201599B.pdf

DATA SHEET
SKY13410-365LF: 0.25 - 2.15 GHz 4x2 Switch Matrix with
Tone/Voltage Decoder
Applications
• DBS switching systems
• Cable TV/modems
Features
• Broadband frequency range: 0.25 to 2.15 GHz
• Tone and voltage, or mode control switching
• High isolation: 40 dB typical @ 900 MHz
• Four RF inputs, two RF outputs
• Low current consumption: 1.5 mA typical @ 5 V
• Miniature QFN (20-pin, 4 x 4 mm) package (MSL1, 260 °C per
JEDEC J-STD-020)
Figure 1. SKY13410-365LF Block Diagram
Description
The SKY13410-365LF is a four-input to two-output switch matrix
intended for Direct Broadcast Satellite (DBS) switching and cable
TV/modem applications. The SKY13410-365LF enables 16 states,
directing any of the four inputs to either of the two outputs.
Switch states are selected using tone and voltage signals together
with logic levels applied to mode control inputs. The switch can
operate over a temperature range of –40 °C to +85 °C.
The SKY13410-365LF is manufactured in a compact, 4 x 4 mm,
20-pin Quad Flat No-Lead (QFN) package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
1
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 2. SKY13410-365LF Pinout – 20-Pin QFN
(Top View)
Table 1. SKY13410-365LF Signal Descriptions
Pin #
Name
Description
Signal
Type
I/O
Pin #
Name
Description
Signal
Type
1
OUT1
RF channel output #1,
250 to 2150 MHz
RF
O
11
I3
RF input #3,
250 to 2150 MHz
RF
I
2
T1
Tone detector input #1
AC
I
12
N/C
No connection
–
–
3
V1
Voltage detector input #1
DC
I
13
V2
Voltage detector input #2
DC
I
4
N/C
No connection
–
–
14
T2
Tone detector input #2
AC
I
5
I1
RF input #1,
250 to 2150 MHz
RF
I
15
OUT2
RF channel output #2,
250 to 2150 MHz
RF
O
6
GND
Ground
GND
–
16
N/C
No connection. This pin
must be left open.
DC
–
7
I2
RF input #2,
250 to 2150 MHz
RF
I
17
B2
Mode control input #2
DC
I
8
GND
Ground
GND
–
18
B1
Mode control input #1
DC
I
9
I4
RF input #4,
250 to 2150 MHz
RF
I
19
P0
Mode control input #0
10
GND
Ground
GND
–
20
VDD
Supply voltage, +3.3 to
+5.0 V
DC
I
Technical Description
The SKY13410-365LF is controlled by a pair of DC voltage levels
applied to V1 (pin 3) and V2 (pin 13) combined with 22 kHz signal
levels applied to T1 (pin 2) and T2 (pin 14). These signals are
supplied from a set top box, receiver, etc., that is controlled by
the user.
The configuration of the switch, itself, is controlled by the logic
levels applied to P0 (pin 19), B1 (pin 18), and B2 (pin 17).
A pair of SKY13410-365LF 4x2 switches can be used to form a
4x4 switch. Figure 3 shows a suggested implementation in which
one of the 4x2 switches is mounted on the top side of a printed
circuit board, with the second 4x2 switch mounted on the back
side of the printed circuit board.
The four RF input signals, which may come from a variety of
sources but are shown here coming from four separate low-noise
block converters, are split and routed directly to the inputs of the
top-side switch and through vias to the inputs of the back-side
switch.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
I/O
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 3. Suggested Implementation of Two 4x2 Switches
With each of the configuration inputs (P0, B1, and B2) of the topside switch held at 0 V, and each of the configuration inputs of the
back-side switch held at VDD, the same logic controls from each
of the four receivers selects any specific input signal.
For example, if the user of receiver 1 wants to receive the signal
from antenna 1, polarization 1, through low-noise block A, that
receiver must send a 22 kHz tone and a control voltage greater
than the threshold voltage to switch 1. If the user of receiver 3
also wants to receive the signal from antenna 1, polarization 1,
through low-noise block A, that receiver must also send a 22 kHz
tone and a control voltage greater than the threshold voltage to
switch 2.
Other logic configurations are possible. Refer to the truth Tables
in this Data Sheet.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13410-365LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
Typical performance characteristics of the SKY13410-365LF are
illustrated in Figures 4 through 9.
