T-50I/PT
DSPIC33FJ64GS606T-50I/PT
24AA024T- I /MS
Package
Description
44 Pin
64 Pin
8 Pin
Primary Digital Signal Controller, 16-bit dsPIC, 32K flash, 2K SRAM, --40C to +85C
Secondary Digital Signal Controller, 16-bit dsPIC, 64K flash, 9K SRAM, -40C to +85C
2K Bit, 2.5-5.5V, 400KHz, 1.8-2.5V 100KHz, -40C to +85C
Device Addressing Methods
(See D1U54P-12-CONC Interface Card; Application Note ACAN-64 for Additional Details):
There are two methods whereby the three lower order address bits of the seven bit address structure of the internal addressable devices can be assigned (for the secondary
microcontroller and the EEPROM device A0, A1 & A2; see the PMBus™ standard). These are as follows:
1.
Using the ADDR signal pin (Pin# A3) in digital mode by either:
a.
Un-terminating (leaving open circuit); this will set a default setting of “111” for the last three addressable bits (A0, A1 & A2) of the seven bit address byte.
b.
Terminating the pin to RTN/ground (Pin numbers A2/B2); this method will set a default address of “000” for the last three addressable bits (A0, A1 & A2) of the address
byte.
2.
Using the ADDR signal pin (Pin# A3) in analogue mode by connection of an external resistance to RTN/ground (pin numbers A2/B2).
For the possible external resistance values this will result in the following address combinations:
HEX Address Combinations by Analogue Method; ADDR External Resistance Values
ADDR External Resistance to RTN/Ground
Power Module Secondary
Power Module
(KΩ; ±5% Tolerance)
Main Controller (Serial Slave Address)
EEPROM (Serial Slave Address)*
0.82
0xB0
0xA0
2.7
0xB2
0xA2
5.6
0xB4
0xA4
8.2
0xB6
0xA6
15
0xB8
0xA8
27
0xBA
0xAA
56
0xBC
0xAC
180
0xBE
0xAE
The D1U54P-W-650-12-HBxC-xxx uses 7-bit “left shifted” device addressing; the EEPROM addressing follows a similar convention (commences at base address 0xA0); the lowest order
bit of the address is the Read/Write bit. It is assumed that the Read Write bit is set to logic “0” (for addresses shown in the table above).
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 1 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
PMBus™ COMMANDS
Command Codes
Page Command is supported to allow the ability to control and monitor the dual outputs (the Main 1 output and VSTANDBY outputs). Each Command
Code is annotated with either “All”, “0”, “1”, “2” or “3” accordingly to identify which “page” is associated with the command.
Command Code
(Hex)
00
01
02
03
19
Read/
Write
R/W
Page
OPERATION
(See Relevant Table at the Rear of Document)
#ComCodex01
R/W
All
ON_OFF_CONFIG
See Relevant Table at the Rear of Document)
#ComCodex02
R
Command Name
PAGE
CLEAR_FAULTS
CAPABILITY
W
R
Format
All
All
Bit Flags
Bit Flags
All
All
Number of
Bytes
1
Bit(s)
Number
1
5:0
Set output margin high/low voltages
7:6
Turn the unit on/off in conjunction with digital
input from PSON_L
Set when Turn off immediately (default) / 0 =
Use delay @ turn-off
Set when Power on processing is active high
(default)
Set when Use CONTROL pin for on/off power
processing (default)
Set when Use OPERATION command for on/off
power processing (default)
Set when Use both CONTROL pin &
OPERATION command (default)
1
0
ON_OFF_DELAY
1
ON_OFF_POLARITY
2
USE_CONTROL
3
USE_OPERATION
4
USE_CNTL_AND _OP
5
6
7
RESERVED
RESERVED
RESERVED
1
Bit Flags
1
0:3
7
20
21
25
25
26
26
VSTBY_MODE
VOUT_COMMAND
VOUT_MARGIN_HIGH
VSTBY_MARGIN_LOW
VOUT_MARGIN_HIGH
VSTBY_MARGIN_LOW
R
R
R/W
R/W
R/W
R/W
R/W
0
1
All
0
1
0
1
Bit Flags
Bit Flags
Linear Data Format
Linear Data Format
Linear Data Format
Linear Data Format
Linear Data Format
1
1
2
2
2
2
2
RESERVED
SMBALERT_L
MAX_BUS_SPEED
PEC
Supported
YES
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
Write only command clears all faults that have
been set in all the STATUS_XXXX registers
simultaneously
6:5
VOUT_MODE
Definition
Command to provide ability to configure,
control & monitor multiple outputs
4
20
Bit Name
Set when device has SMBALERT_L pin which
supports the SMBus Alert Response protocol
01 = Max supported bus speed = 400kHz; 00
Max supported bus speed = 100kHz
Set when packet error checking is supported
Single data byte sets the READ_VOUT sensor
to linear mode data format and supplies
required N exponent. To translation to volts.
PMBus Spec - Part II - Revision 1.1 - Sections
8.1-8.3
Single data byte sets the READ_VOUT sensor
to linear mode data format and supplies
exponent “N” for translation to volts.
PMBus Spec - Part II - Revision 1.1 - Sections
8.1-8.3
Manual override main output set point
command - Voltage range setting 11.5V 12.75V
Command formatted in Linear as per
command 0x8B – READ_VOUT
Load the unit with the voltage to which the
output is to be changed when the OPERATION
command set to "Margin High"
YES
NO
YES
YES
YES
YES
YES
YES
NO
Load the unit with the voltage to which the
output is to be changed when the OPERATION
command set to "Margin High"
NO
Load the unit with the voltage to which the
output is to be changed when the OPERATION
command set to "Margin Low"
NO
Load the unit with the voltage to which the
output is to be changed when the OPERATION
command set to "Margin Low"
NO
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 2 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code
(Hex)
Command Name
Read/
Write
R
3A
Page
All
Format
Bit Flags
Number
of Bytes
1
FAN_CONFIG_1_2
3B
FAN_COMMAND_1
R/W
All
Linear Data Format
2
3C
FAN_COMMAND_2
R/W
All
Linear Data Format
2
40
VOUT_OV_FAULT_LIMIT
R
0
Linear Data Format
2
Bit(s)
Number
Bit Name
0
FAN_2_TACH_PULSES
1
FAN_2_TACH_PULSES
2
FAN_2_SETTING_MODE
3
FAN_2_INSTALLATION
4
FAN_1_TACH_PULSES
5
FAN_1_TACH_PULSES
6
FAN_1_SETTING_MODE
7
FAN_1_INSTALLATION
Definition
Fan 2 Tachometer pulses per revolution (lower
bit)
Fan 2 Tachometer pulses per revolution (upper
bit)
Set when fan is commanded in RPM (Clear
when fan is commanded in Duty Cycle)
Set when fan is installed in position 2
Fan 1 Tachometer pulses per revolution (lower
bit)
Fan 1 Tachometer pulses per revolution (upper
bit)
Set when fan is commanded in RPM (Clear
when fan is commanded in Duty Cycle)
Set when fan is installed in position 1
Manual fan override command fan speed
value by duty cycle
Command speed formatted in Linear as per
command 0x90 - READ_FAN_SPEED_1
Manual fan override command fan speed
value by duty cycle
Command speed formatted in Linear as per
command 0x90 - READ_FAN_SPEED_2
Main Output Overvoltage Fault Limit
Standby(Auxiliary) Output Overvoltage Fault
Limit
Main Output Overvoltage Fault Response
Actions
Standby(Auxiliary) Output Overvoltage Fault
Response Actions
Supported
