SMVA1253_079LF_203205B.pdf

DATA SHEET
SMVA1253-079LF: Hyperabrupt Junction Tuning Varactor
Automotive Applications
 Low tuning voltage VCOs
 Infotainment
 Navigation
 Telematics
 Garage door openers
 Wireless control systems
Features
 AEC-Q101 qualified
 ISO/TS16949 certified facility
Description
 High capacitance ratio: C0.3V/C4.7V = 12 typical
The SMVA1253-079LF silicon hyperabrupt junction varactor diode
is designed for use in voltage controlled oscillators (VCOs) with a
low tuning voltage operation and is ideal for in-vehicle
infotainment applications. This varactor is characterized for
capacitance and resistance over temperature.
 Packages rated MSL1, 260 °C per JEDEC J-STD-020
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
Table 1 describes the SMVA1253-079LF package and marking.
Table 1. Packageand Marking
Single
SC-79
Green™
SMVA1253-079LF
Marking: Cathode and GH
LS = 0.7 nH
The Pb-free symbol or “LF” in the part number denotes a lead-free,
RoHS-compliant package unless otherwise noted as Green™.
Tin/lead (Sn/Pb) packaging is not recommended for new designs.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203205B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 7, 2015
1
DATA SHEET • SMVA1253-079LF: HYPERABRUPT JUNCTION TUNING VARACTOR
Electrical and Mechanical Specifications
The absolute maximum ratings of the SMVA1253-079LF varactor
are provided in Table 2. Electrical specifications are provided in
Table 3. Typical capacitance values are listed in Table 4. Typical
performance characteristics of the SMVA1253-079LF varactor are
illustrated in Figures 1 and 2.
The SPICE model for the SMVA1253-079LF varactor is shown in
Figure 3, and the associated model parameters are provided in
Table 5.
Table 2. SMVA1253-079LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
15
V
Reverse voltage
VR
Forward current
IF
20
mA
Power dissipation
PDIS
250
mW
Operating temperature
TOP
–55
+125
C
Storage temperature
TSTG
–55
+150
C
Electrostatic discharge:
ESD
1000
500
<50
V
V
V
Charged Device Model (CDM), Class 3
Human Body Model (HBM), Class 1A
Machine Model (MM), Class A
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SMVA1253-079LF Electrical Specifications (Note 1)
(TOP = 25 C, Unless Otherwise Noted)
CT
@ 0.3 V
(pF)
CT
@ 4.7 V
(pF)
CT
@1V
(pF)
CT
@3V
(pF)
CT @ 0.3 V
CT @ 4.7 V
(Ratio)
CT @ 1 V
CT @ 3 V
(Ratio)
RS @ 3 V,
500 MHz
(Ω)
Q @ 3 V,
50 MHz
Min.
Typical
Typical
Max.
Typical
Typical
Min.
Typical
Typical
Max.
Typical
48.0
53
4.3
4.80
37.0
7.80
11.0
12.3
4.7
1.4
350
Note 1: Performance is guaranteed only under the conditions listed in this table.
Reverse voltage VR (IR = 10 μA) = 15 V minimum
Reverse current IR (VR = 12 V) = 20 nA maximum
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
August 7, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203205B
DATA SHEET • SMVA1253-079LF: HYPERABRUPT JUNCTION TUNING VARACTOR
Table 4. Capacitance vs Reverse Voltage
VR
(V)
CT (pF)
0
69.32
0.5
50.23
1.0
37.07
1.5
27.57
2.0
19.37
2.5
12.39
3.0
7.77
3.5
5.77
4.0
4.86
4.5
4.34
5.0
4.01
5.5
3.78
6.0
3.62
6.5
3.50
7.0
3.41
7.5
3.34
8.0
3.28
Typical Performance Characteristics
+15
+2
+10
VR = 1 V
Percentage Change (%)
Percentage Change (%)
+3
+1
0
–1
–2
VR = 4 V
+5
0
–5
–10
–15
–20
–25
–3
–40
–20
0
+20
+40
+60
+80
Temperature (°C)
Figure 1. Relative Capacitance Change vs Temperature
–50
–25
0
+25
+50
+75
+100
Temperature (°C)
Figure 2. Relative Series Resistance Change vs Temperature
@ 500 MHz
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203205B • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • August 7, 2015
3
DATA SHEET • SMVA1253-079LF: HYPERABRUPT JUNCTION TUNING VARACTOR
PORT
P_anode
port = 1
IND
LS
L = LS
RES
RS
R = RS
CAP
CP
C = CP
DIODE
Varactor_Diode
AREA = 1
MODEL = Diode_Model
MODE = nonlinear
DIODEM
Diode_Model
IS = 1.00e-14
RS = 0
N=1
TT = 0
CJO = CJO
M=M
VJ = VJ
EG = 1.11
XTI = 3
KF =0
AF =1
PORT
P_Cathode
port = 2
FC = 0.5
BV = 0
IBV = 1e-3
ISR = 0
NR = 2
IKF = 0
NBV = 1
IBVL = 0
NBVL = 1
TBV1 = 0
TNOM = 27
FFE = 1
S1672
Figure 3. SPICE Model
Table 5. SPICE Model Parameters
CJO
(pF)
VJ
(V)
M
CP
(pF)
RS
(Ω)
68.30
100
71
2.00
1.1
Package and Handling Information
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SMVA1253-079LF varactor is rated to Moisture Sensitivity
Level 1 (MSL1) at 260 C. It can be used for lead or lead-free
soldering. For additional information, refer to the Skyworks
Application Note, Solder Reflow Information, document number
200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Package dimensions are shown in Figure 4, and tape and reel
dimensions are provided in Figure 5.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
August 7, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203205B
DATA SHEET • SMVA1253-079LF: HYPERABRUPT JUNCTION TUNING VARACTOR
Box
or
Bar
Polarity
Indicator Area
0.006 (0.15 mm) Min.
0.010
(0.25 mm) Min.
0.014
(0.35 mm) Max.
1
2
0.028
(0.70 mm) Min.
0.035
(0.90 mm) Max.
0.060 (1.50 mm) Min.
0.067 (1.70 mm) Max.
0.043 (1.10 mm) Min.
0.051 (1.30 mm) Max.
10° Max.
0.020
(0.50 mm) Min.
0.028
(0.70 mm) Max.
0.003
(0.07 mm) Min.
0.008
(0.20 mm) Max.
10° Max.
Dimensions are in inches (millimeters shown in parentheses)
S1652
Figure 4. SC-79 Package Dimensions
Ø1.50± 0.10
4.00 ± 0.10
4.00 ± 0.10
2.00 ± 0.05
0.229 ± 0.02 (T)
1.75 ± 0.10
B
A
B
Pin 1 Indicator
0.80 ± 0.05 (Ko)
B
8.00 ± 0.20
A
3.50 ± 0.05
1.40 ± 0.05
1.95 ± 0.05 (Bo)
2° Max
Ø0.50± 0.05
0.39 ± 0.05
2o Max
0.90 ± 0.05 (Ao)
A
Notes:
1. Carrier tape: black conductive polycarbonate or polystyrene.
2. Cover tape material: transparent conductive PSA.
3. Cover tape size: 5.4 mm width.
4. ESD-surface resistivity is ≤1 x 108 Ohms/square per
EIA, JEDEC TNR Specification.
4. All measurements are in millimeters.
S2929
Figure 5. SC-79 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203205B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 7, 2015
5
DATA SHEET • SMVA1253-079LF: HYPERABRUPT JUNCTION TUNING VARACTOR
Copyright © 2014-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
August 7, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203205B