DATA SHEET SKY13445-368LF: Dual-Band SP3T and SP2T Switch Applications WLAN 802.11 a/b/g/n/ac networks Embedded modules TX5 RX5 Features TX2 RX2 ANT5 VC1 ANT2 Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074. 11 10 1 9 VC3 VC5 2 8 BT RX5 3 7 RX2 Figure 1. SKY13445-368LF Block Diagram Description The SKY13445-368LF is a pHEMT GaAs switch. The device includes a single-pole, triple-throw (SP3T) switch for 2 GHz WLAN transmit, receive, and Bluetooth functions, and a single-pole, double-throw (SP2T) switch for 5 GHz transmit and receive functions. Both the SP3T and SP2T switches are fabricated on the same substrate. The active path is selected with five positive voltage control lines (V1, V2, and V3 for low band switching, and V4 and V5 for high band switching). In low band mode, the high band paths are in isolation by applying a low voltage to the two control lines, V4 and V5. The switch is manufactured in a compact, 2 x 2 mm, 12-pin exposed pad plastic Quad Flat No-Lead (QFN) package. 6 TX2 VC2 TX5 5 S3392 Any of the RF ports can be used for any RF function regardless of the port name. The SKY13445-368LF requires external DC blocking capacitors on all RF ports. VC4 4 VC5 VC1 VC2 Small QFN (12-pin, 2 x 2 mm) package (MSL1, 260 C per JEDEC J-STD-020) 12 ANT2 BT VC3 VC4 SP3T (2 GHz) and SP2T (5 GHz) switches with Bluetooth® capability Positive voltage control: 2.7 to 3.6 V IP0.5dB: +29.5 dBm typical @ 2.5 GHz and 3 V ANT5 S3393 Figure 2. SKY13445-368LF Pinout – 12-Pin QFN (Top View) A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202794C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 30, 2015 1 DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Table 1. SKY13445-368LF Signal Descriptions (Note 1) Pin Name Description Pin Name Description 1 VC4 Control line 4 for ANT5 to RX5 path 7 RX2 2.4 to 2.5 GHz receive port. Must be DC blocked for proper operation. 2 VC5 Control line 5 for ANT5 to TX5 path 8 BT Bluetooth RF port. Must be DC blocked for proper operation. 3 RX5 4.9 to 6.0 GHz receive port. Must be DC blocked for proper operation. 9 VC3 Control line 3 for ANT2 to RX2 path 4 TX5 4.9 to 6.0 GHz transmit port. Must be DC blocked for proper operation. 10 ANT2 2.4 to 2.5 GHz antenna port. Must be DC blocked for proper operation. 5 VC2 Control line 2 for ANT2 to TX2 path 11 VC1 Control line 1 for ANT2 to BT path 6 TX2 2.4 to 2.5 GHz transmit port. Must be DC blocked for proper operation. 12 ANT5 4.9 to 6.0 GHz antenna port. Must be DC blocked for proper operation. Note 1: Bottom ground paddle must be connected to ground. Table 2. SKY13445-368LF Absolute Maximum Ratings (Note 1) Parameter Symbol Minimum Maximum Units –0.5 +5.0 V +31 +29 dBm dBm Control voltage (room temperature, normal operating power) VCTL RF input power (OFDM modulated): 2.5 GHz, SP3T switch 5.0 GHz, SP2T switch PIN2G PIN5G Storage temperature TSTG –55 +150 C Operating temperature TOP –30 +90 C Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13445-368LF are provided in Table 2. Electrical specifications are provided in Tables 3 and 4. The state of the SKY13445-368LF is determined by the logic provided in Table 5. Typical performance characteristics of the SKY13445-368LF are illustrated in Figures 3 to 10. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 October 30, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202794C DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Table 3. SKY13445-368LF Electrical Specifications (Note 1) (VCTL = 0 V [Low] and 3 V [High], TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units 0.7 0.9 dB 2 GHz SP3T Insertion loss, 2 GHz IL ANT2 to RX2, TX2, and BT; f = 2.4 to 2.5 GHz Return loss (insertion loss state), 2 GHz RL ANT2 to RX2, TX2, and BT; f = 2.4 to 2.5 GHz 14 18 dB Isolation, 2 GHz Iso ANT2 to RX2, TX2, and BT; one path on; f = 2.4 to 2.5 GHz 18 24 dB Antenna isolation, 2 GHz Iso One 2 GHz path on, f = 2.4 to 2.5 GHz 20 22 dB One 2 GHz path on, f = 4.8 to 5.0 GHz 20 22 dB 50 ns +20 +22 dBm +27.0 +29.5 dBm Switching speed ANT2 to ANT5: 50% control to 90/10% RF steady state power Error vector magnitude EVM Input power for 2.5% error, WLAN 2.45 GHz, 