201693C.pdf

DATA SHEET
SKY13419-365LF: 0.25-2.15 GHz 4x2 Switch Matrix with
Tone/Voltage Detector
Applications
• DBS switching systems
• cable TV/modems
Features
• Broadband frequency range: 0.25 to 2.15 GHz
• Tone and voltage control switching
• High isolation: 40 dB @ 900 MHz
• Four RF inputs, two RF outputs
• Low current consumption: 2.5 mA @ 5 V
• Alternate truth Table logic using LGCTL pin
• Miniature QFN (20-pin, 4 x 4 mm) package (MSL1, 260 °C per
JEDEC J-STD-020)
Figure 1. SKY13419-365LF Block Diagram
Load detection and Digital Satellite Equipment Control (DiSEqC)
rejection are integrated on the switch. The SKY13419-365LF
rejects DiSEqC signals and responds only to continuous-tone and
voltage signals or vertical-horizontal mirror control inputs. The
switch on/off states are not changed by DiSEqC signals, and only
changed by continuous-tone and voltage signals or verticalhorizontal mirror control inputs.
One of the two switch outputs can be deactivated when no-tone
and no-voltage are applied to one of the tone/voltage detectors.
Description
The SKY13419-365LF is a four-input to two-output switch matrix
intended for Direct Broadcast Satellite (DBS) switching and cable
TV/modem applications. The SKY13419-365LF enables any of the
four inputs to either of the two outputs. Switch states can be
selected using tone and voltage signals together with verticalhorizontal mirror control inputs, and the logic control signal
(LGCTL, pin 9).
The SKY13419-365LF is manufactured in a compact, 4 x 4 mm,
20-pin Quad Flat No-Lead (QFN) package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
The vertical/horizontal mirror control signal (OMR, pin 18) inverts
the logic for the I2 and I4 signals (pins 16 and 20, respectively),
and for the I1 and I3 signals (pins 14 and 2, respectively). The
logic control signal inverts the logic for the I1 and I2 signals, and
for the I3 and I4 signals.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
1
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Figure 2. SKY13419-365LF Pinout – 20-Pin QFN
(Top View)
Table 1. SKY13419-365LF Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
GND
Ground
11
T1
Stereo right tone detector input
2
I3
RF input 3
12
V1
Stereo right voltage detector input
3
GND
Ground
13
GND
Ground
4
V2
Stereo left voltage detector input
14
I1
RF input 1
5
T2
Stereo left tone detector input
15
GND
Ground
6
OUT2
RF output 2
16
I2
RF input 2
7
N/C
No connection. Pin may be grounded with no
change in performance.
17
GND
Ground
8
VDD
Power supply voltage
18
OMR
Vertical/horizontal mirror (see Table 4)
9
LGCTL
Determines switch logic (see Table 4)
19
GND
Ground
10
OUT1
RF output 1
20
I4
RF input 4
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13419-365LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
Typical performance characteristics of the SKY13419-365LF are
illustrated in Figures 3 through 10.
The state of the SKY13419-365LF is determined by the logic
provided in Table 4.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Table 2. SKY13419-365LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Typical
Maximum
Units
6
V
Supply voltage
VDD
RF input power
PIN
+18
dBm
Storage temperature
TSTG
–40
+125
°C
Operating temperature
TOP
–40
+85
°C
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13419-365LF Electrical Specifications (1 of 2) (Note 1)
(VDD = 5 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
7.1
8.5
7.5
9.0
dB
dB
0.4
1.4
1.0
2.0
dB
dB
RF Specifications
Insertion loss
IL
All states
0.25 to 0.95 GHz
0.95 to 2.15 GHz
