DATA SHEET VDD Applications 2G GSM/EDGE 3G WCDMA SPI_DATA SPI_CLK SPI_FRM SPI_VDD SKY18106-455LF: 0.4 to 2.2 GHz SP8T Antenna Switch with GSM Transmit Filters SPI Controller Features Wideband frequency range: 0.4 to 2.2 GHz Supports quad-band GSM/EDGE with up to six bands of WCDMA or LTE Low insertion loss: 0.75 dB @ GSM, 1 GHz (includes transmit filter loss) 0.90 dB @ GSM, 2 GHz (includes transmit filter loss) 0.50 dB @ WCDMA transmit, 1 GHz 0.75 dB @ WCDMA transmit, 2.1 GHz Good 2nd and 3rd harmonic performance: –45/–45 dBm @ +35 dBm and +33 dBm for low band and high band, respectively Over 20 dB GSM/EDGE harmonic attenuations Battery supply voltage: 2.65 to 6.00 V SPI logic (VHIGH = 1.8 V) Small, QFN (26-pin, 3.0 x 3.8 mm) package (MSL1, 260 C per JEDEC J-STD-020) Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04–0074. TRX6 TRX5 TRX4 2G_LB_TX SP8T 2G_HB_TX TRX3 TRX2 TRX1 S1736 Figure 1. SKY18106-455LF Block Diagram Description The SKY18106-455LF is a single-pole, eight-throw (SP8T) front-end module (FEM) switch designed for multi-mode, high-power switching applications that demand low harmonics and low insertion loss. The switch is optimized for both 2G GSM/EDGE and 3G WCDMA applications. No external blocking capacitors are required on the RF ports. The SKY18106-455LF consists of an SP8T switch, GSM transmit signal harmonic filters, and a serial peripheral interface (SPI) controller. The low current consumption of the device makes it very suitable for battery-operated applications. The switch is provided in a compact 3.0 x 3.8 mm Quad Flat NoLead (QFN) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201162P • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 16, 2015 1 VDD SPI_VDD SPI_FRM SPI_CLK SPI_DATA DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH 26 25 24 23 22 2 20 TRX1 GND 3 19 GND TRX5 4 18 TRX2 GND 5 17 GND TRX4 6 16 TRX3 GND 7 15 GND GND 8 14 ANT 9 10 11 12 13 GND TRX6 2G_HB_TX GND GND 21 GND 1 2G_LB_TX GND S1738 Figure 2. SKY18106-455LF Pinout – 26-Pin QFN (Top View) Table 1. SKY18106-455LF Signal Descriptions (1 of 2) Pin Name Description Pin Name Description 1 GND Ground 10 GND Ground 2 TRX6 3G WCDMA transmit arm 6. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 11 GND Ground 3 GND Ground 12 2G_HB_TX High band GSM transmit. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 4 TRX5 3G WCDMA transmit arm 5. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 13 GND Ground 5 GND Ground 14 ANT Antenna port. This pin is either connected directly to or is disconnected from pins 2, 4, 6, 9, 12, 16, 18, or 20, depending on the control data applied to pin 22. 6 TRX4 3G WCDMA transmit arm 4. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 15 GND Ground 7 GND Ground 16 TRX3 3G WCDMA transmit arm 3. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 8 GND Ground 17 GND Ground 9 2G_LB_TX Low band GSM transmit. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 18 TRX2 3G WCDMA transmit arm 2. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Table 1. SKY18106-455LF Signal Descriptions (2 of 2) Pin Name Description Pin Name Description 19 GND Ground 23 SPI_CLK SPI clock signal. 