Click Here to download this file: /data/power/okr-t3-w12.pdf

OKR-T/3 Series
www.murata-ps.com
Adjustable Output 3-Amp SIP-mount DC/DC Converters
TTypical
Ty
pical unit
FEATURES
PRODUCT OVERVIEW

600 KHz operation
The OKR-T/3 series are miniature SIP non-isolated Point-of-Load (PoL) DC/DC power converters
measuring only 0.41 x 0.65 x 0.22 inches (10.4 x 16.5 x 5.6 mm). The wide input range is 4.5 to 14 Volts
DC. Based on 600 KHz synchronous buck topology, the high power conversion efficient Point of Load (PoL)
module features programmable output voltage and On/Off control, under voltage lock out (UVLO), overcurrent and over temperature protections. These units are certified to UL/EN/ IEC 60950-1 safety standards
(2nd edition) and RoHS-6 hazardous substance compliance.

4.5-14 Vdc input voltage range

Programmable output voltage from 0.591-6.0 VDC

Drives up to 200 μF ceramic capacitive loads

High power conversion efficiency at 93%

Outstanding thermal derating performance

Over temperature and over current protection

On/Off control

SIP, 0.41 x 0.65 x 0.4 inches (10.4 x 16.5 x 10.2 mm).

Certified to UL/EN/IEC 60950-1 safety standards,
2nd edition

RoHS-6 hazardous substance compliance
Figure 1. Connection Diagram
+Vin
F1
On/Off
Control
+Vout
t4XJUDIJOH
Controller
t'JMUFST
t$VSSFOU4FOTF
External
DC
Power
Source
Trim
Open = On
Closed = Off
(Positive
On/Off)
Common
Reference and
Error Amplifier
Common
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 1 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
Performance Specifications Summary and Ordering Guide
ORDERING GUIDE
Output
Root Model
OKR-T/3-W12-C
Input
R/N (mVp-p) Regulation (Max.)
IOUT
VOUT (Amps Power
VIN Nom. Range
(Volts) max) (Watts)
Max.
Line
Load
(Volts) (Volts)
0.591-6
3
15
25
±0.3%
±1.4%
12
➀ For Vout ≥ 3.3V, Vin should be ≥ (Vout ÷ 0.85) + 0.5V.
4.5-14
Package
IIN,
IIN,
no load full load
(mA)
(Amps)
80
1.34
Efficiency
Min.
Typ.
Case
Pinout
90.75% 93%
C72
P73
wise noted. Output capacitors are 1 μF ceramic and 22 μF electrolytic in parallel. Input cap
is 22 μF. See detailed specifications. I/O caps are necessary for our test equipment and
may not be needed for your application.
➁ Ripple and Noise is shown at Vout=1V. See specs for details.
➂ All specifications are at nominal line voltage, Vout= 5V and full load, +25°C. unless other-
PART NUMBER STRUCTURE
OK R - T / 3 - W12
Okami Non-isolated PoL
E-C
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder)
SIP-Mount
Forced On/Off Control
Blank = Standard on/off, open pin = ON
E = Forced enable, open pin = OFF, see specs
Output Voltage Range
T = Trimmable, 0.591-6 Volts
Wide Input Voltage Range
W12 = 4.5 – 14 Volts
Note: Some model number combinations
may not be available. Contact Murata
Power Solutions for availability.
Maximum Rated Output
Current in Amps
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label differs from the product photograph on page 1. Here is the layout of the label:
Model Number
Product Code
OKR-T/3-W12-C
R01103
OKR-T/3-W12E-C
R01103E
The manufacturing date code is four characters:
Mfg.
date
code
XXXXXX
Product code
YMDX Rev.
Revision level
Figure 2. Label Artwork Layout
The label contains three rows of information:
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 = Jan-Sep;
O, N, D = Oct, Nov, Dec)
Third character – Day code (1 through 9 = 1 to 9, 10 = 0 and
11 through 31 = A through Z)
Fourth character – Manufacturing information
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 2 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
Performance/Functional Specifications
All specifications are typical unless noted See Note 1.
Input
Dynamic Characteristics
Input Voltage Range
See Ordering Guide.
Recommended External Fuse
6 Amps
Dynamic Load Response (50 to 100% load step, no external caps)
di/dt = 1 A/μSec
20 μSec to within ±2% of final value
Reverse Polarity Protection (Note 9)
None. Use an external fuse.
Switching Frequency
Isolation
Not isolated. The input and output
commons are internally connected.
Start-Up Voltage
4.2 Volts
Undervoltage Shutdown
3.4 Volts
Reflected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type
Environmental
Calculated MTBF (Note 4)
OKR-T/3-W12-C
OKR-T/3-W12-C
12,230,400 hours (4a)
5,273,231 hours (4b)
Capacitive
Operating Temperature Range
(Ambient temp., Vout=5 V., vertical mount)
Full power, see derating curves
-40 to +85 °C.
See Ordering Guide
Operating PC Board Range, no derating -40 to +100 °C.
Input Current:
Full Load Conditions
600 KHz
0.4 A Sec.
Storage Temperature Range
5 mA
Thermal Protection/Shutdown
+130 °C.
Output Short Circuit
60 mA
Relative Humidity
to 85%/+85 °C.
No Load, 5V out
80 mA
Restriction of Hazardous Substances
RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
Inrush Transient