802.11g, OFDM, 54 Mbps, 64 QAM 0.5 dB input compression point IP0.5dB f = 2.5 GHz Insertion loss, 5 GHz IL ANT5 to RX5 and TX5, f = 4.9 to 5.9 GHz 1.20 Return loss (insertion loss state), 5 GHz RL ANT5 to RX2 and TX2, f = 4.9 to 5.9 GHz 13 dB Isolation, 5 GHz Iso ANT5 to RX5, or ANT5 to TX5; one path on; f = 4.9 to 5.9 GHz 15.0 20.5 dB Antenna isolation, 5 GHz Iso ANT2 to ANT5, one 5 GHz path on, f = 4.8 to 5.9 GHz 15 20 dB 50 ns +17.5 +19.0 dBm +26 +28 dBm 5 GHz SP2T Switching speed 50% control to 90/10% RF steady state power Error vector magnitude EVM Input power for 2.5% error, WLAN 4.9 to 6.0 GHz, 802.11g, OFDM, 54 Mbps, 64 QAM 0.5 dB input compression point IP0.5dB f = 5.0 GHz 1.35 dB Note 1: Performance is guaranteed only under the conditions listed in this table. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202794C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 30, 2015 3 DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Table 4. SKY13445-368LF Electrical Specifications (Note 1) (VCTL = 3 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Control voltage: Low High VCTL_L VCTL_H Leakage current ILEAK Test Condition Min Typical Max Units 0 2.7 3.0 0.2 5.0 V V 15 30 μA VC1/2/3/4/5 = 3 V Note 1: Performance is guaranteed only under the conditions listed in this table. Table 5. SKY13445-368LF Truth Table (Note 1) Control Signal Logic Insertion Loss/Isolation State VC1 (Pin 11) VC2 (Pin 5) VC3 (Pin 9) VC4 (Pin 1) VC5 (Pin 2) ANT2 to BT ANT2 to TX2 ANT2 to RX2 ANT5 to Rx5 ANT5 to TX5 ANT2 to BT 1 0 0 0 0 Insertion Loss Isolation Isolation Isolation Isolation ANT2 to TX2 0 1 0 0 0 Isolation Insertion Loss Isolation Isolation Isolation ANT2 to RX2 0 0 1 0 0 Isolation Isolation Insertion Loss Isolation Isolation ANT5 to RX5 0 0 0 1 0 Isolation Isolation Isolation Insertion Loss Isolation ANT5 to TX5 0 0 0 0 1 Isolation Isolation Isolation Isolation Insertion Loss ANT2 to BT, ANT5 to RX5 1 0 0 1 0 Insertion Loss Isolation Isolation Insertion Loss Isolation ANT2 to BT, ANT5 to TX5 1 0 0 0 1 Insertion Loss Isolation Isolation Isolation Insertion Loss ANT2 to TX2, ANT5 to RX5 0 1 0 1 0 Isolation Insertion Loss Isolation Insertion Loss Isolation ANT2 to TX2, ANT5 to TX5 0 1 0 0 1 Isolation Insertion Loss Isolation Isolation Insertion Loss ANT2 to RX2, ANT5 to RX5 0 0 1 1 0 Isolation Isolation Insertion Loss Insertion Loss Isolation ANT2 to RX2, ANT5 to TX5 0 0 1 0 1 Isolation Isolation Insertion Loss Isolation Insertion Loss Function Note 1: Any state other than described in this Table places the switch into an undefined state. An undefined state will not damage the device. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 October 30, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202794C DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Typical Performance Characteristics (VCTL = 0 V [Low] and 3 V [High], TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) –10 0 –0.2 –15 –0.6 Return Loss (dB) Insertion Loss (dB) –0.4 –0.8 –1.0 –1.2 –1.4 –1.6 ANT2 to BT ANT2 to RX2 ANT2 to TX2 –1.8 –2.0 2.0 2.5 3.0 3.5 –20 –25 –30 ANT2 to RX2 ANT2 to BT ANT2 to TX2 –35 –40 2.0 4.0 2.5 3.0 3.5 4.0 4.5 5.0 Frequency (GHz) Frequency (GHz) Figure 4. Typical Input Return Loss vs Frequency (2 GHz, SP3T) Figure 3. Typical Insertion Loss vs Frequency (2 GHz, SP3T) –10 0 –0.2 –0.4 Insertion Loss (dB) Isolation (dB) –15 –20 –25 –30 ANT2 to RX2 ANT2 to TX2 ANT2 to BT ANT2 to ANT5 –35 –40 2.0 2.5 3.0 3.5 4.0 4.5 –0.6 –0.8 –1.0 –1.2 –1.4 –1.6 ANT5 to RX5 ANT5 to TX5 –1.8 –2.0 4.0 5.0 4.5 0 0 –5 –5 –10 –10 Isolation (dB) Return Loss (dB) 5.5 6.0 Figure 6. Typical Insertion Loss vs Frequency (5 GHz, SP2T) Figure 5. Typical Isolation vs Frequency (2 GHz, SP3T) –15 –20 –25 –15 –20 –25 –30 –30 ANT5 to RX5 ANT5 to TX5 –35 –40 4.0 5.0 Frequency (GHz) Frequency (GHz) –40 4.5 5.0 5.5 Frequency (GHz) Figure 7. Typical Input Return Loss vs Frequency (5 GHz, SP2T) ANT5 to RX5 ANT5 to TX5 –35 6.0 4.0 4.5 5.0 5.5 6.0 Frequency (GHz) Figure 8. Typical Isolation vs Frequency (5 GHz, SP5T) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202794C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 30, 2015 5 5.0 