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
YES
40
VSTBY_OV_FAULT_LIMIT
R
1
Linear Data Format
2
41
VOUT_OV_FAULT_RESPONSE
R
0
Bit Flags
1
41
VSTBY_OV_FAULT_RESPONSE
R
1
Bit Flags
1
42
VOUT_OV_WARN_LIMIT
R
0
Linear Data Format
2
Main Output Overvoltage Warning Limit
YES
42
VSTBY_OV_WARN_LIMIT
R
1
Linear Data Format
2
Standby(Auxiliary) Output Overvoltage Warning
Limit
YES
43
VOUT_UV_WARN_LIMIT
R
0
Linear Data Format
2
Main Output Undervoltage Warning Limit
YES
43
VSTBY_UV_WARN_LIMIT
R
1
Linear Data Format
2
Standby(Auxiliary) Output Undervoltage
Warning Limit
YES
44
VOUT_UV_FAULT_LIMIT
R
0
Linear Data Format
2
Main Output Undervoltage Fault Limit
YES
44
VSTBY_UV_FAULT_LIMIT
R
1
Bit Flags
1
45
VOUT_UV_FAULT_RESPONSE
R
0
Bit Flags
1
45
VSTBY_UV_FAULT_RESPONSE
R
1
Linear Data Format
2
46
IOUT_OC_FAULT_LIMIT
R
0
Linear Data Format
2
46
ISTBY_OC_FAULT_LIMIT
R
2
Bit Flags
1
47
IOUT_OC_FAULT_RESPONSE
R
0
Bit Flags
1
47
ISTBY_OC_FAULT_RESPONSE
R
2
Linear Data Format
2
4A
IOUT_OC_WARN_LIMIT
R
0
Linear Data Format
2
4A
IOUT_OC_WARN_LIMIT
R
1
Linear Data Format
2
4A
ISTBY_OC_WARN_LIMIT
R
2
Linear Data Format
2
See Returned Data Tables for
Individual Models
#HB4xCcomcodex40
#HB3xCcomcodex40
Standby(Auxiliary) Output Undervoltage Fault
Limit
Main Output Undervoltage Fault Response
Actions
Standby(Auxiliary) Output Undervoltage Fault
Response Actions
Main Output Overcurrent Fault Limit - High
line
Standby(Auxiliary) Output Overvoltage Fault
Limit
Main Output Overcurrent Fault Response
Actions
Standby(Auxiliary) Output Response Actions
Standby(Auxiliary) Output Overcurrent Fault
Response Actions
Main Output Overcurrent Warning Limit - High
line
Main Output Overcurrent Warning Limit - Low
line
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
4F
AIRFLOW_1_OT_FAULT_LIMIT
R
2
Linear Data Format
2
Airflow 1 Overtemperature Fault Limit
YES
4F
HOTSPOT_1_OT_FAULT_LIMIT
R
1
Linear Data Format
2
Hotspot 1 Overtemperature Fault Limit
YES
4F
AIRFLOW_2_OT_FAULT_LIMIT
R
2
Linear Data Format
2
Airflow 2 Overtemperature Fault Limit
YES
4F
HOTSPOT_2_OT_FAULT_LIMIT
R
3
Bit Flags
1
Hotspot 2 Overtemperature Fault Limit
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 3 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code
(Hex)
Command Name
Read/
Write
Page
Format
Number of
Bytes
50
AIRFLOW_1_OT_FAULT_RESPONSE
R
0
Bit Flags
1
50
HOTSPOT_1_OT_FAULT_RESPONSE
R
1
Bit Flags
1
50
AIRFLOW_2_OT_FAULT_RESPONSE
R
2
Bit Flags
1
50
HOTSPOT_2_OT_FAULT_RESPONSE
R
3
Bit Flags
2
Bit(s)
Number
Bit Name
Definition
Supported
51
AIRFLOW_1_OT_WARN_LIMIT
R
0
Linear Data Format
2
Airflow 1 Overtemperature Fault Response
Actions
Hotspot 1 Overtemperature Fault
Response Actions
Airflow 2 Overtemperature Fault Response
Actions
Hotspot 2 Overtemperature Fault
Response Actions
Airflow 1 Overtemperature Warning Limit
51
HOTSPOT_1_OT_WARN_LIMIT
R
1
Linear Data Format
2
Hotspot 1 Overtemperature Warning Limit
YES
51
AIRFLOW_2_OT_WARN_LIMIT
R
2
Linear Data Format
2
Airflow 2 Overtemperature Warning Limit
YES
51
HOTSPOT_2_OT_WARN_LIMIT
R
3
Linear Data Format
2
Hotspot 2 Overtemperature Warning Limit
YES
55
VIN_OV_FAULT_LIMIT
R
0
Bit Flags
1
Input Overvoltage Fault Limit
YES
56
VIN_OV_FAULT_RESPONSE
R
0
Linear Data Format
2
Input Overvoltage Fault Response Actions
YES
57
VIN_OV_WARN_LIMIT
R
0
Linear Data Format
2
Input Overvoltage Warning Limit
YES
58
VIN_UV_WARN_LIMIT
R
0
Linear Data Format
2
Input Undervoltage Warning Limit
YES
59
VIN_UV_FAULT_LIMIT
R
0
Linear Data Format
1
Input Undervoltage Fault Limit
YES
Linear Data Format
See Returned Data Tables for
Individual Models
#HB4xCcomcodex50
#HB3xCcomcodex50
YES
YES
YES
YES
YES
5A
VIN_UV_FAULT_RESPONSE
R
0
5B
IIN_OC_FAULT_LIMIT
R
0
Bit Flags
1
Input Undervoltage Fault Response
Actions
Input Overcurrent Fault Limit
5C
IIN_OC_FAULT_RESPONSE
R
0
Linear Data Format
2
Input Overcurrent Fault Response Actions
YES
5D
IIN_OC_WARN_LIMIT
R
0
Linear Data Format
2
Input Overcurrent Warning Limit
YES
5E
POWER_GOOD_ON
R
0
Linear Data Format
2
Power Good On Main Output Voltage Limit
YES
5F
POWER_GOOD_OFF
R
0
Linear Data Format
2
Power Good Off Main Output Voltage Limit
YES
YES
YES
2
68
POUT_OP_FAULT_LIMIT
R
0
Bit Flags
1
Output Overpower Fault Limit
69
POUT_OP_FAULT_RESPONSE
R
0
Linear Data Format
2
Output Overpower Fault Response Actions
6A
POUT_OP_WARN_LIMIT
R
1
Linear Data Format
2
6B
PIN_OP_WARN_LIMIT
R
0
Linear Data Format
2
Output Overpower Warning Limit - Low
line
Input Overpower Warning Limit - High line
0
1
2
3
79
STATUS_BYTE
R
All
Bit Flags
1
4
5
6
7
NONE_F_W
CML_F
TEMPERATURE_F_W
INPUT_UV_F
OUTPUT_OC_F
OUTPUT_OV_F
UNIT_OFF
BUSY_F
Set when a fault not listed in [7:1]
occurred
Set when a communications, memory, or
logic fault has occurred
Set when an overtemperature fault or
warning has occurred
Set when an input undervoltage fault has
occurred
Set when an output overcurrent fault has
occurred
Set when an output overvoltage fault has
occurred
Set when unit not providing power to the
output
Asserted when device busy and unable to
respond fault
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 4 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code
(Hex)
Command Name
Read/
Write
Page
Format
Number of
Bytes
Bit(s)
Number
0
1
2
3
4
5
6
7
79
STATUS_WORD
R
All
Bit Flags
2
8
9
10
11
12
13
14
15
7A
7A
STATUS_VOUT
STATUS_VSTBY
R
R
0
1
Bit Flags
Bit Flags
1
1
Bit Name
Definition
NONE_F_W
Set when a fault not listed in [7:1]
occurred
Set when a communications, memory,
or logic fault has occurred
Set when an overtemperature fault or
warning has occurred
Set when an input undervoltage fault
has occurred
Set when an output overcurrent fault
has occurred
Set when an output overvoltage fault
has occurred
Set when unit not providing power to
the output
Asserted when device busy and unable
to respond fault
Set when a fault not listed in [15:1] has
occurred
Set when a bit in command
STATUS_OTHER set
Set when a fan fault or warning has
occurred
Set when the POWER_GOOD signal is
negated
Manufacturer specific fault or warning
has occurred
Set when an Input
voltage/current/power fault or warning
has occurred
Set when an output current / output
power fault or warning has occurred
Set when an output voltage fault or
warning has occurred
Set when an error in the output voltage
during power-up/down has occurred
Set when the output turn-on timing has
exceeded the TON_MAX warning timing
Set when the output turn-on timing has
exceeded the TON_MAX fault timing
Set when the output is set higher than
the commanded VOUT_MAX limit
Set when an output undervoltage fault
has occurred
Set when an output undervoltage