Shutdown Mode (Off, UV, OT)
Low Line (Vin=Vmin, 5Vout)
Remote On/Off Control (Note 5)
Positive Logic
Current
Remote On/Off Control
Positive Logic
Current
Turn-on Time:
Vin on to Vout regulated
Remote On to Vout regulated
2
2.26 Amps
[Standard version]
ON = +2 V. to +Vin max. or open pin
OFF = –0.3 to +0.4 V. max. or ground pin
1 mA
[“E” version]
ON = +2 V. to +Vin max.,
100KΩ pulldown to ground
OFF = open pin or –0.3 to +0.4 V. max.
1 mA max.
6 mSec
6 mSec
Output
-55 to +125 °C.
Physical
Outline Dimensions
See Mechanical Specifications
Weight
0.07 ounces (2 grams)
Safety
Certified to UL/cUL 60950-1
CSA-C22.2 No. 60950-1
IEC/EN 60950-1, 2nd edtion
Absolute Maximum Ratings
Input Voltage
Continuous or transient
15 Volts max.
Output Power
15 Watts max.
On/Off Control
0 Volts. min. to +Vin. max.
Minimum Loading
No minimum load
Input Reverse Polarity Protection
See Fuse section
Output Current Range
(to rated specifications)
0 to 3 Amps
Output Current
Current-limited. Devices can withstand
sustained short circuit without damage.
Accuracy (50% load, no trim)
±2 % of Vnom
Storage Temperature
Temperature Coefficient
±0.02% per °C. of Vout range
Ripple/Noise (20 MHz bandwidth)
See Ordering Guide and note 14
Line/Load Regulation
See Ordering Guide and note 10
Efficiency
See Ordering Guide and performance
graphs
Maximum Capacitive Loading
Cap-ESR=0.001 to 0.015 Ohms
Cap-ESR >0.015 Ohms
Current Limit Inception
(98% of Vout setting, after warm up)
Short Circuit Mode (Notes 6, 12)
Short Circuit Current Output
Protection Method
removal. (Note 8)
Short Circuit Duration
(output shorted to ground)
Overvoltage protection
200 μF
1000 μF
-40 to +125 deg. C.
Absolute maximums are stress ratings. Exposure of devices to greater than any of these
conditions may adversely affect long-term reliability. Proper operation under conditions
other than those listed in the Performance/Functional Specifications Table is not implied or
recommended.
CAUTION: This product is not internally fused. To comply with safety agency certifications
and to avoid injury to personnel or equipment, the user must supply an external fast-blow
fuse to the input terminals.
8 Amps
0.6 Amp
Hiccup autorecovery upon overload
Continuous, no damage
None
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 3 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
Notes
(1) All specifications are typical unless noted. General conditions for Specifications are +25
deg.C, Vin=nominal, Vout=nominal (no trim installed), full rated load. Adequate airflow
must be supplied for extended testing under power.
All models are tested and specified with external 1μF and 22 μF paralleled output capacitors and a 22 μF external input capacitor. All capacitors are low ESR types. Caps are
layout dependent These capacitors are necessary to accommodate our test equipment
and may not be required in your applications. All models are stable and regulate within
spec under no-load conditions.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input
filtering is Cin=2 x 100 μF, 100V tantalum, Cbus=1000 μF, 100V electrolytic, Lbus=1 μH.
All caps are low ESR types.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input
voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate
brief full current outputs if the total RMS current over time does not exceed the Derating
curve. All Derating curves are presented at sea level altitude. Be aware of reduced power
dissipation with increasing altitude.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1,
Case 3, ground fixed conditions, Tpcboard=+25 ˚C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using the MIL-HDBK-217N2 method, ground
benign, +25ºC., full output load, natural convection.
(5) The On/Off Control is normally controlled by a switch or open collector or open drain transistor. But it may also be driven with external logic or by applying appropriate external
voltages which are referenced to Input Common.
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from
the selected setting.
(7) The outputs are not intended to sink appreciable reverse current.
(8) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief,
full-current output. If the overcurrent condition still exists, the restart current will be
removed and then tried again. This short current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter immediately recovers normal
operation.
(9) Input Fusing: If reverse polarity is accidentally applied to the input, to ensure reverse
input protection with full output load, always connect an external input fast-blow fuse
in series with the +Vin input. Use approximately twice the full input current rating with
nominal input voltage.
(10) Regulation specifications describe the deviation as the line input voltage or output load