The state of the SKY13410-365LF is determined by the logic
provided in Tables 4 through 13.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
3
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 2. SKY13410-365LF Absolute Maximum Ratings
Parameter
Supply voltage
Symbol
Minimum
Typical
Maximum
Units
5.5
V
5.5
V
VDD
Mode select input voltage (must not exceed
VDD)
Polarization input control voltage
RF input power
PIN
Storage temperature
TSTG
Operating temperature
TOP
Note:
21
V
+15
dBm
–65
+150
°C
–40
+85
°C
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13410-365LF Electrical Specifications (Note 1) (1 of 2)
(VDD = 0 and +3.3 to +5.0 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.25 to 0.95 GHz
0.95 to 2.15 GHz
7.5
9.0
8.0
10.0
dB
dB
0.25 to 0.95 GHz
0.95 to 2.15 GHz
0.7
2.0
1.0
3.0
dB
dB
RF Switch Specifications
Insertion loss
IL
Insertion loss flatness
Isolation
Iso
Normalized to insertion
loss
0.25 to 0.95 GHz
0.95 to 2.15 GHz
Input return loss
38
28
40
30
dB
dB
10
8
15
10
dB
dB
0.25 to 0.95 GHz
I1, I2, I3, I4
OUT1, OUT2
1 dB Input Compression Point
IP1dB
0.25 to 0.95 GHz
+12
dBm
Polarization select input current
IPT1, IPT2
VP1 and VP2 = 21 V
200
μA
Polarization select threshold voltage
VTP1, VTP2
Polarization switching time
TSPOL
Tone frequency
TF1, TF2
@ 500 mVp-p
Tone threshold voltage
TT1, TT2
@ 22 kHz with 10 nF
external DC blocking
capacitor
Tone input impedance
TZIN1, TZIN2
@ 22 kHz including
external 10 nF series
blocking capacitor
Tone/Voltage Detector Specifications
14
15
16
V
μs
0.9
7
22
800
kHz
100
170
900
mVp-p
2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
kΩ
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 3. SKY13410-365LF Electrical Specifications (Note 1) (2 of 2)
(VDD = 0 and +3.3 to +5.0, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Mode Control Specifications
0 V ≤ VCTRL ≤ VDD
Control input current
IDIG
Control input low logic level
VLOW
0
Control input high logic level
VHIGH
VDD – 1
Supply voltage
VDD
3.3
Supply current
IDD
μA
1
1
V
VDD
VDD + 0.5
V
4.2
5.0
Power Supply
1.5
V
mA
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: The SKY13410-365LF detects 22 kHz signaling amplitudes across the full specified range of the DiSEqC bus functional specification.
Anticipated Performance Characteristics
(VDD = +3.3 to +5.0, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted)
Figure 4. I1 to OUT1 and I1 to OUT2 Paths for States 0 to 15
Figure 5. I2 to OUT1 and I2 to OUT2 Paths for States 0 to 15
Figure 6. I3 to OUT1 and I3 to OUT2 Paths for States 0 to 15
Figure 7. I4 to OUT1 and I4 to OUT2 Paths for States 0 to 15
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
5
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 8. I1, I2, I3, and I4 for States 0 to 15
Figure 9. OUT1 and I2 to OUT2 Paths for States 0 to 15
Table 4. SKY13410-365LF Truth Table: Mode Control Summary (1 of 2)
Mode Paths
Mode
P0
(Pin 19)
B1
(Pin 18)
B2
(Pin 17)
I1
(Pin 5)
I2
(Pin 7)
I4
(Pin 9)
I3
(Pin 11)
0
0
0
0
A
B
C
D
1
0
0
1
A
B
D
C
2
0
1
0
B
A
C
D
3
0
1
1
B
A
D
C
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 4. SKY13410-365LF Truth Table: Mode Control Summary (2 of 2)
Mode Paths
Mode
P0
(Pin 19)
B1
(Pin 18)
B2
(Pin 17)
I1
(Pin 5)
I2
(Pin 7)
I4
(Pin 9)
I3
(Pin 11)
4
1
0
0
C
D
A
B
5
1
0
1
C
D
B
A
6
1
1
0
D
C
A
B
7
1
1
1
D
C
B
A
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
7
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 5. SKY13410-365LF Truth Table: General
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
V2
(Pin 13)
Signal Paths
1
No Tone
VLOW
No Tone
VLOW
2
No Tone
VLOW
No Tone
VHIGH
D → OUT1, B → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
D → OUT1, C → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
D → OUT1, A → OUT2
5
No Tone
VHIGH
No Tone
VLOW
B → OUT1, D → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
B → OUT1, B → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
B → OUT1, C → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
B → OUT1, A → OUT2
9
22 kHz Tone
VLOW
No Tone
VLOW
C → OUT1, D → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
C → OUT1, B → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
C → OUT1, C → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
C → OUT1, A → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
A → OUT1, D → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
A → OUT1, B → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
A → OUT1, C → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
A → OUT1, A → OUT2
D → OUT1, D → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 6. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 0 (000): P0 = B1 = B2 = 0 V (Default State)
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I3 → OUT1, I3 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I3 → OUT1, I2 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I3 → OUT1, I4 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I3 → OUT1, I1 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I2 → OUT1, I3 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I2 → OUT1, I2 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I2 → OUT1, I4 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I2 → OUT1, I1 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I4 → OUT1, I3 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I4 → OUT1, I2 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I4 → OUT1, I4 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I4 → OUT1, I1 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I1 → OUT1, I3 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I1 → OUT1, I2 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I1 → OUT1, I4 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I1 → OUT1, I1 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