warning has occurred
Set when an output overvoltage warning
has occurred
Set when an output overvoltage fault
has occurred
Set when an error in the output voltage
during power-up/down has occurred
Set when the output turn-on timing has
exceeded the TON_MAX warning timing
Set when the output turn-on timing has
exceeded the TON_MAX fault timing
Set when the output is set higher than
the commanded VOUT_MAX limit
Set when an output undervoltage fault
has occurred
Set when an output under-voltage
warning has occurred
Set when an output overvoltage warning
has occurred
Set when an output overvoltage fault
has occurred
CML_F
TEMPERATURE_F_W
INPUT_UV_F
OUTPUT_OC_F
OUTPUT_OV_F
UNIT_OFF
BUSY_F
UNKNOWN_F_W
STATUS_OTHER_F_W
FANS_F_W
POWER_GOOD_L
MFG_SPECIFIC_F_W
INPUT_F_W
IOUT_POUT_F_W
VOUT_F_W
0
VOUT_TRACKING_E
1
TON_MAX_W
2
TON_MAX_F
3
VOUT_MAX_F
4
VOUT_UV_F
5
VOUT_UV_W
6
VOUT_OV_W
7
VOUT_OV_F
0
VOUT_TRACKING_E
1
TON_MAX_W
2
TON_MAX_F
3
VOUT_MAX_F
4
VOUT_UV_F
5
VOUT_UV_W
6
VOUT_OV_W
7
VOUT_OV_F
Supported
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 5 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code
(Hex)
7B
Command Name
STATUS_IOUT
Read/
Write
R
Page
0
Format
Bit Flags
Number of
Bytes
1
Bit(s)
Number
0
Bit Name
Definition
Supported
POUT_OP_W
POUT_OP_F
2
POWER_LIMIT_MODE
3
CURRENT_SHARE_F
4
IOUT_UC_W
Set when an output overpower warning
has occurred
Set when an output overpower fault has
occurred
Set when the unit has entered output
power limiting mode
Set when an output current share fault
has occurred
Set when an output undercurrent fault
has occurred
Set when an output overcurrent warning
has occurred
Set when an output overcurrent and low
voltage shutdown fault has occurred
Set when an output overcurrent fault
has occurred
Set when an output overpower warning
has occurred
Set when an output overpower fault has
occurred
Set when the unit has entered output
power limiting mode
Set when an output current share fault
has occurred
Set when an output undercurrent fault
has occurred
Set when an output overcurrent warning
has occurred
Set when an output overcurrent and low
voltage shutdown fault has occurred
Set when an output overcurrent fault
has occurred
Set when an input overpower warning
has occurred
Set when an input overcurrent warning
has occurred
Set when an input overcurrent fault has
occurred
Set when the Unit is OFF for insufficient
input voltage
Set when an input undervoltage fault
has occurred
Set when an input undervoltage warning
has occurred
Set when an input overvoltage warning
has occurred
Set when an input overvoltage fault has
occurred
YES
1
5
IOUT_OC_W
6
IOUT_OC_SHUTDOWN
7
IOUT_OC_F
0
POUT_OP_W
1
2
3
7B
STATUS_ISTBY
R
1
Bit Flags
1
4
5
6
7
7C
7D
STATUS_INPUT
STATUS-TEMPERATURE
R
R
ALL
ALL
Bit Flags
Bit Flags
R
All
Bit Flags
CURRENT_SHARE_F
IOUT_UC_W
IOUT_OC_W
IOUT_OC_SHUTDOWN
IOUT_OC_F
NO
YES
YES
YES
YES
YES
NO
NO
NO
YES
YES
YES
YES
1
IIN_OC_W
2
IIN_OC_F
3
VIN_UV_OFF
4
VIN_UV_F
5
VIN_UV_W
6
VIN_OV_W
7
VIN_OV_F
0
RESERVED
Reserved
NO
1
RESERVED
Reserved
NO
2
RESERVED
Reserved
NO
3
RESERVED
Reserved
NO
Set when an undertemperature fault has
occurred
Set when an undertemperature warning
has occurred
Set when an overtemperature warning
has occurred
Set when an overtemperature fault has
occurred
Set when another memory or logic fault
has occurred
Set when a communication fault not
listed in [7:3] has occurred (example:
UART or SPI)
NO
1
1
NO
PIN_OP_W
4
TEMPERATURE_UT_F
5
TEMPERATURE_UT_W
6
TEMPERATURE_OT_W
7
TEMPERATURE_OT_F
1
STATUS_CML
POWER_LIMIT_MODE
NO
0
0
7E
POUT_OP_F
YES
OTHER_MEMORY_F
OTHER_COMM_F
YES
YES
NO
NO
YES
YES
YES
NO
YES
YES
NO
YES
2
RESERVED
Reserved
NO
3
PROCESSOR_F
Set when a processor fault is detected
NO
MEMORY_F
Set when a memory fault is detected
(example: Checksum errors during
bootload)
Set when a packet error checking (PEC)
failed has occurred
Set when invalid or unsupported data is
received
Set when an invalid or unsupported
command is received
NO
1
4
5
6
7
PEC_ERROR_F
DATA_ERROR_F
COMMAND_ERROR_F
YES
YES
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 6 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code
(Hex)
Command Name
Read/Wri
te
Page
Format
Number of
Bit(s) Number
Bytes
0
1
2
Bit Name/Comment
Description
Supported
RESERVED
RESERVED
NO
NO
81
STATUS_FANS_1_2
R
All
Bit Flags
1
88
READ_VIN
R
All
Linear Data Format
2
Reserved
Reserved
Set when an internal voltage (VCC2,
VCC4, or VDD) out-of-range warning
has occurred
Set when an internal voltage (VCC2,
VCC4, or VDD) out-of-range fault has
occurred
Set when the primary boost output
bus undervoltage fault has occurred
Set when the primary boost output
bus undervoltage warning has
occurred
Set when the primary boost output
bus overvoltage warning has
occurred
Set when the primary boost output
bus overvoltage fault has occurred
Airflow warning
Airflow fault
Fan 2 speed overridden
Fan 1 speed overridden
Fan 2 warning
Fan 1 warning
Fan 2 fault
Fan 1 fault
Input Voltage Sensor Reading
89
READ_IIN
R
All
Linear Data Format
2
Input Current Sensor Reading
YES
8B
READ_VOUT
R
0
Direct Data Format
2
Main Output Voltage Sensor Reading
YES
8B
READ_VSTBY
R
1
Direct Data Format
2
8C
READ_IOUT
R
0
Direct Data Format
2
3
80
STATUS_MFR_SPECIFIC
R
All
Bit Flags
1
4
5
6
7
0
1
2
3
4
5
6
7
VINT_RANGE_W
VINT_RANGE_F
VBUS_UV_F
VBUS_UV_W
VBUS_OV_W
VBUS_OV_F
FAN_AIRFLOW_W
FAN_AIRFLOW_F
FAN_2_OVERRIDE
FAN_1_OVERRIDE
FAN_2_W
FAN_1_W
FAN_2_F
FAN_1_F
Standby(Auxiliary) Output Voltage
Sensor Reading
Main Output Current Sensor Reading
NO
YES
YES
YES
YES
YES
NO
NO
NO
YES
NO
YES
NO
YES
YES
YES
YES
8F
READ_TEMPERATURE_3
R
1
Linear Data Format
2
90
READ_FAN_SPEED_1
R
0
Linear Data Format
2
Standby(Auxiliary) Output Current
Sensor Reading
Temperature Sensor Reading - Inlet
(Secondary Side)
Temperature Sensor Reading - Outlet
(Primary Side)
Temperature Sensor Reading - Main
Output Hotspot (Secondary Side)
Temperature Sensor Reading - PFC
Hotspot (Primary Side)
Fan 1 Speed Sensor Reading
91
READ_FAN_SPEED_2
R
0
Linear Data Format
2
Fan 2 Speed Sensor Reading
NO
96
READ_POUT
R
All
Linear Data Format
2
Output Power Sensor Reading
YES
97
READ_PIN
R
All
Linear Data Format
2
Input Power Sensor Reading
YES
98
PMBUS_REVISION
R
ALL
HEX
1
PMBus Specification Revision
YES
99
MFR_ID
R
All
Ascii Text Block
Variable
8C
READ_ISTBY
R
1
Direct Data Format
2
8D
READ_TEMPERATURE_1
R
0
Linear Data Format
2
8E
READ_TEMPERATURE_2
R
0
Direct Data Format
2
8F
READ_TEMPERATURE_3
R
0
Linear Data Format
2
9A
MFR_PART_NUMBER
R
All
Ascii Text Block
15
9B
MFR_REVISION
R
All
Ascii Text Block
10
9C
