SKY13524_639LF_202801C.pdf

DATA SHEET
SKY13524-639LF: 0.7 to 3.0 GHz High Isolation SP4T Switch
Applications
 CDMA/WCDMA/TD-SCDMA/LTE single-ended filter switching
RF1
Features
RF2
 Broadband frequency range: 0.7 to 3.0 GHz
 High isolation: 47 dB @ 2.0 GHz (typical)
RFC
RF3
 Small QFN (14-pin, 1.6 x 1.6 mm) package
(MSL1, 260 C per JEDEC J-STD-020)
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
V2
V1
VDD
Logic and Supply
Y2307
RF4
Figure 1. SKY13524-639LF Block Diagram
Description
The SKY13524-639LF is a single-pole, four-throw (SP4T) switch
used for single-ended filter switching in cellular applications. The
SKY13524-639LF maintains low insertion loss and high isolation
for all switching paths.
Depending on the logic voltage level applied to the control pins
(V1 and V2), the RFC pin is connected to one of four switched RF
outputs (RF1 to RF4) using a low insertion loss path, while the
paths between the RFC pin and the other RF pins are in a high
isolation state.
The SKY13524-639LF is manufactured in a compact, 14-pin
1.6 x 1.6 mm, Quad Flat No-Lead (QFN) package. A functional
block diagram is shown in Figure 1. The pin configuration and
package are shown in Figure 2. Signal pin assignments and
functional pin descriptions are provided in Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202801C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2015
1
RF1
GND
RF2
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
14
13
12
GND
RFC
2
10
V1
VDD
3
9
V2
GND
4
8
N/C
5
6
7
RF3
11
GND
1
RF4
GND
S3403
Figure 2. SKY13524-639LF Pinout – 14-Pin QFN
(Top View)
Table 1. SKY13524-639LF Signal Descriptions (Note 1)
Pin
Name
Description
Pin
Name
Description
1
GND
Ground
8
N/C
Not connected
2
RFC
Antenna port. No DC blocking capacitor required.
9
V2
Control voltage 2
3
VDD
DC power supply
10
V1
Control voltage 1
4
GND
Ground
11
GND
Ground
5
RF4
RF input/output port 4. DC blocking capacitor required.
12
RF2
RF input/output port 2. DC blocking capacitor required.
6
GND
Ground
13
GND
Ground
7
RF3
RF input/output port 3. DC blocking capacitor required.
14
RF1
RF input/output port 1. DC blocking capacitor required.
Note 1: Bottom ground paddles must be connected to ground.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
September 2, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202801C
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
Functional Description
Electrical and Mechanical Specifications
The SKY13524-639LF includes an internal decoder and internal
blocking capacitors on the RF common ports. External DC
blocking capacitors are required on the RF1, RF2, RF3, and RF4
ports for proper operation. DC decoupling capacitors may be
added on the VDD and control lines if necessary.
The absolute maximum ratings of the SKY13524-639LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
The state of the SKY13524-639LF is determined by the logic
shown in Table 4.
Switching is controlled by two control voltage inputs, V1 and V2.
Depending on the logic voltage level applied to the control pins,
the antenna pin is connected to one of four switched RF outputs.
Table 2. SKY13524-639LF Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Supply voltage
VDD
Control voltage (V1, V2)
VCTL
RF input power
PIN
Operating temperature
TOP
–30
Storage temperature
TSTG
–55
–0.5
Maximum
Units
3.7
V
+3.3
V
+26
dBm
+90
C
+150
C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202801C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2015
3
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
Table 3. SKY13524-639LF General Electrical Specifications (Note 1)
(VDD = 3.3 V, V1 = V2 = High = 1.8 V, PIN = 0 dBm, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Test Condition
(Note 2)
Symbol
Min
Typical
Max
Units
3.3
V
5
10
μA
1.80
3.30
0.45
V
V
5
μA
0.9
1.0
1.05
dB
dB
dB
DC Specifications
Supply voltage
VDD
2.5
Supply current
IDD
Control voltage:
High
Low
VCTL_H
VCTL_L
Control current
ICTL
V1 = V2 = 1.8 V,
VDD = 3.3 V
Insertion loss (RFC pin to RF1/2/3/4 pins)
IL
704 to 960 MHz
1710 to 2170 MHz
2300 to 2690 MHz
Isolation (RFC pin to RF1/2/3/4 pins)
Iso
704 to 960 MHz
1710 to 2170 MHz
2300 to 2690 MHz
Voltage standing wave ratio, all ports
VSWR
0.7 to 3.0 GHz, referenced
to 50 Ω
VDD = 3.3 V
1.35
0
RF Specifications
0.1 dB input compression point (RFC pin to
RF1/2/3/4 pins)
IP0.1dB
Third order input intercept point
IIP3
0.7
0.8
0.85
50
49
48
dB
dB
dB
1.4
–
+32
dBm
0.7 to 3.0 GHz, all RF
ports, fo = 0.8 to 3.0 GHz,
Δf = 1 MHz,
PIN = +20 dBm/tone
+56
dBm
Measured from 50% of
final VDD supply voltage
to final RF power ±1 dB
400
550
ηs
Measured from 50% of
final VCTRL voltage to
final RF power ±1 dB
500
650
ηs
47
46
45
0.7 to 3.0 GHz
Turn-on/turn-off time
Switching speed
Table 4. SKY13524-639LF Control Logic
Note:
VDD
(Pin 3)
V1
(Pin 10)
V2
(Pin 9)
Insertion Loss Path
1
1
0
RFC to RF1
1
0
0