Insertion loss flatness
All states
0.25 to 0.95 GHz
0.95 to 2.15 GHz
Isolation
Iso
Normalized to insertion
loss, all states
0.25 to 0.95 GHz
0.95 to 2.15 GHz
40
36
43
38
dB
dB
Input return loss
0.25 to 2.15 GHz,
I1, I2, I3, I4, all states
12
18
dB
Output return loss
0.25 to 2.15 GHz,
OUT1, OUT2, all states
8
10
dB
1 dB Input Compression Point
IP1dB
@ 2.15 Ghz
+12
dBm
3rd Order Input Intercept Point
IIP3
@ 2.15 Ghz,
1 MHz spacing,
PIN = –12 dBm/tone
+25
dBm
Tone/Voltage Detector Specifications
Polarization select threshold voltage
Polarization switching time
With external 10 nF series
capacitor
tPOL
Polarization select voltage
= 12 to 18 V,
50% to 90% RF
14.35
15.00
15.65
1.6
V
μs
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
3
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Table 3. SKY13419-365LF Electrical Specifications (2 of 2) (Note 1)
(VDD = 5 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Tone/Voltage Detector Specifications (continued)
Tone switching time
Tone frequency
With 0.5 Vp-p,
C12 and C13 = 10 nF
(see Figure 11)
Tone threshold voltage
1.3
ms
22
kHz
100
mVp-p
Power Supply
Supply voltage
Supply current
3.3
ICC
5.0
5.5
2
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C
V
mA
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Table 4. SKY13419-365LF Truth Table
State
V1
(Pin 12)
T1
(Pin 11)
V2
(Pin 4)
T2
(Pin 5)
1
VLOW
No Tone
VLOW
2
VLOW
No Tone
3
VLOW
4
Signal Path with LGCTL Open Circuit
Signal Path with LGCTL Grounded
Pin 18 (OMR) Open
Pin 18 (OMR)
Grounded
Pin 18 (OMR) Open
Pin 18 (OMR)
Grounded
No Tone
I1 to OUT2,
I1 to OUT1
I3 to OUT2,
I3 to OUT1
I2 to OUT2,
I2 to OUT1
I4 to OUT2,
I4 to OUT1
VLOW
22 kHz Tone
I2 to OUT2,
I1 to OUT1
I4 to OUT2,
I3 to OUT1
I1 to OUT2,
I2 to OUT1
I3 to OUT2,
I4 to OUT1
No Tone
VHIGH
No Tone
I3 to OUT2,
I1 to OUT1
I1 to OUT2,
I3 to OUT1
I4 to OUT2,
I2 to OUT1
I2 to OUT2,
I4 to OUT1
VLOW
No Tone
VHIGH
22 kHz Tone
I4 to OUT2,
I1 to OUT1
I2 to OUT2,
I3 to OUT1
I3 to OUT2,
I2 to OUT1
I1 to OUT2,
I4 to OUT1
5
VLOW
22 kHz Tone
VLOW
No Tone
I1 to OUT2,
I2 to OUT1
I3 to OUT2,
I4 to OUT1
I2 to OUT2,
I1 to OUT1
I4 to OUT2,
I3 to OUT1
6
VLOW
22 kHz Tone
VLOW
22 kHz Tone
I2 to OUT2,
I2 to OUT1
I4 to OUT2,
I4 to OUT1
I1 to OUT2,
I1 to OUT1
I3 to OUT2,
I3 to OUT1
7
VLOW
22 kHz Tone
VHIGH
No Tone
I3 to OUT2,
I2 to OUT1
I1 to OUT2,
I4 to OUT1
I4 to OUT2,
I1 to OUT1
I2 to OUT2,
I3 to OUT1
8
VLOW
22 kHz Tone
VHIGH
22 kHz Tone
I4 to OUT2,
I2 to OUT1
I2 to OUT2,
I4 to OUT1
I3 to OUT2,
I1 to OUT1
I1 to OUT2,
I3 to OUT1
9
VHIGH
No Tone
VLOW
No Tone
I1 to OUT2,
I3 to OUT1
I3 to OUT2,
I1 to OUT1
I2 to OUT2,
I4 to OUT1
I4 to OUT2,
I2 to OUT1
10
VHIGH
No Tone
VLOW
22 kHz Tone
I2 to OUT2,
I3 to OUT1
I4 to OUT2,
I1 to OUT1
I1 to OUT2,
I4 to OUT1
I3 to OUT2,
2 to OUT1
11
VHIGH
No Tone
VHIGH
No Tone
I3 to OUT2,
I3 to OUT1
I1 to OUT2,
I1 to OUT1
I4 to OUT2,
I4 to OUT1
I2 to OUT2,
I2 to OUT1
12
VHIGH
No Tone
VHIGH
22 kHz Tone
I4 to OUT2,
I3 to OUT1
I2 to OUT2,
I1 to OUT1
I3 to OUT2,
I4 to OUT1
I1 to OUT2,
I2 to OUT1
13
VHIGH
22 kHz Tone
VLOW
No Tone
I1 to OUT2,
I4 to OUT1
I3 to OUT2,
I2 to OUT1
I2 to OUT2,
I3 to OUT1
I4 to OUT2,
I1 to OUT1
14
VHIGH
22 kHz Tone
VLOW
22 kHz Tone
I2 to OUT2,
I4 to OUT1
I4 to OUT2,
I2 to OUT1
I1 to OUT2,
I3 to OUT1
I3 to OUT2,
I1 to OUT1
15
VHIGH
22 kHz Tone
VHIGH
No Tone
I3 to OUT2,
I4 to OUT1
I1 to OUT2,
I2 to OUT1
I4 to OUT2,
I3 to OUT1
I2 to OUT2,
I1 to OUT1
16
VHIGH
22 kHz Tone
VHIGH
22 kHz Tone
I4 to OUT2,
I4 to OUT1
I2 to OUT2,
I2 to OUT1
I3 to OUT2,
I3 to OUT1
I1 to OUT2,
I1 to OUT1
17
No Voltage
No Tone