MFR_LOCATION
R/W
All
Ascii Text Block
Variable
9D
MFR_DATE
R/W
All
Ascii Text Block
5
9E
MFR_SERIAL
R/W
All
Ascii Text Block
2
See Sensor Data Tables
for All Models
#SensorDataxHB4xC
#SensorDataxHB3xC
See MFR_ID at link:
#ComCodex99
See MFR_PART_NUMBER at link:
#ComCodex9M1845
#ComCodex9AHB4BCAB
ComCodex9AHB4C
ComCodex9AHB4CJBL
ComCodex9AHC3BCAB
ComCodex9AH3BC
See MFR_REVISION at link:
#ComCodex9B
See MFR_LOCATION at link:
#ComCodex9C
See MFR_DATE at link:
ComCodex9D
See MFR_SERIAL at link:
#ComCodex9E
Power Supply Company Name
YES
YES
YES
YES
YES
YES
YES
Power Supply Firmware Revision
YES
Power Supply Model Number
Power Supply Manufacture Location
Power Supply Manufacture Date
Power Supply Serial Number
YES
YES
YES
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 7 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command
Code (Hex)
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
Command Name
Read/
Write
Page
Format
Number of
Bit(s)
Bytes
Number
MFR_VIN_MIN
R
All
Linear Data Format
2
MFR_VIN_MAX
R
All
Linear Data Format
2
MFR_IIN_MAX
R
All
Linear Data Format
2
MFR_PIN_MAX
R
All
Linear Data Format
2
MFR_VOUT_MIN
R
All
Linear Data Format
2
MFR_VOUT_MAX
R
All
Linear Data Format
2
MFR_IOUT_MAX
R
All
Linear Data Format
2
MFR_POUT_MAX
R
All
Linear Data Format
2
MFR_TAMBIENT_MAX
R
All
Linear Data Format
2
MFR_TAMBIENT_MIN
R
All
Linear Data Format
2
Bit Name/Comment
See Manufacturers Data Tables
ComCodexA0
AA
AB
MFR_EFFICIENCY_LL
MFR_EFFICIENCY_HL
R
R
All
All
Linear Data Format
Linear Data Format
2
2
0
E0
PS_STATUS
(Non-sticky" Power Supply Status Bits)
R
All
Bit Flags
2
CALIBRATION
1
VSTBY_SELECT
2
PS_KILL
Description
Power Supply Input Voltage Minimum
Specification
Power Supply Input Voltage Maximum
Specification
Power Supply Input Current Maximum
Specification
Power Supply Input Power Maximum
Specification
Power Supply Main Output Voltage
Minimum Specification
Power Supply Main Output Voltage
Maximum Specification
Power Supply Main Output Current
Maximum Specification
Power Supply Output Power Maximum
Specification
Power Supply Operating Ambient
Temperature Maximum Specification
Power Supply Operating Ambient
Temperature Minimum Specification
Power Supply High-Line Low Power
Specification
Power Supply High-Line Low Power
Efficiency Specification
Power Supply High-Line Medium Power
Specification
Power Supply High-Line Medium Power
Efficiency Specification
Power Supply High-Line High Power
Specification
Power Supply High-Line Low Power
Specification
Power Supply High-Line Low Power
Efficiency Specification
Power Supply High-Line Input Voltage
Specification
Power Supply High-Line Low Power
Specification
Power Supply High-Line Low Power
Efficiency Specification
Power Supply High-Line Medium Power
Specification
Power Supply High-Line Medium Power
Efficiency Specification
Power Supply High-Line High Power
Specification
Set when the unit is in Calibration mode
Set when Vstby set to 5V; de-set when
Vstby set to 3.3V
Set when the PS_KILL pin is defeated
and the unit is properly seated in the
chassis
Set when the input voltage is within
operating specification
Set when input voltage range is high;
de-set when input voltage range is low
Set when the PFC Bus is within
operating specification
Set when the PS_ON logic set to enable
the main output
Set when main output power delivered
by the unit is OK; mirrors the digital
output signal
Set when boot loader is taking control
and the main output and PFC need to
be shutdown
Set when the boot loader has
completed and system reset needs to
be Set
Supported
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
3
VIN_OK
4
VIN_RANGE
5
PFC_BUS
6
PS_ON
7
POWER_GOOD
8
POWER_DOWN
9
BOOTLOAD_COMPLETED
10
UNUSED
NO
11
12
13
UNUSED
UNUSED
UNUSED
NO
NO
NO
14
WARNING
15
FAULT
Set when power supply warning has
occurred; tracks 'WARNING' status LED
Set when power supply fault has
occurred; tracks 'FAULT' status LED
YES
YES
YES
YES
YES
YES
YES
YES
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 8 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command
Code (Hex)
Command Name
Read/Write Page
Format
Number of
Bit(s)
Bytes
Number
Bit Name/Comment
E1
EEPROM_WP
R/W
All
Integer
1
See EEPROM FRU Data
EEPROMDATAHB4C
EEPROMDATAHB3C
E2
READ_HOURS_USED
R
All
Linear Data Format
3
See Sensor Data Tables for
Individual Models
ComCodexE2HB4xCxxx
ComCodexE2HB3xCxxx
Bit Flags
2
E5
READ_RESETS
R
All
Bit Flags
2
EE
EF
PMBUS_CONFIG
PMBUSCONFIG
LED_CONTROL
R
R
All
All
Bit Flags
Bit Flags
2
1
0
DATA_FORMAT
1
SMBALERT_L
2
MAX_BUS_SPEED
3
PEC
4:7
RESERVED
8:15
CMD_KEY
0:2
3:6
LED_MODE
RESERVED
LED_CONTROL
ComCodexEF
7
F0
READ_RESETS
R
Bit Flags
2
Bit Flags
2
All
F8
BOOTLOAD_RESTART
R/W
All
HEX
1
FA
BOOTLOADER_REQUEST
R/W
All
Ascii Text Block
6
FB
BOOTLOADER-STATUS
R
All
Bit Flags
2
0
BOOTLOADING_PRI
1
BOOTLOADING_FLOAT
2
BOOTLOADING_SEC
3
BOOTLOADED_PRI
4
BOOTLOADED_FLOAT
5
BOOTLOADED_SEC
6
RESET_PRI
7
RESET_FLOAT
Description
Write 0x9A to enable write protection
to the external EEPROM.
Write 0x56 to disable write protection
to the external EEPROM
Power Supply Accumulated Main
Output Power-On Hours
RCON register status flags for
troubleshooting
RCON2 register status flags for
troubleshooting
0 = Linear data format 1 = Direct
data format
0 = SMBALERT_L implemented &
supported 1 = SMBALERT not
implemented
0 = 100kHz 1 = 400kHz
0 = PEC not supported 1 = PEC
supported
Supported
YES
YES
YES
YES
YES
NO
NO
YES
NO
Command activation/verification key
= 0x5A
LED mode change bits
LED manual/auto control
toggle bit
RCON register status flags for
troubleshooting
RCON2 register status flags for
troubleshooting
Boot loader completion and
application restart request command
Boot loader request command
Set when primary uC bootloading in
process
Set when floating uC bootloading in
process
Set when secondary uC bootloading
in process
Set when primary uC bootloading
completed; reset required
Set when floating uC bootloading
completed; reset required
Set when secondary uC bootloading
completed; reset required
Set when primary uC reset
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Set when floating uC reset
YES
Set when secondary uC reset
YES
8
RESET_SEC
9
RESERVED
NO
10
RESERVED
NO
11
RESERVED
NO
12
RESERVED
NO
13
RESERVED
NO
14
RESERVED
NO
15
RESERVED
NO
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 9 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
RETURNED RESULTS (VS. COMMAND CODE):
The following table represents typical results/responses returned from respective Command Code entries and is provided as an illustration of what should be expected.