RFC to RF2
1
0
1
RFC to RF3
1
1
1
RFC to RF4
“1” = 1.8 V; “0” = 0 V. Any state other than that described in this Table places the switch into an undefined state. An undefined state will not damage the device.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
September 2, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202801C
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
Evaluation Board Description
Package and Handling Information
The SKY13524-639LF Evaluation Board is used to test the
performance of the SKY13524-639LF SP4T Switch. An Evaluation
Board schematic diagram is provided in Figure 3. An assembly
drawing for the Evaluation Board is shown in Figure 4.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SKY13524-639LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Package Dimensions
The PCB layout footprint for the SKY13524-639LF is provided in
Figure 5. Typical case markings are shown in Figure 6. Package
dimensions for the 14-pin QFN are shown in Figure 7, and tape
and reel dimensions are provided in Figure 8.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
RF1
GND
C4
47 pF
14
RF1
1
13
GND
RF2
12
C5
47 pF
RF2
GND
GND
11
GND
GND
2
RFC
3
C1
10 nF
RFC
V1
VDD
V2
10
DCH1 Header
4
GND
3
V1
2 V2
9
1 VDD
4
GND
RF4
C2
47 pF
GND
N/C
RF4
GND
RF3
5
6
7
8
RF3
C3
47 pF
GND
ts185
Figure 3. SKY13524-639LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202801C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2015
5
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
RFC
RF4
RF1
RF3
RF2
C1 = 10 nF
C2, C3, C4, C5 = 47 pF
VDD V2 V1 GND
ts186
Figure 4. SKY13524-639LF Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
September 2, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202801C
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
14X 0.200
Pin 14
Pin 1 Indicator
0.22 × 0.22
4X 0.180 × 0.075
4X 0.152 × 0.064
Exposed Soldering
Area
Pin 1
0.400 Pitch
3X 1.944
2X 0.370
14X 0.200
4X 0.345
10X 0.400
2X 0.370
4X 1.944
Y2308
All dimensions are in millimeters.
Figure 5. SKY13524-639LF PCB Layout Footprint
(Top View)
Pin 1
Indicator
Part number
SKY
3524
ts188
Figure 6. Typical Part Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202801C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2015
7
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
Seating
Plane
C
1.60
A
0.40 Pitch
Exposed Pad
See Detail A
B
Pin 1
Indicator
0.02 +0.03
–0.02
12
See Detail B
1.60
14
11
R0.22
Pin 1 Indicator
1
0.74 +0.1
–0.15
20°
8
0.05 C
2X
2X
0.45 +0.05
–0.04
0.10 C
0.05 C
Top View
4
7
See Detail C
14X 0.200 Min
14X
3
0.08 C
0.10
0.20
5
0.74 +0.1
–0.15
Side View
Bottom View
0.163 ± 0.05
0.150 Typ
R0.05 Typ.
0.150 Typ
0.18 ± 0.05
0.2 ± 0.05
R0.05 Typ
0.18 ± 0.05
0.150 Typ
0.2 ± 0.05
R0.05 Typ
5
0.18 ± 0.05
0.10 M C A B
0.05 M C
Detail A
Scale: 100X
1X This Rotation
1X Rotated 180°
0.2 ± 0.05
R0.05 Typ
Detail B
Scale: 100X
1X This Rotation
1X Rotated 180°
1X Mirrored
1X Mirrored 180°
Notes:
1.
2.
3.
4.
5.
All measurements are in millimeters.
Dimensions and tolerances according to ASME Y14.5M-1994.
Coplanarity applies to the terminals and all other bottom surface metallization.
Plating requirement per source control drawing (SCD) 2504.
Dimension applies to metallized terminal. If the terminal has a radius on its end,
the width dimension should not be measured in that radius area.
5
0.10 M C A B
0.18 ± 0.05
0.05 M C
Detail C
Scale: 100X
1X This Rotation
1X Rotated 180°
1X Rotated 90° CW
1X Rotated 90° CCW
Figure 7. SKY13524-639LF 14-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
September 2, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202801C
S3402
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
ϕ1.50± 0.10
4.00 ± 0.10
2.00 ± 0.05
0.20 ± 0.02 (T)
1.75 ± 0.10
Pin 1
1.78 ± 0.05 (Bo)
B
A
A
8.00 +0.30/–0.10
3.50 ± 0.05
5o Max
B
0.69 ± 0.05 (Ko)
ϕ0.50± 0.05
B
5o Max
1.78 ± 0.05 (Ao)
A
Notes:
1. Carrier tape: black conductive polycarbonate.
2. Cover tape material: transparent conductive PSA.
3. Cover tape size: 5.4 mm width.
4. All measurements are in millimeters.
5. ESD surface resistivity is ≤1 x 108 Ohms/square per EIA, JEDEC
tape and reel specification.
6. Pin 1 orientation is in lower left corner for SOT-666 packages.
Pin 1 orientation is in upper left corner for 1.5 x 1.5 mm
and 1.6 x 1.6 mm MLPD, QFN, and DFN packages.
S1382
Figure 8. SKY13524-639LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202801C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 2, 2015
9
DATA SHEET • SKY13524-639LF: HIGH ISOLATION SP4T SWITCH
Ordering Information
Model Name
SKY13524-639LF: 0.7 to 3.0 GHz High Isolation SP4T Switch
Manufacturing Part Number
SKY13524-639LF
Evaluation Board Part Number
SKY13524-639LF-EVB
Copyright © 2013-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
September 2, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202801C