current is varied from a nominal midpoint value to either extreme.
(11) CAUTION: Since the converter is mounted on the end by its pins, do not subject it to high
vibration, shock or acceleration.
(12) Output current limit and short circuit protection is non-latching. When the overcurrent
fault is removed, the converter will immediately recover.
(13) Do not exceed maximum power specifications when adjusting the output trim. All published specifications are listed at rated nominal output current using published Derating
curves. The maximum power specifications indicate brief operation before overcurrent
shutdown occurs. Note particularly that current must be limited at higher output voltage
in order to comply with maximum power requirements.
(14) At zero output current, the output may contain low frequency components which exceed
the ripple specification. The output may be operated indefinitely with no load.
(15) The input and output are not isolated. They share a single COMMON power and signal
return.
Trim Connections
Output Voltage Adustment
The output voltage may be adjusted over a limited range by connecting an
external trim resistor (Rtrim) between the Trim pin and Ground. The Rtrim
resistor must be a 1/10 Watt precision metal film type, ±0.5% accuracy or
better with low temperature coefficient, ±100 ppm/oC. or better. Mount the
resistor close to the converter with very short leads or use a surface mount
trim resistor.
In the tables below, the calculated resistance is given. Do not exceed the
specified limits of the output voltage or the converter’s maximum power
rating when applying these resistors. Also, avoid high noise at the Trim
input. However, to prevent instability, you should never connect any capacitors to Trim.
+VOUT
RTRIM
Trim
RLOAD
Ground
RTRIM (kΩ) =
1.182
VOUT − 0.591
OKR-T/3-W12
Resistor Trim Equation, OKR-T/3-W12 models:
Output Voltage
Calculated Rtrim (Ω)
6 V.
218.5
5 V.
268
3.3 V.
436
2.5 V.
619
1.8 V.
978
1.5 V.
1300
1.2 V.
1940
1.0 V.
2890
0.591 V.
∞ (open)
1.182
RTRIM (k) = _____________
(VOUT – 0.591)
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 4 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C PERFORMANCE DATA
Efficiency vs. Line Voltage and Load Current @ 25°C
Maximum Current Temperature Derating @ Sea Level
(VIN = 7V and 12V, VOUT = 5V and 6 V)
100
4.0
95
3.5
VIN = 13.8V
VIN = 12V
VIN = 7V
3.0
Output Current (Amps)
Efficiency (%)
90
85
80
Natural convection
2.5
2.0
1.5
1.0
75
0.5
70
0
0.5
1
1.5
2
2.5
3
Load Current (Amps)
3.5
0.0
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (ºC)
There is no derating for Vout = 0.591V. to 5.5V. at full load.
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 1V
On/Off Enable Startup (Vin=13.8V, Vout=1V, Iout=3A, Cload=0)
Output Ripple and Noise (Vin=12V, Vout=1V, Iout=3A, Cload=0, ScopeBW=100MHz)
Trace 4=Enable, Trace2=Vout
Step Load Transient Response (Vin=12V, Vout=1V, Cload=0, Iout=1.5A to 3A)
Step Load Transient Response (Vin=12V, Vout=1V, Cload=0, Iout=3A to 1.5A)
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 5 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 2.5V
On/Off Enable Startup (Vin=13.8V, Vout=2.5V, Iout=3A, Cload=0)
Output Ripple and Noise (Vin=12V, Vout=2.5V, Iout=3A, Cload=0, ScopeBW=100MHz)
Trace 4=Enable, Trace2=Vout
Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=1.5A to 3A)
Step Load Transient Response (Vin=12V, Vout=2.5V, Cload=0, Iout=3A to 1.5A)
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 6 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 5V
On/Off Enable Startup (Vin=13.8V, Vout=5V, Iout=3A, Cload=0)
Output Ripple and Noise (Vin=12V, Vout=5V, Iout=3A, Cload=0, ScopeBW=100MHz)
Trace 4=Enable, Trace2=Vout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=0, Iout=1.5A to 3A)
Step Load Transient Response (Vin=12V, Vout=5V, Cload=0, Iout=3A to 1.5A)
Trace 2=Vout, Trace 4=Iout, 1A/div.
Trace 2=Vout, Trace 4=Iout, 1A/div.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
For Sn/Pb based solders:
115° C.
Maximum Preheat Temperature
105° C.
Maximum Pot Temperature
270° C.
Maximum Pot Temperature
250° C.
Maximum Solder Dwell Time
7 seconds
Maximum Solder Dwell Time
6 seconds
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 7 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 1.8V
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 8 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 1.8V
Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=10x10μF X5R 0805 ceramic, plus Step Load Transient Response (Vin=4.5V, Vout=1.8V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=1.8V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 9 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 3.3V
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 10 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 3.3V
Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=10x10μF X5R 0805 ceramic, plus Step Load Transient Response (Vin=5.5V, Vout=3.3V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=3.3V, Cload=10x10μF 5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 11 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 5V
Step Load Transient Response (Vin=12V, Vout=5V, Cload=5x10μF X5R
0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=5x10μF
X5R 0805 ceramic, total 50μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=5x10μF X5R
0805 ceramic, total 50μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 12 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
OKR-T/3-W12-C OSCILLOGRAMS – Vout = 5V
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=12x10μF
X5R 0805 ceramic, total 120μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=7.5V, Vout=5V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=0A to 3A) Top trace=Vout, Bottom trace=Iout
Step Load Transient Response (Vin=12V, Vout=5V, Cload=10x10μF X5R 0805 ceramic, plus
1x470μF, 7mΩ POSCAP, total 570μF, Iout=3A to 0A) Top trace=Vout, Bottom trace=Iout
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 13 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
MECHANICAL SPECIFICATIONS
0.30
(7.62)
0.41 (10.4)
CL
0.20
(5.1)
0.205
(5.2)
0.22
(5.6)
0.05
(1.3)
REF
THK
0.12
(3.05)
0.05
(1.3)
REF
THK
0.65 (16.5)
Pin #1
0.15 (3.8)
0.15 (3.8)
Pin #5
0.067 (1.7)
0.032
(0.81)
0.032
(0.81)
0.134 (3.4)
0.05 (1.3)
0.067 (1.7)
0.134 (3.4)
0.05 (1.3)
OKR-T/6
Pin diameter: 0.032 (0.81)
Tolerance: ±0.002 (±0.05)
Pin material: Copper alloy
Pin #1
Pin finish: Pure matte tin 100-300 μin.
over 75-100 μin. nickel
OKR-T/10
OKR-T/3
Case C90
Case C72
RECOMMENDED FOOTPRINT
(VIEWED FROM TOP)
5x
0.056 MAX
ANNULAR RING
0.037±0.003
0.42
(0.017)
5x PTH
0.21
(0.008)
0.32 (0.013) MIN FOR T/6, T/10
1 2 3 4 5
0.100 (0.004)
0.24 (0.009) MIN FOR T/3
0.050 (0.002)
INPUT/OUTPUT CONNECTIONS
OKR-T-W12
Pin
1
2
3
4
5
Function P73
Remote On/Off Control
+VIN
Ground
+VOUT
Output Trim
Figure 3. OKR Series
Component locations are typical.
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
Components are shown for reference only.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 14 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
STANDARD PACKAGING
Each static dissipative polyethylene foam tray
accommodates 120 converters
2.5±.25 (63.5)
Closed height
10.00 ±.25
(254.0)
10.00±.25
(254.0)
Carton accommodates three (3) trays of 120 yielding 360 converters per carton.
0.49
(12.5)
9.92
(252.0)
6.5 X 45°
x4
0.63 (16.0)
0.39 (10.0)
0.94
(24.0)
9.92
(252.0)
0.2
(5.0)
0.33
(8.5)
0.43
(11.0)
0.2
(5.0)
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
Notes:
1. Material: Dow 220 antistat ethafoam
(Density: 34-35 kg/m3)
2. Dimensions: 252 x 252 x 16 mm
8 x 15 array (120 per tray)
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
Components are shown for reference only.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 15 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
TECHNICAL NOTES
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs of
power conversion components. Fuses should also be used when there is the
possibility of sustained input voltage reversal which is not current-limited. For
greatest safely, we recommend a fast blow fuse installed in the ungrounded
input supply line.
The installer must observe all relevant safety standards and regulations. For
safety agency approvals, install the converter in compliance with the end-user
safety standard, i.e. IEC/EN/UL 60950-1.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate properly
until the ramping-up input voltage exceeds and remains at the Start-Up
Threshold Voltage (see Specifications). Once operating, converters will not
turn off until the input voltage drops below the Under-Voltage Shutdown Limit.
Subsequent restart will not occur until the input voltage rises again above the
Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage.
Users should be aware however of input sources near the Under-Voltage
Shutdown whose voltage decays as input current is consumed (such as
capacitor inputs), the converter shuts off and then restarts as the external
capacitor recharges. Such situations could oscillate. To prevent this, make
sure the operating input voltage is well above the UV Shutdown voltage AT ALL
TIMES.
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to Vout
Start-Up Time (see Specifications) is the time interval between the point when
the ramping input voltage crosses the Start-Up Threshold and the fully loaded
regulated output voltage enters and remains within its specified accuracy band.
Actual measured times will vary with input source impedance, external input