RETURNED RESULTS: M1845 & D1U54P-W-650-12-HB4xC-xxx; Back to Front Airflow: 12VSB (M1845; M1871, M1876)
Command
Code Hex)
Command Name
Read/
Write
Page
Data
Format
# of
Bytes
Units
Scaling Coefficients
N
40
VOUT_OV_FAULT_LIMIT
R
0
Linear Data Format
2
Vdc
-6
40
VSTBY_OV_FAULT_LIMIT
R
1
Linear Data Format
2
Vdc
-6
41
VOUT_OV_FAULT_RESPONSE
R
0
Bit Flags
1
41
VSTBY_OV_FAULT_RESPONSE
R
1
Bit Flags
1
m
R
Bit #
Reading
b
14
14
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
42
VOUT_OV_WARN_LIMIT
R
0
Linear Data Format
2
Vdc
-6
13.5
42
VSTBY_OV_WARN_LIMIT
R
1
Linear Data Format
2
Vdc
-6
13.5
43
VOUT_UV_WARN_LIMIT
R
0
Linear Data Format
2
Vdc
-6
11.4
43
VSTBY_UV_WARN_LIMIT
R
1
Linear Data Format
2
Vdc
-6
11.3
44
VOUT_UV_FAULT_LIMIT
R
0
Linear Data Format
2
Vdc
-6
10.9
44
VSTBY_UV_FAULT_LIMIT
R
1
Linear Data Format
2
Vdc
-6
45
VOUT_UV_FAULT_RESPONSE
R
0
Bit Flags
1
45
VSTBY_UV_FAULT_RESPONSE
R
1
Bit Flags
1
46
IOUT_OC_FAULT_LIMIT
R
0
Linear Data Format
2
Adc
-4
46
ISTBY_OC_FAULT_LIMIT
R
1
Linear Data Format
2
Adc
-8
47
IOUT_OC_FAULT_RESPONSE
R
0
Bit Flags
1
47
4A
ISTBY_OC_FAULT_RESPONSE
R
1
Bit Flags
1
Comments
11.1
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
63
3
2:0
0
Delay Time - None
5:3
7
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Continuous restart (self-recovery)
2:0
0
Delay Time - None
5:3
7
Response - Continuous restart (self-recovery)
7:6
3
Response - Output disabled while fault is present
& remains disabled until fault cleared
IOUT_OC_WARN_LIMIT
R
0
Linear Data Format
2
Adc
-4
60
4A
ISTBY_OC_WARN_LIMIT
R
1
Linear Data Format
2
Adc
-8
2.7
4F
AIRFLOW_1_OT_FAULT_LIMIT
R
0
Linear Data Format
2
°C
0
95
Primary Airflow – Outlet (exhaust)
4F
HOTSPOT_1_OT_FAULT_LIMIT
R
1
Linear Data Format
2
°C
0
120
Primary Hotspot - PFC
4F
AIRFLOW_2_OT_FAULT_LIMIT
R
2
Linear Data Format
2
°C
0
75
Secondary Airflow – Inlet
4F
HOTSPOT_2_OT_FAULT_LIMIT
R
3
Linear Data Format
2
°C
0
130
Secondary Hotspot – Main Transformer
#Backtox40
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 10 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
RETURNED RESULTS: M1845 & D1U54P-W-650-12-HB4xC-xxx; Back to Front Airflow: 12VSB (M1845; M1871, M1876, )
Command
Code Hex)
Command Name
Read/
Write
Page
Data
Format
# of
Bytes
50
AIRFLOW_1_OT_FAULT_RESPONSE
R
0
Bit Flags
1
Units
Scaling Coefficients
N
50
50
50
HOTSPOT_1_OT_FAULT_RESPONSE
AIRFLOW_2_OT_FAULT_RESPONSE
HOTSPOT_2_OT_FAULT_RESPONSE
R
R
R
1
2
3
Bit Flags
Bit Flags
Bit Flags
1
1
1
m
R
Bit #
Reading
Comments
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
2:0
0
5:3
0
7:6
3
2:0
0
5:3
0
7:6
3
b
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
51
AIRFLOW_1_OT_WARN_LIMIT
R
0
Linear Data Format
2
°C
0
85
Primary Airflow - Outlet
51
HOTSPOT_1_OT_WARN_LIMIT
R
1
Linear Data Format
2
°C
0
110
Primary Hotspot - PFC
51
AIRFLOW_2_OT_WARN_LIMIT
R
2
Linear Data Format
2
°C
0
70
Secondary Airflow - Inlet
51
HOTSPOT_2_OT_WARN_LIMIT
R
3
Linear Data Format
2
°C
0
110
Secondary Hotspot - Main output hotspot
55
VIN_OV_FAULT_LIMIT
R
0
Linear Data Format
2
Vrms
-1
275
Recoverable
56
VIN_OV_FAULT_RESPONSE
R
0
Bit Flags
1
2:0
0
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
57
VIN_OV_WARN_LIMIT
R
0
Linear Data Format
2
Vrms
-1
270
58
VIN_UV_WARN_LIMIT
R
0
Linear Data Format
2
Vrms
-1
80
59
VIN_UV_FAULT_LIMIT
R
0
Linear Data Format
2
Vrms
-1
5A
VIN_UV_FAULT_RESPONSE
R
0
Bit Flags
1
5B
IIN_OC_FAULT_LIMIT
R
0
Linear Data Format
2
5C
IIN_OC_FAULT_RESPONSE
R
0
Bit Flags
1
Arms
73
2:0
0
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
-6
12.2
2:0
0
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
5D
IIN_OC_WARN_LIMIT
R
0
Linear Data Format
2
Arms
-6
11.2
5E
POWER_GOOD_ON
R
0
Linear Data Format
2
Vdc
-6
10.9
5F
POWER_GOOD_OFF
R
0
Linear Data Format
2
Vdc
-6
10.9
68
POUT_OP_FAULT_LIMIT
R
0
Linear Data Format
2
Watts
0
69
POUT_OP_FAULT_RESPONSE
R
0
Bit Flags
1
760
2:0
0
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
6A
POUT_OP_WARN_LIMIT
R
0
Linear Data Format
2
Watts
0
720
6B
PIN_OP_WARN_LIMIT
R
0
Linear Data Format
2
Watts
0
900
#Backtox50
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 11 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
RETURNED RESULTS: D1U54P-W-650-12-HB3xC-xxx; Front to Back Airflow: 12VSB (M1872, M1877)
Command
Code Hex)
Command Name
Read/
Write
Page
Data
Format
# of
Bytes
Units
40
VOUT_OV_FAULT_LIMIT
R
40
VSTBY_OV_FAULT_LIMIT
41
VOUT_OV_FAULT_RESPONSE
Scaling Coefficients
0
Linear Data Format
2
Vdc
-6
R
1
Linear Data Format
2
Vdc
-6
R
0
Bit Flags
1
N
41
VSTBY_OV_FAULT_RESPONSE
R
1
Bit Flags
1
m
R
Bit #
Reading
b
14
14
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
42
VOUT_OV_WARN_LIMIT
R
0
Linear Data Format
2
Vdc
-6
13.5
42
VSTBY_OV_WARN_LIMIT
R
1
Linear Data Format
2
Vdc
-6
13.5
43
VOUT_UV_WARN_LIMIT
R
0
Linear Data Format
2
Vdc
-6
11.4
43
VSTBY_UV_WARN_LIMIT
R
1
Linear Data Format
2
Vdc
-6
11.3
44
VOUT_UV_FAULT_LIMIT
R
0
Linear Data Format
2
Vdc
-6
10.9
44
VSTBY_UV_FAULT_LIMIT
R
1
Linear Data Format
2
Vdc
-6
45
VOUT_UV_FAULT_RESPONSE
R
0
Bit Flags
1
45
VSTBY_UV_FAULT_RESPONSE
R
1
Bit Flags
1
46
IOUT_OC_FAULT_LIMIT
R
0
Linear Data Format
2
Adc
-4
46
ISTBY_OC_FAULT_LIMIT
R
1
Linear Data Format
2
Adc
-8
47
IOUT_OC_FAULT_RESPONSE
R
0
Bit Flags
1
47
ISTBY_OC_FAULT_RESPONSE
R
1
Bit Flags
1
Comments
11.1
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
63
3
2:0
0
Delay Time - None
5:3
7
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Continuous restart (self-recovery)
2:0
0
Delay Time - None
5:3
7
Response - Continuous restart (self-recovery)
7:6
3
Response - Output disabled while fault is present
& remains disabled until fault cleared
4A
IOUT_OC_WARN_LIMIT
R
0
Linear Data Format
2
Adc
-4
60
4A
ISTBY_OC_WARN_LIMIT
R
1
Linear Data Format
2
Adc
-8
2.7
4F
AIRFLOW_1_OT_FAULT_LIMIT
R
0
Linear Data Format
2
°C
0
75
Primary Airflow - Inlet
4F
HOTSPOT_1_OT_FAULT_LIMIT
R
1
Linear Data Format
2
°C
0
120
Primary Hotspot - PFC
4F
AIRFLOW_2_OT_FAULT_LIMIT
R
2
Linear Data Format
2
°C
0
95
Secondary Airflow - Outlet
4F
HOTSPOT_2_OT_FAULT_LIMIT
R
3
Linear Data Format
2
°C
0
130
Secondary Hotspot - Main output hotspot
#Backtox40
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 12 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
RETURNED RESULTS: D1U54P-W-650-12-HB3xC-xxx; Front to Back Airflow: 12VSB (M1872, M1877)
Command
Code Hex)
Command Name
Read/
Write
Page
Data
Format
# of
Bytes
50
AIRFLOW_1_OT_FAULT_RESPONSE
R
0
Bit Flags
1
Units
Scaling Coefficients
N
50
50
50
HOTSPOT_1_OT_FAULT_RESPONSE
AIRFLOW_2_OT_FAULT_RESPONSE
HOTSPOT_2_OT_FAULT_RESPONSE
R
R
R
1
2
3
Bit Flags
Bit Flags
Bit Flags
1
1
1
m
R
Bit #
Reading
Comments
2:0
0
Delay Time - None
5:3
0
7:6
3
2:0
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
5:3
0
7:6
3
2:0
0
5:3
0
7:6
3
2:0