9
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 7. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 1 (001): P0 = B1 = 0 V, B2 = VDD
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I4 → OUT1, I4 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I4 → OUT1, I2 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I4 → OUT1, I3 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I4 → OUT1, I1 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I2 → OUT1, I4 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I2 → OUT1, I2 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I2 → OUT1, I3 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I2 → OUT1, I1 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I3 → OUT1, I4 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I3 → OUT1, I2 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I3 → OUT1, I3 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I3 → OUT1, I1 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I1 → OUT1, I4 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I1 → OUT1, I2 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I1 → OUT1, I3 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I1 → OUT1, I1 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 8. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 2 (010): P0 = 0 V, B1 = VDD, B2 = 0 V
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I3 → OUT1, I3 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I3 → OUT1, I1 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I3 → OUT1, I4 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I3 → OUT1, I2 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I1 → OUT1, I3 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I1 → OUT1, I1 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I1 → OUT1, I4 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I1 → OUT1, I2 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I4 → OUT1, I3 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I4 → OUT1, I1 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I4 → OUT1, I4 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I4 → OUT1, I2 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I2 → OUT1, I3 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I2 → OUT1, I1 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I2 → OUT1, I4 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I2 → OUT1, I2 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
11
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 9. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 3 (011): P0 = 0 V, B1 = B2 = VDD
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I4 → OUT1, I4 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I4 → OUT1, I1 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I4 → OUT1, I3 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I4 → OUT1, I2 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I1 → OUT1, I4 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I1 → OUT1, I1 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I1 → OUT1, I3 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I1 → OUT1, I2 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I3 → OUT1, I4 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I3 → OUT1, I1 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I3 → OUT1, I3 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I3 → OUT1, I2 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I2 → OUT1, I4 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I2 → OUT1, I1 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I2 → OUT1, I3 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I2 → OUT1, I2 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 10. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 4 (100): P0 = VDD, B1 = B2 = 0 V
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I2 → OUT1, I2 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I2 → OUT1, I3 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I2 → OUT1, I1 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I2 → OUT1, I4 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I3 → OUT1, I2 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I3 → OUT1, I3 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I3 → OUT1, I1 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I3 → OUT1, I4 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I1 → OUT1, I2 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I1 → OUT1, I3 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I1 → OUT1, I1 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I1 → OUT1, I4 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I4 → OUT1, I2 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I4 → OUT1, I3 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I4 → OUT1, I1 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I4 → OUT1, I4 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
13
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 11. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 5 (101): P0 = VDD, B1 = 0 V, B2 = VDD