capacitance, input voltage slew rate and final value of the input voltage as it
appears at the converter.
These converters include a soft start circuit to moderate the duty cycle of its
PWM controller at power up, thereby limiting the input inrush current.
The On/Off Remote Control interval from On command to Vout regulated
assumes that the converter already has its input voltage stabilized above the
Start-Up Threshold before the On command. The interval is measured from the
On command until the output enters and remains within its specified accuracy
band. The specification assumes that the output is fully loaded at maximum
rated current. Similar conditions apply to the On to Vout regulated specification
such as external load capacitance and soft start circuitry.
For best performance, we recommend installing a low-ESR capacitor
immediately adjacent to the converter’s input terminals. The capacitor should
be a ceramic type such as the Murata GRM32 series or a polymer type. Initial
suggested capacitor values are 10 to 22 μF, rated at twice the expected maximum input voltage. Make sure that the input terminals do not go below the
undervoltage shutdown voltage at all times. More input bulk capacitance may
be added in parallel (either electrolytic or tantalum) if needed.
Recommended Output Filtering
The converter will achieve its rated output ripple and noise with no additional
external capacitor. However, the user may install more external output capacitance to reduce the ripple even further or for improved dynamic response.
Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors.
Initial values of 10 to 47 μF may be tried, either single or multiple capacitors in
parallel. Mount these close to the converter. Measure the output ripple under
your load conditions.
Use only as much capacitance as required to achieve your ripple and noise
objectives. Excessive capacitance can make step load recovery sluggish or
possibly introduce instability. Do not exceed the maximum rated output capacitance listed in the specifications.
Input Ripple Current and Output Noise
All models in this converter series are tested and specified for input reflected
ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. In the figure below,
the Cbus and Lbus components simulate a typical DC voltage bus. Please
note that the values of Cin, Lbus and Cbus will vary according to the specific
converter model.
TO
OSCILLOSCOPE
CURRENT
PROBE
+VIN
VIN
+
–
+
–
LBUS
CBUS
CIN
-VIN
CIN = 2 x 100μF, ESR < 700mΩ @ 100kHz
CBUS = 1000μF, ESR < 100mΩ @ 100kHz
LBUS = 1μH
Figure 4. Measuring Input Ripple Current
Recommended Input Filtering
The user must assure that the input source has low AC impedance to provide
dynamic stability and that the input supply has little or no inductive content,
including long distributed wiring to a remote power supply. The converter will
operate with no additional external capacitance if these conditions are met.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 16 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
Murata Power Solutions makes Characterization measurements in a closed
cycle wind tunnel with calibrated airflow. We use both thermocouples and an
infrared camera system to observe thermal performance.
+VOUT
C1
C2
SCOPE
RLOAD
-VOUT
C1 = 1μF
C2 = 22μF
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 5. Measuring Output Ripple and Noise (PARD)
Minimum Output Loading Requirements
All models regulate within specification and are stable under no load to full
load conditions. Operation under no load might however slightly increase
output ripple and noise.
Thermal Shutdown
To prevent many over temperature problems and damage, these converters
include thermal shutdown circuitry. If environmental conditions cause the
temperature of the DC/DC’s to rise above the Operating Temperature Range
up to the shutdown temperature, an on-board electronic temperature sensor
will power down the unit. When the temperature decreases below the turn-on
threshold, the converter will automatically restart. There is a small amount of
hysteresis to prevent rapid on/off cycling. The temperature sensor is typically
located adjacent to the switching controller, approximately in the center of the
unit. See the Performance and Functional Specifications.
CAUTION: If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown.
Temperature Derating Curves
The graphs in this data sheet illustrate typical operation under a variety of
conditions. The Derating curves show the maximum continuous ambient air
temperature and decreasing maximum output current which is acceptable
under increasing forced airflow measured in Linear Feet per Minute (“LFM”).
Note that these are AVERAGE measurements. The converter will accept brief