0
5:3
0
7:6
3
b
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Delay Time - None
51
AIRFLOW_1_OT_WARN_LIMIT
R
0
Linear Data Format
2
°C
0
70
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Primary Airflow - Inlet
51
HOTSPOT_1_OT_WARN_LIMIT
R
1
Linear Data Format
2
°C
0
110
Primary Hotspot - PFC
51
AIRFLOW_2_OT_WARN_LIMIT
R
2
Linear Data Format
2
°C
0
85
Secondary Airflow - Outlet
51
HOTSPOT_2_OT_WARN_LIMIT
R
3
Linear Data Format
2
°C
0
110
Secondary Hotspot - Main output hotspot
55
VIN_OV_FAULT_LIMIT
R
0
Linear Data Format
2
Vrms
-1
275
Recoverable
56
VIN_OV_FAULT_RESPONSE
R
0
Bit Flags
1
2:0
0
Delay Time - None
5:3
0
7:6
3
57
VIN_OV_WARN_LIMIT
R
0
Linear Data Format
2
Vrms
-1
270
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
Recoverable
58
VIN_UV_WARN_LIMIT
R
0
Linear Data Format
2
Vrms
-1
80
Recoverable
59
VIN_UV_FAULT_LIMIT
R
0
Linear Data Format
2
Vrms
-1
73
Recoverable
5A
VIN_UV_FAULT_RESPONSE
R
0
Bit Flags
1
2:0
0
Delay Time - None
5:3
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
7:6
5B
IIN_OC_FAULT_LIMIT
R
0
Linear Data Format
2
5C
IIN_OC_FAULT_RESPONSE
R
0
Bit Flags
1
Arms
-6
3
12.2
2:0
0
Delay Time - None
5:3
0
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
7:6
3
5D
IIN_OC_WARN_LIMIT
R
0
Linear Data Format
2
Arms
-6
11.2
5E
POWER_GOOD_ON
R
0
Linear Data Format
2
Vdc
-6
10.9
10.9
5F
POWER_GOOD_OFF
R
0
Linear Data Format
2
Vdc
-6
68
POUT_OP_FAULT_LIMIT
R
0
Linear Data Format
2
Watts
0
69
POUT_OP_FAULT_RESPONSE
R
0
Bit Flags
1
760
2:0
0
Delay Time - None
5:3
0
7:6
3
Retry Setting - Unit does not attempt to restart &
output remains disabled until fault clear
Response - Output disabled while fault is present
& remains disabled until fault cleared
6A
POUT_OP_WARN_LIMIT
R
0
Linear Data Format
2
Watts
0
720
6B
PIN_OP_WARN_LIMIT
R
0
Linear Data Format
2
Watts
0
900
#Backtox50
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 13 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
SENSOR DATA AND RESOLUTION
SENSOR DATA: M1845 & D1U54P-W-1200-12-HB4xC-xxx; Back to Front Airflow: 12VSB (M1845; M1871, M1876, )
Command
Code (Hex)
Command Name
Description
Page
88
READ_VIN
Input Voltage Sensor Reading
All
89
READ_IIN
Input Current Sensor Reading
All
8B
READ_VOUT
8B
READ_VSTBY
8C
READ_IOUT
8C
READ_ISTBY
8D
READ_TEMPERATURE_1
8E
READ_TEMPERATURE_2
8F
READ_TEMPERATURE_3
8F
READ_TEMPERATURE_3
90
READ_FAN_SPEED_1
96
97
#Backtox88
E2
#BacktoxE2
READ_POUT
READ_PIN
READ_POWER_ON_HOURS
Main Output Voltage Sensor
Reading
Standby(Auxiliary) Output
Voltage Sensor Reading
Main Output Current Sensor
Reading
Standby(Auxiliary) Output
Current Sensor Reading
Temperature Sensor Reading Inlet (Secondary Side)
Temperature Sensor Reading Outlet (Primary Side)
Temperature Sensor Reading Main Output Hotspot (Secondary
Side)
Temperature Sensor Reading PFC Hotspot (Primary Side)
Fan 1 Speed Sensor Reading
Output Power Sensor Reading
Input Power Sensor Reading
Input Voltage Sensor Reading
0
1
0
1
0
0
0
1
All
All
All
All
Data
Format
Linear Data
Format
Linear Data
Format
Direct Data
Format
Direct Data
Format
Direct Data
Format
Direct Data
Format
Linear Data
Format
Direct Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Scaling
Coefficient
Units
N
m
R
Raw Sensor
b
PMBus Reporting Sensor
Full-scale /
Full-scale / Range Resolution
Range
327.93
0.3206
511.5
Resolution
Accuracy
0.5
+ / - 2% of Reporting Full-Scale
0.0156
+ / - 5% of Reporting Full-Scale
15.98
0.0156
+ / - 2% of Reporting Full-Scale
15.984
0.01563
+ / - 2% of Reporting Full-Scale
63.94
0.063
+ / - 2% of Reporting Full-Scale
3.996
0.00391
+ / - 2% of Reporting Full-Scale
-40 to 150
-40 to 150
1
+ / - 5°C
-40 to 150
-40 to 150
1
+ / - 5°C
0
-40 to 150
-40 to 150
1
+ / - 5°C
°C
0
-40 to 150
-40 to 150
1
+ / - 5°C
24,000
32736
32
+ / - 5% of Reporting Full-Scale
1023
1
+ / - 5% of Reporting Full-Scale
1023
1
+ / - 5% of Reporting Full-Scale
~1,900
(Years)
1
+ / - 3%
Vrms
-1
Arms
-6
17.86
0.0175
Vdc
-6
14.79
0.0145
Vdc
-6
14.73
0.0144
Adc
-4
70.77
0.0692
Adc
-8
4.33
0.0042
°C
0
°C
0
°C
RPM
5
Watts
0
Watts
0
Hours
0
~1,900 (Years)
15.98
SENSOR DATA: D1U54P-W-1200-12-HB3xC-xxx; Front to Back Airflow: 12VSB (M1872, M1877)
Command
Code (Hex)
Command Name
Description
Page
88
READ_VIN
Input Voltage Sensor Reading
All
READ_IIN
Input Current Sensor Reading
All
READ_VOUT
0
READ_FAN_SPEED_1
Main Output Voltage Sensor
Reading
Standby(Auxiliary) Output Voltage
Sensor Reading
Main Output Current Sensor
Reading
Standby(Auxiliary) Output Current
Sensor Reading
Temperature Sensor Reading Inlet (Primary Side)
Temperature Sensor Reading Outlet (Secondary Side)
Temperature Sensor Reading Main Output Hotspot (Secondary
Side)
Temperature Sensor Reading PFC Hotspot (Primary Side)
Fan 1 Speed Sensor Reading
All
READ_POUT
Output Power Sensor Reading
All
READ_PIN
Input Power Sensor Reading
All
READ_POWER_ON_HOURS
Accumulated Main Output PowerOn Hours
All
89
8B
8B
8C
8C
8D
8E
8F
8F
90
96
97
#Backtox88
E2
#BacktoxE2
READ_VSTBY
READ_IOUT
READ_ISTBY
READ_TEMPERATURE_1
READ_TEMPERATURE_2
READ_TEMPERATURE_3
READ_TEMPERATURE_3
1
0
1
0
0
0
1
Data
Format
Linear Data
Format
Linear Data
Format
Direct Data
Format
Direct Data
Format
Direct Data
Format
Direct Data
Format
Linear Data
Format
Direct Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Linear Data
Format
Scaling
Coefficient
Units
N
m
R
Raw Sensor
b
PMBus Reporting Sensor
Full-scale /
Full-scale / Range Resolution
Range
327.93
0.3206
511.5
Resolution
Accuracy
0.5
+ / - 2% of Reporting Full-Scale
15.98
0.0156
+ / - 5% of Reporting Full-Scale
15.98
0.0156
+ / - 2% of Reporting Full-Scale
0.0144
15.984
0.01563
+ / - 2% of Reporting Full-Scale
70.77
0.0692
63.94
0.063
+ / - 2% of Reporting Full-Scale
4.33
0.0042
3.996
0.00391
+ / - 2% of Reporting Full-Scale
-40 to 150
-40 to 150
1
+ / - 5°C
-40 to 150
-40 to 150
1
+ / - 5°C
0
-40 to 150
-40 to 150
1
+ / - 5°C
°C
0
-40 to 150
-40 to 150
1
+ / - 5°C
24,000
32736
32
+ / - 5% of Reporting Full-Scale
1023
1
+ / - 5% of Reporting Full-Scale
1023
1
+ / - 5% of Reporting Full-Scale
~1,900
(Years)
1
+ / - 3%
Vrms
-1
Arms
-6
17.86
0.0175
Vdc
-6
14.79
0.0145
Vdc
-6
14.73
Adc
-4
Adc
-8
°C
0
°C
0
°C
RPM
5
Watts
0
Watts
0
Hours
0
~1,900 (Years)
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 14 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
MANUFACTURERS VITAL PRODUCT DATA
Command Code 99 HEX (MAN_ID)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_ID_LENGTH
99
#Backtox99
MFR_ID
Murata-PS
N/A
9
MFR_ID_0
'M'
MFR_ID_1
'u'
MFR_ID_2
'r'
MFR_ID_3
'a'
MFR_ID_4
't'
MFR_ID_5
'a'
MFR_ID_6
'-'
MFR_ID_7
'P'
MFR_ID_8
'S'
Command Code 9A HEX; (MFR_MODEL) M1845; AC Input Variant; Back to Front Airflow
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 5
9A
#Backtox9A
MFR_MODEL
M1845
N/A
MFR_MODEL_0
'M'
MFR_MODEL_1