VLOW
No Tone
I1 to OUT2
I3 to OUT2
I2 to OUT2
I4 to OUT2
18
No Voltage
No Tone
VLOW
22 kHz Tone
I2 to OUT2
I4 to OUT2
I1 to OUT2
I3 to OUT2
19
No Voltage
No Tone
VHIGH
No Tone
I3 to OUT2
I1 to OUT2
I4 to OUT2
I2 to OUT2
20
No Voltage
No Tone
VHIGH
22 kHz Tone
I4 to OUT2
I2 to OUT2
I3 to OUT2
I1 to OUT2
21
VLOW
No Tone
No Voltage
No Tone
I1 to OUT1
I3 to OUT1
I2 to OUT1
I4 to OUT1
22
VLOW
22 kHz Tone
No Voltage
No Tone
I2 to OUT1
I4 to OUT1
I1 to OUT1
I3 to OUT1
23
VHIGH
No Tone
No Voltage
No Tone
I3 to OUT1
I1 to OUT1
I4 to OUT1
I2 to OUT1
24
VHIGH
22 kHz Tone
No Voltage
No Tone
I4 to OUT1
I2 to OUT1
I3 to OUT1
I1 to OUT1
Note:
VLOW = 10 V ~ 14.35 V
VHIGH = 15.65 V ~ 21 V
No Tone = No 22 kHz tone present
22 kHz Tone = 22 kHz tone present with amplitude greater than 100 mVp-p
No Voltage = < 5 V
Any state other than described in this Table places the switch into an undefined state. An undefined state will not damage the device.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
5
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Typical Performance Characteristics
(VDD = 5 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Figure 3. I1 to OUT1 for States 1 to 24
Figure 4. I2 to OUT1 for States 1 to 24
Figure 5. I3 to OUT1 for States 1 to 24
Figure 6. I4 to OUT1 for States 1 to 24
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Figure 7. I1 to OUT2 for States 1 to 24
Figure 8. I2 to OUT2 for States 1 to 24
Figure 9. I3 to OUT2 for States 1 to 24
Figure 10. I4 to OUT2 for States 1 to 24
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
7
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Evaluation Board Description
Package and Handling Information
The SKY13419-365LF Evaluation Board is used to test the
performance of the SKY13419-365LF 4x2 Switch Matrix. An
Evaluation Board schematic diagram is provided in Figure 11.
Component values for the SKY13419-365LF Evaluation Board are
listed in Table 5. An assembly drawing for the Evaluation Board is
shown in Figure 12.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The PCB layout footprint for the SKY13419-365LF is provided in
Figure 13. Typical case markings are shown in Figure 14.
Package dimensions for the 20-pin QFN are shown in Figure 15,
and tape and reel dimensions are provided in Figure 16.
THE SKY13419-365LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 °C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Figure 11. SKY13419-365LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Table 5. SKY13419-365LF Evaluation Board Bill of Materials
Component
Value
C1
10 μF
C2
1 μF
C3, C12, C13
10 nF
C4, C5, C14
1 nF
C6, C7, C8, C9, C10, C11
0Ω
R1, R5, R10, R12
0Ω
R2, R6
18 k Ω
R3, R4, R7, R8, R9, R11, R13
DNI
Figure 12. SKY13419-365LF Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
9
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Figure 13. SKY13419-365LF PCB Layout Footprint
(Top View)
Figure 14. Typical Case Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Figure 15. SKY13419-365LF 20-Pin QFN Package Dimensions
Figure 16. SKY13419-365LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201693C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 5, 2012
11
DATA SHEET • SKY13419-365LF 4X2 SWITCH MATRIX
Ordering Information
Model Name
SKY13419-365LF 4x2 Switch Matrix
Manufacturing Part Number
SKY13419-365LF
Evaluation Board Part Number
SKY13419-365LF-EVB
Copyright © 2011, 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
October 5, 2012 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201693C