5.0 4.5 4.5 4.0 4.0 3.5 3.5 EVM (%) EVM (%) DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH 3.0 2.5 2.0 1.5 3.0 2.5 2.0 1.5 BT RX2 TX2 1.0 0.5 0 +10 +12 +14 +16 +18 +20 RX5 TX5 1.0 0.5 +22 0 +10 +24 +12 +14 Burst Power (dBm) +16 +18 +20 +22 Burst Power (dBm) Figure 9. Typical EVM vs Burst Power @ 2500 MHz Figure 10. Typical EVM vs Burst Power @ 5500 MHz Evaluation Board Description Package and Handling Information The SKY13445-368LF Evaluation Board is used to test the performance of the SKY13445-368LF dual-band switch. An Evaluation Board schematic diagram is provided in Figure 11. An assembly drawing for the Evaluation Board is shown in Figure 12. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. The SKY13445-368LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. Package Dimensions The PCB layout footprint for the SKY13445-368LF is provided in Figure 13. Typical part markings are shown in Figure 14. Package dimensions are shown in Figure 15, and tape and reel dimensions are provided in Figure 16. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. VC1 C8 47 pF ANT2 ANT5 10 C6 22 pF ANT2 ANT5 11 VC1 12 C5 22 pF DCH1 Header 1 VC1 C12 47 pF 3 RX5 C4 22 pF C3 22 pF TX5 VC3 VC5 BT RX5 RX2 4 5 9 C10 47 pF VC3 8 C7 22 pF 7 C1 22 pF 2 VC4 3 VC3 BT VC5 VC2 RX2 TX2 2 VC4 VC2 VC5 C11 47 pF TX5 VC4 1 4 5 6 VC1 VC4 VC3 VC5 VC2 GND C2 22 pF 6 TX2 C9 47 pF VC2 S3394 Figure 11. SKY13445-368LF Evaluation Board Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 October 30, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202794C DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH 1 2 3 4 5 6 S3395 Figure 12. SKY13445-368LF Evaluation Board Assembly Diagram 16X 0.71 Part Outline 16X 0.44 R0.20 Pin 1 Indicator 16X 0.20 0.40 Pitch 2X 0.46 2X 0.46 All measurements in millimeters Exposed Solder Area, Typical S1802 Figure 13. SKY13445-368LF PCB Layout Footprint (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202794C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 30, 2015 7 DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Pin 1 Indicator Skyworks P/N Figure 14. Typical Part Markings (Top View) Seating Plane –C– 2.00 0.92 +0.10/–0.15 –A– (0.460) 0.02 +0.03/–0.02 R0.20 Pin 1 Indicator –B– Pin 1 Indicator Detail A Pin 1 0.40 2.00 0.92 +0.10/–0.15 (0.460) 0.10 C 2X 0.55 + 0.05/–0.04 2X 0.10 C 12X 3 0.08 C 0.10 C Top View Exposed Pad 12X 0.20 Min. Side View Bottom View 0.29 ± 0.10 0.2 ± 0.05 0.10 M C A B Detail B 0.10 M C 5 All measurements are in millimeters. Dimensioning and tolerancing according to ASME Y14.5M-1994. Coplanarity applies to the terminals and all other bottom surface metalization. Plating requirement per source control drawing (SCD) 2504. Dimension applies to metalized terminal and is measured between 0.15 and 0.30 mm from terminal tip. Figure 15. SKY13445-368LF 12-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 October 30, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202794C S1731 DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH 2.00 ± 0.05 Ø1.50 + 0.10/–0.00 4.00 ± 0.10 1.75 ± 0.10 Pin 1 0.23 ± 0.05 A 2.25 ± 0.05 7º 3.50 ± 0.05 8.00 ± 0.20 0.70 ± 0.05 (Ko) Section A B 4.00 ± 0.10 A B 7º 2.25 ± 0.05 Section B Notes: 1. 2. 3. 4. 5. Carrier tape must meet all requirements of Skyworks GP01-D232 procurement spec for tape and reel shipping. Carrier tape shall be black conductive polycarbonate bakeable material at 125 ˚C temperature. Cover tape shall be transparent conductive with 5.40 mm width. ESD-surface resistivity must meet all ESD requirements of Skyworks specified on GP01-D232. All measurements are in millimeters. ts737 Figure 16. SKY13445-368LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202794C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 30, 2015 9 DATA SHEET • SKY13445-368LF: DUAL-BAND, SPDT AND SP3T WLAN SWITCH Ordering Information Model Name SKY13445-368LF Dual-Band SP2T and SP3T Switch Manufacturing Part Number SKY13445-368LF Evaluation Board Part Number SKY13445-368LF-EVB Copyright © 2013-2015 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 October 30, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202794C