'1'
MFR_MODEL_2
'8'
MFR_MODEL_3
'4'
MFR_MODEL_4
‘5'
MFR_MODEL_5
Command Code 9A HEX; (MAN_MODEL) D1U54P-W-650-12-HB4BC-AB; AC Input Variant; Back to Front Airflow (M1871)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 25
MFR_MODEL_0
9A
#Backtox9A
MFR_MODEL
D1U54P-W-650-12-HB4BC-AB
N/A
'D'
MFR_MODEL_1
'1'
MFR_MODEL_2
'U'
MFR_MODEL_3
'5'
MFR_MODEL_4
'4'
MFR_MODEL_5
'P’
MFR_MODEL_6
'-'
MFR_MODEL_7
'W'
MFR_MODEL_8
‘-‘
MFR_MODEL_10
‘6’
MFR_MODEL_11
‘5’
MFR_MODEL_12
‘0’
MFR_MODEL_13
‘-’
MFR_MODEL_14
‘1‘
MFR_MODEL_15
‘2’
MFR_MODEL_16
‘-‘
MFR_MODEL_17
‘H’
MFR_MODEL_18
‘B’
MFR_MODEL_19
‘4’
MFR_MODEL_20
‘B’
MFR_MODEL_21
‘C’
MFR_MODEL_22
‘-“
MFR_MODEL_23
‘A’
MFR_MODEL_24
‘B’
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 15 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code 9A HEX; (MAN_MODEL) D1U54P-W-650-12-HB4C; DC Input Variant; Back to Front Airflow (M1876)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 21
MFR_MODEL_0
9A
#Backtox9A
MFR_MODEL
D1U54P-W-650-12-HB4C
N/A
'D'
MFR_MODEL_1
'1'
MFR_MODEL_2
'U'
MFR_MODEL_3
'5'
MFR_MODEL_4
'4'
MFR_MODEL_5
'P’
MFR_MODEL_6
'-'
MFR_MODEL_7
'W'
MFR_MODEL_8
‘-‘
MFR_MODEL_10
‘6’
MFR_MODEL_11
‘5’
MFR_MODEL_12
‘0’
MFR_MODEL_13
‘-’
MFR_MODEL_14
‘1‘
MFR_MODEL_15
‘2’
MFR_MODEL_16
‘-‘
MFR_MODEL_17
‘H’
MFR_MODEL_18
‘B’
MFR_MODEL_19
‘4’
MFR_MODEL_20
'C'
Command Code 9A HEX; (MAN_MODEL) D1U54P-W-650-12-HB3BC-AB; AC Input Variant; Front to Back Airflow (M1872)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 25
MFR_MODEL_0
9A
#Backtox9A
MFR_MODEL
D1U54P-W-650-12-HB3BC-AB
N/A
'D'
MFR_MODEL_1
'1'
MFR_MODEL_2
'U'
MFR_MODEL_3
'5'
MFR_MODEL_4
'4'
MFR_MODEL_5
'P’
MFR_MODEL_6
'-'
MFR_MODEL_7
'W'
MFR_MODEL_8
‘-‘
MFR_MODEL_10
‘6’
MFR_MODEL_11
‘5’
MFR_MODEL_12
‘0’
MFR_MODEL_13
‘-’
MFR_MODEL_14
‘1‘
MFR_MODEL_15
‘2’
MFR_MODEL_16
‘-‘
MFR_MODEL_17
‘H’
MFR_MODEL_18
‘B’
MFR_MODEL_19
‘3’
MFR_MODEL_20
'B'
MFR_MODEL_21
‘C’
MFR_MODEL_22
‘-’
MFR_MODEL_23
‘A’
MFR_MODEL_24
‘B’
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 16 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code 9A HEX; (MAN_MODEL) D1U54P-W-650-12-HB3C; AC Input Variant; Back to Front Airflow (M1877)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 21
MFR_MODEL_0
9A
#Backtox9A
MFR_MODEL
D1U54P-W-650-12-HB3C
N/A
'D'
MFR_MODEL_1
'1'
MFR_MODEL_2
'U'
MFR_MODEL_3
'5'
MFR_MODEL_4
'4'
MFR_MODEL_5
'P’
MFR_MODEL_6
'-'
MFR_MODEL_7
'W'
MFR_MODEL_8
‘-‘
MFR_MODEL_10
‘6’
MFR_MODEL_11
‘5’
MFR_MODEL_12
‘0’
MFR_MODEL_13
‘-’
MFR_MODEL_14
‘1‘
MFR_MODEL_15
‘2’
MFR_MODEL_16
‘-‘
MFR_MODEL_17
‘H’
MFR_MODEL_18
‘B’
MFR_MODEL_19
‘3’
MFR_MODEL_20
'C'
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 17 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code 9B HEX; (MFR_REVISION)
Command Code (Hex)
Command Name
Value
Units
ID Length/Bit#ID/ASCII Text
MFR_MODEL_LENGTH = 14
9B
#Backtox9B
MFR_MODEL
0000-0101-0000
N/A
MFR_MODEL_0
'0'
MFR_MODEL_1
'0'
MFR_MODEL_2
‘0'
MFR_MODEL_3
‘0'
MFR_MODEL_4
'-'
MFR_MODEL_5
'0’
MFR_MODEL_6
'1'
MFR_MODEL_7
'0'
MFR_MODEL_8
‘1'
MFR_MODEL_9
‘-‘
MFR_MODEL_10
'0’
MFR_MODEL_11
'0'
MFR_MODEL_12
'0'
MFR_MODEL_13
'0’
Primary Micro
Secondary Micro
Floating Micro
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 18 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
Command Code 9C HEX (MFR_LOCATION)
Command Code (Hex)
Command Name
Value
ID Length/Bit#ID/ASCII Text
MFR_LOCATION_LENGTH = 5
9C
#Backtox9C
MFR_LOCATION
China
MFR_LOCATION_0
'C'
MFR_LOCATION_1
'h'
MFR_LOCATION_2
'i'
MFR_LOCATION_3
'n'
MFR_LOCATION_4
'a'
Command Code 9D HEX (MFR_DATE)
Command Code (Hex)
Command Name
Value
ID Length/Bit#ID/ASCII Text
MFR_DATE_LENGTH = 4
9D
#Backtox9D
MFR_DATE
1400
MFR_DATE_0
'1'
MFR_DATE_1
'4'
MFR_DATE_2
'0'
MFR_DATE_3
'0'
Command Code 9E HEX (MFR_SERIAL)
Command Code (Hex)
Command Name
Value
ID Length/Bit#ID/ASCII Text
MFR_SERIAL_LENGTH = 12
9E
#Backtox9E
MFR_SERIAL
QEyywwR1xxxx
MFR_SERIAL_0
'Q'
MFR_SERIAL_1
'E'
MFR_SERIAL_2
'y'
MFR_SERIAL_3
'y'
MFR_SERIAL_4
'w'
MFR_SERIAL_5
'w'
MFR_SERIAL_6
'R'
MFR_SERIAL_7
'1'
MFR_SERIAL_8
'x'
MFR_SERIAL_9
'x'
MFR_SERIAL_10
'x'
MFR_SERIAL_11
'x'
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 19 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
MANUFACTURERS GENERAL PARAMETRIC DATA
Command Code (Hex)
Command Name
Value
Units
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
MFR_VIN_MIN
MFR_VIN_MAX
MFR_IIN_MAX
MFR_PIN_MAX
MFR_VOUT_MIN
MFR_VOUT_MAX
MFR_IOUT_MAX
MFR_POUT_MAX
MFR_TAMBIENT_MAX
MFR_TAMBIENT_MIN
MFR_EFFICIENCY_LL_VIN
MFR_EFFICIENCY_LL_POUT1
MFR_EFFICIENCY_LL_EFF1
MFR_EFFICIENCY_LL_POUT2
MFR_EFFICIENCY_LL_EFF2
MFR_EFFICIENCY_LL_POUT3
MFR_EFFICIENCY_LL_EFF3
MFR_EFFICIENCY_HL_VIN
MFR_EFFICIENCY_HL_POUT1
MFR_EFFICIENCY_HL_EFF1
MFR_EFFICIENCY_HL_POUT2
MFR_EFFICIENCY_HL_EFF2
MFR_EFFICIENCY_HL_POUT3
MFR_EFFICIENCY_HL_EFF3
90
264
9
800
11.76
12.24
54.2
650
50
0
115
130
0.9
325
0.92
650
0.89
230
130
0.9
325
0.94
650
0.91
Vdc
Vdc
Adc
W
Vdc
Vdc
Adc
W
C
C
Vdc
W
AA
AB
W
W
Vdc
W
W
W
Scaling Coefficients
N
m
R
b
-1
-1
-6
0
-6
-6
-4
0
0
0
-1
0
-10
0
-10
0
-10
-1
0
-10
0
-10
0
-10
Read Value (Decimal)
180
528
576
800
753
783
532
650
50
0
230
130
922
325
942
650
911
460
130
922
325
963
650
932
#BacktoxA0toAB
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 20 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
OPERATION COMMAND CODE 01 HEX
Power Module On/Off Mode: Bit # / Bit Description (Command Code 01 HEX)
7
6
On/off
Bit
1
On/off
Bit
0
0
1
5
4
3
Margin on/off/high/low Bits
Valid Values
2
1
0
Bit
Bit
Power Module Status
1
0
Margin Fault
Control Bits
1
0
0
x
x
x
x
x
x
0 - 63
0 - 3F
0
x
x
x
x
x
x
128 - 191
80 - BF
Dec
Hex
Not Used
Disable power supply when OPERATION command
supported
Enable power supply when
OPERATION command supported – DEFAULT setting
#Backtox01
ON/OFF COMMAND CODE 02 HEX
Power Module On/Off Configuration: Bit # / Bit Description (Command Code 02 HEX)
7
6
5
4
3
2
Valid Values
1
0
CONTROL Pin
Dec
Hex
Power Supply On/Off Mode
reserved
reserved
reserved
CONTROL pin /
OPERATION
command PS
on/off
0
0
0
1
0
1
0
1
21
15
Control pin only ; active low polarity
0
0
0
1
0
1
1
1
23
17
Control pin only ; active high polarity
0
0
0
1
1
0
x
1
25 or 27
19 or 1B
0
0
0
1
1
1
0
1
29
1D
0
0
0
1
1
1
1
1
31
1F
Operation command only
Operation command and control pin ;
active low polarity; DEFAULT setting
Operation command and control pin ;
active high polarity
OPERATION
command on/off
On/Off
Polarity
Action
#Backtox02
EEPROM DATA; D1U54P-W-650-12-HB4C (M1876) Back to Front Airflow
Address
(HEX)
Data
Length
Register Contents (Hexadecimal Format)
Order = Low Address -> High Address
Dynamic Data Byte = "xx"
00 - 0A
11
01 00 00 00 01 00 00 FE 01 08 19
0B - 14
10
C9 4D 75 72 61 74 61 2D 50 53
15 - 1A
6
C5 4D 31 38 37 36
1B - 2F
21
30
1
31 - 3D
13
3E - 43
6
Register
Name
Static or
Dynamic
Register?