increases in current or reduced airflow as long as the average is not exceeded.
Note that the temperatures are of the ambient airflow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that very low flow rates (below about 25 LFM) are similar to “natural
convection”, that is, not using fan-forced airflow.
CAUTION: If you routinely or accidentally exceed these Derating guidelines,
the converter may have an unplanned Over Temperature shut down. Also, these
graphs are all collected at slightly above Sea Level altitude. Be sure to reduce
the derating for higher density altitude.
Output Current Limiting
Current limiting inception is defined as the point at which full power falls below
the rated tolerance. See the Performance/Functional Specifications. Note particularly that the output current may briefly rise above its rated value in normal
operation as long as the average output power is not exceeded. This enhances
reliability and continued operation of your application. If the output current is
too high, the converter will enter the short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low (approximately 98% of nominal output voltage for most models), the magnetically
coupled voltage used to develop primary side voltages will also drop, thereby
shutting down the PWM controller. Following a time-out period, the PWM will
restart, causing the output voltage to begin ramping up to its appropriate value.
If the short-circuit condition persists, another shutdown cycle will initiate. This
rapid on/off cycling is called “hiccup mode”. The hiccup cycling reduces the
average output current, thereby preventing excessive internal temperatures
and/or component damage. A short circuit can be tolerated indefinitely.
The “hiccup” system differs from older latching short circuit systems
because you do not have to power down the converter to make it restart. The
system will automatically restore operation as soon as the short circuit condition is removed.
Remote On/Off Control (for models without the “E” option)
Please refer to the Connection Diagram on page 1 for On/Off connections.
Positive logic models are enabled when the On/Off pin is left open or is
pulled high to +Vin with respect to –Vin. Positive-logic devices are disabled
when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to –Vin.
Dynamic control of the On/Off function should be able to sink appropriate
signal current when brought low and withstand appropriate voltage when
brought high. Be aware too that there is a finite time in milliseconds (see
Specifications) between the time of On/Off Control activation and stable,
regulated output. This time will vary slightly with output load type and current
and input conditions.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 17 of 18
OKR-T/3 Series
Adjustable Output 3-Amp SIP-mount DC/DC Converters
“E” Model External Enable On/Off Control (see fig. 6)
The forced On/Off enable option for “E” models uses positive logic for the
external control. The converter may be powered ON by applying a positive voltage (logic HI) between the On/Off pin and the negative power input (-Vin). This
positive voltage is referred to –Vin and must be in the range of at least +2.0V
and not to exceed the power supply input voltage (+Vin). The current drain is 1
mA max. when turned on.
If the On/Off pin is left open, an internal 100 Kilohm pulldown resistor will
turn the converter OFF. The OFF condition may also be commanded by grounding the pin or from an external logic LO voltage not to exceed +0.4 Volts. All
voltages are referred to the –Vin negative power input.
The circuit below indicates the equivalent input. Please avoid false signals
from ground bounce errors on the On/Off control. Also note that the external
control signal is wired directly into the Q3 BSS138W gate which can be damaged by electrostatic transient voltages. Do not exceed the specifications.
Output Capacitive Load
These converters do not require external capacitance added to achieve rated
specifications. Users should only consider adding capacitance to reduce
switching noise and/or to handle spike current load steps. Install only enough
capacitance to achieve noise objectives. Excess external capacitance may
cause regulation problems, degraded transient response and possible oscillation or instability.
If you wish to control the On/Off circuit by external logic rather than a switch,
carefully compare your logic threshold voltages with that of the On/Off input.
Pos. Vin
10KΩ
On/Off Control
Min. Vgs for turn-on = 2.0V.
Max. Vgs for turn-off = 0.4V.
Neg. Vin
To
PWM
Q3
100
KΩ
BSS 138W
Figure 6. On/Off Control Circuit for “E” Models
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2016 Murata Power Solutions, Inc.
www.murata-ps.com/support
MDC_OKR-T/3-W12.B05 Page 18 of 18