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I2 → OUT1, I2 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I2 → OUT1, I4 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I2 → OUT1, I1 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I2 → OUT1, I3 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I4 → OUT1, I2 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I4 → OUT1, I4 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I4 → OUT1, I1 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I4 → OUT1, I3 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I1 → OUT1, I2 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I1 → OUT1, I4 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I1 → OUT1, I1 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I1 → OUT1, I3 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I3 → OUT1, I2 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I3 → OUT1, I4 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I3 → OUT1, I1 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I3 → OUT1, I3 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
14
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 12. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 6 (110): P0 = B1 = VDD, B2 = 0 V
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I1 → OUT1, I1 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I1 → OUT1, I3 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I1 → OUT1, I2 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I1 → OUT1, I4 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I3 → OUT1, I1 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I3 → OUT1, I3 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I3 → OUT1, I2 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I3 → OUT1, I4 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I2 → OUT1, I1 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I2 → OUT1, I3 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I2 → OUT1, I2 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I2 → OUT1, I4 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I4 → OUT1, I1 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I4 → OUT1, I3 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I4 → OUT1, I2 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I4 → OUT1, I4 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
15
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Table 13. SKY13410-365LF Truth Table: Tone and Voltage Controls
Mode 7 (111): P0 = B1 = B2 = VDD
Tone and Voltage Inputs (Note 1)
State
T1
(Pin 2)
V1
(Pin 3)
T2
(Pin 14)
1
No Tone
VLOW
No Tone
VLOW
I1 → OUT1, I1 → OUT2
2
No Tone
VLOW
No Tone
VHIGH
I1 → OUT1, I4 → OUT2
3
No Tone
VLOW
22 kHz Tone
VLOW
I1 → OUT1, I2 → OUT2
4
No Tone
VLOW
22 kHz Tone
VHIGH
I1 → OUT1, I3 → OUT2
5
No Tone
VHIGH
No Tone
VLOW
I4 → OUT1, I1 → OUT2
6
No Tone
VHIGH
No Tone
VHIGH
I4 → OUT1, I4 → OUT2
7
No Tone
VHIGH
22 kHz Tone
VLOW
I4 → OUT1, I2 → OUT2
8
No Tone
VHIGH
22 kHz Tone
VHIGH
I4 → OUT1, I3 → OUT2
V2
(Pin 13)
Signal Paths
9
22 kHz Tone
VLOW
No Tone
VLOW
I2 → OUT1, I1 → OUT2
10
22 kHz Tone
VLOW
No Tone
VHIGH
I2 → OUT1, I4 → OUT2
11
22 kHz Tone
VLOW
22 kHz Tone
VLOW
I2 → OUT1, I2 → OUT2
12
22 kHz Tone
VLOW
22 kHz Tone
VHIGH
I2 → OUT1, I3 → OUT2
13
22 kHz Tone
VHIGH
No Tone
VLOW
I3 → OUT1, I1 → OUT2
14
22 kHz Tone
VHIGH
No Tone
VHIGH
I3 → OUT1, I4 → OUT2
15
22 kHz Tone
VHIGH
22 kHz Tone
VLOW
I3 → OUT1, I2 → OUT2
16
22 kHz Tone
VHIGH
22 kHz Tone
VHIGH
I3 → OUT1, I3 → OUT2
Note 1: “No Tone” = no 22 kHz tone present
“22 kHz Tone” = 22 kHz tone present with amplitude > 100 mVp-p
VLOW ≤ 14 V
VHIGH ≥ 16 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
16
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Evaluation Board Description
Package and Handling Information
The SKY13410-365LF Evaluation Board is used to test the
performance of the SKY13410-365LF 4x2 Switch Matrix. A
recommended application schematic is provided in Figure 10. An
assembly drawing for the Evaluation Board is shown in Figure 11.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The PCB layout footprint for the SKY13410-365LF is provided in
Figure 12. Typical case markings are shown in Figure 13.
Package dimensions for the 20-pin QFN are shown in Figure 14,
and tape and reel dimensions are provided in Figure 15.
THE SKY13410-365LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Figure 10. SKY13410-365LF Recommended Application Circuit
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
17
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 11. SKY13410-365LF Evaluation Board Assembly Diagram
Figure 12. SKY13410-365LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
18
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 13. Typical Case Markings
(Top View)
Figure 14. SKY13410-365LF 20-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
19
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Figure 15. SKY13410-365LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
20
January 3, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201599B
DATA SHEET • SKY13410-365LF 4X2 SWITCH MATRIX
Ordering Information
Model Name
SKY13410-365LF 4x2 Switch Matrix
Manufacturing Part Number
SKY13410-365LF
Evaluation Board Part Number
SKY13410-365LF-EVB
Copyright © 2011, 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201599B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 3, 2012
21