(S/D)
R/W Protected?
(Y/N)
Data
Type
Description
Header
S
N
HEX
Manufacturer
Bytes
Product Name
S
N
TEXT
Reads as "Murata-PS"
TEXT
Reads as "M1876"
D4 44 31 55 35 34 50 2D 57 2D 36 35 30 2D Part Number
31 32 2D 48 42 34 43
C0
Product
Version
Length
CC pp pp yy yy ww ww rr rr XX XX XX XX
Product Serial
Number
S
TEXT
Reads as "D1U54P-W-650-12-HB4C"
C0 C0 C0 C0 C0 C0
44
1
C1
45 - 46
2
00 00
47
1
XX
48 - FF
184
00 00 00 … 00 00 00
S
N
N
S
N
HEX
Product version, length = 0
D
N
TEXT
Custom data
S
N
HEX
CC = HEX 0xCC length identifier
pp = Product Code
yy = Serial Number Year
ww = Serial Number Week
rr = Serial Number Revision Level
XX = Serial Number
Asset tag, Custom data, FRU ID
END
S
N
HEX
Signifies end of information
UNUSED
EEPROM
S
N
HEX
Fill all unused memory locations with
0x00
Checksum
D
N
HEX
UNUSED
EEPROM
S
XX = 2's complement checksum from
0x08 - 0x46
Fill all unused memory locations with
0x00
HEX
#BacktoxE1
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 21 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
EEPROM DATA; D1U54P-W-650-12-HB3C (M1877) Front to Back Airflow
Address
(HEX)
Data
Length
Register Contents (Hexadecimal Format)
Order = Low Address -> High Address
Dynamic Data Byte = "xx"
00 - 0A
11
01 00 00 00 01 00 00 FE 01 08 19
0B - 14
10
C9 4D 75 72 61 74 61 2D 50 53
15 - 1A
6
C5 4D 31 38 37 37
1B - 2F
21
30
1
31 - 3D
13
3E - 43
6
Register
Name
Static or
Dynamic
Register?
(S/D)
R/W Protected?
(Y/N)
Data
Type
Description
Header
S
N
HEX
Manufacturer
Bytes
Product Name
S
N
TEXT
Reads as "Murata-PS"
TEXT
Reads as "M1877"
D4 44 31 55 35 34 50 2D 57 2D 36 35 30 2D Part Number
31 32 2D 48 42 33 43
C0
Product
Version
Length
CC pp pp yy yy ww ww rr rr XX XX XX XX
Product Serial
Number
S
TEXT
Reads as "D1U54P-W-650-12-HB4C"
C0 C0 C0 C0 C0 C0
44
1
C1
45 - 46
2
00 00
47
1
XX
48 - FF
184
00 00 00 … 00 00 00
S
N
N
S
N
HEX
Product version, length = 0
D
N
TEXT
CC = HEX 0xCC length identifier
pp = Product Code
yy = Serial Number Year
ww = Serial Number Week
rr = Serial Number Revision Level
XX = Serial Number
Custom data
S
N
HEX
Asset tag, Custom data, FRU ID
END
S
N
HEX
Signifies end of information
UNUSED
EEPROM
S
N
HEX
Fill all unused memory locations with
0x00
Checksum
D
N
HEX
UNUSED
EEPROM
S
XX = 2's complement checksum from
0x08 - 0x46
Fill all unused memory locations with
0x00
HEX
#BacktoxE1
PMBUS Configurable Bits
BacktoxEE
Parameter
Bit#
Data Format
Bit 0
SMBALERT
Bit 1
Bus Speed
Bit 2
PEC support
Bit 3
Bit
1
0
1
0
1
0
1
0
Function
Direct Data Format
Linear Data Format
PS does not have SMBALERT pin or does not support SMBus alert protocol
PS does have SMBALERT pin and supports SMBus alert protocol
Maximum supported bus speed = 400kHz
Maximum supported bus speed = 100kHz
Packed error checking supported
Packed error checking not supported
Default
Default
Default
Default
www.murata-ps.com/support
08 Feb 2016 ACAN59.A01 Page 22 of 23
D1U54P-W-650-12-HBxC-xxx
PMBusTM Communications Protocol
ACAN-59 Application Note
LED CONTROL; All Variants.
BacktoxEF
7
CONTROL
Bit
Bit # / Bit Description
4
3
Valid Values
6
5
Reserved
Reserved
Reserved
0
0
0
0
1
1
1
0
0
0
X
0
0
0
0
0
0
X
0
0
0
0
0
0
X
0
0
0
0
0
0
X
0
0
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
0
0
0
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
0
0
0
0
X
0
0
0
0
0
0
0
0
0
0
0
1
1
1
X
0
0
0
0
1
1
1
Reserved
2
LED Mode
Bit 2
1
0
LED Mode
LED Mode
Bit 1
Bit 0
Page 0 - INPUT LED
0
0
0
1
1
0
X
X
0
0
0
1
1
0
Page 1 - OUTPUT LED
0
0
0
1
1
0
1
1
0
0
0
1
1
0
X
X
0
0
0
1
1
0
1
1
0
0
0
1
1
0
Read / Write
LED Status & Control
Dec
Hex
0
1
2
0 - 127
128
129
130
0
1
2
0 - 7F
80
81
82
Read
Read
Read
Write
Read / Write
Read / Write
Read / Write
Auto - LED off
Auto - LED solid green
Auto - LED blinking green
Set to Auto LED control
Set to Manual - LED off
Set to Manual - LED solid green
Set to Manual - LED blinking green
0
1
2
3
4
5
6
0 - 127
128
129
130
131
132
133
134
0
1
2
3
4
5
6
0 - 7F
80
81
82
83
84
85
86
Read
Read
Read
Read
Read
Read
Read
Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Read / Write
Auto - LED off
Auto - LED solid green
Auto - LED blinking green
Auto - LED solid red
Auto - LED blinking red
Auto - LED solid yellow
Auto - LED blinking yellow
Set to Auto LED control
Set to Manual - LED off
Set to Manual - LED solid green
Set to Manual - LED blinking green
Set to Manual - LED solid red
Set to Manual - LED blinking red
Set to Manual - LED solid yellow
Set to Manual - LED blinking yellow
= Default Settings
www.murata-ps.com/support