20 TRX1 3G WCDMA transmit arm 1. This pin is either connected directly to or is disconnected from pin 14, depending on the control data applied to pin 22. 24 SPI_FRM SPI enable signal (slave select). 21 GND Ground 25 SPI_VDD SPI power supply for all slave devices (1.8 V nominal). 22 SPI_DATA SPI data signal for read/write access. 26 VDD Battery supply voltage input. Electrical and Mechanical Specifications controlled as described in Table 6. The switch may also be used in one of three modes: active, standby, and isolation. These modes are controlled by bits [15:11] of the SPI data word. The absolute maximum ratings of the SKY18106-455LF are provided in Table 2. Electrical specifications are provided in Table 3. NOTE: The SPI_VDD signal (pin 25) must be pushed high for 2 ms before the first SPI command is sent to program the switch within the operating temperature range (TOP). Table 4 provides the format of the 30-bit SPI_DATA signal. Table 5 describes the values assigned to the contents of the SPI_DATA signal. The SKY18106-455LF can operate in one of 16 states as listed in Table 6. When VDD is high, the switch is active and its state is Table 2. SKY18106-455LF Absolute Maximum Ratings (Note 1) Maximum Units Supply voltage Parameter VDD Symbol Minimum Typical 7 V Input power PIN +36 dBm Storage temperature TSTG –50 +100 C Operating temperature TOP –30 +85 C Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P 3 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Table 3. SKY18106-455LF Electrical Specifications (Note 1) (1 of 2) (VDD = 2.75 V, TOP = +25 C, SPI_VDD = 1.8 V, All Ports Terminated With a 50 Ω Load, Unless Otherwise Noted) Parameter Symbol Typical Max Units 2G_TX_LB, 824 to 915 MHz 0.75 0.85 dB 2G_TX_HB, 1710 to 1910 MHz 0.90 1.00 dB 2G_TX_LB, 824 to 915 MHz 0.85 0.95 dB 2G_TX_HB, 1710 to 1910 MHz 1.00 1.10 dB 1920 to 2170 MHz 0.75 0.85 dB 1920 to 2170 MHz 0.85 0.95 dB 1710 to 1990 MHz 0.7 0.8 dB 1710 to 1990 MHz 0.8 0.9 dB Insertion loss, TRX arms (Bands 5 and 8) 824 to 960 MHz 0.50 0.65 dB Insertion loss, TRX arms (Bands 5 and 8) TOP = +85 °C 0.60 0.75 dB Insertion loss, 2G Insertion loss, 2G Test Condition Min TOP = +85 °C Insertion loss, TRX arms (Band 1) Insertion loss, TRX arms (Band 1) TOP = +85 °C Insertion loss, TRX arms (Bands 2 and 3) Insertion loss, TRX arms (Bands 2 and 3) TOP = +85 °C 824 to 960 MHz Isolation 2G_TX_LB to ANT, 824 to 915 MHz 2G_TX_HB to ANT, 1710 to 1910 MHz 2G_TX_HB/2G_TX_LB to any TRX port 25 28 dB 30 35 dB 25 30 dB Isolation, ANT to all “off” TRX ports @ 2170 MHz 20 25 dB Isolation, TRX to all “off” TRX ports @ 2170 MHz 20 23 dB Return loss ANT port 15 20 dB Harmonics 2fo and 3fo Third order intermodulation distortion, all TRX ports to ANT port IMD3 2G_TX_LB to ANT, +35 dBm 2G_TX_LB to ANT, +35 dBm, ANT VSWR = 4:1 –46 –42 dBm –36 –33 dBm 2G_TX_HB to ANT, +33 dBm 2G_TX_HB to ANT, +33 dBm, ANT VSWR = 4:1 –46 –42 dBm –36 –33 dBm 3G TRX ports to ANT, +26 dBm 3G TRX ports to ANT, +26 dBm, ANT VSWR = 4:1 –55 –50 dBm –50 –45 dBm –102 –97 dBm All blockers, all phase angles, transmit power = +15 dBm, blocker power = –20 dBm Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Table 3. SKY18106-455LF Electrical Specifications (Note 1) (2 of 2) (VDD = 2.75 V, TOP = +25 C, SPI_VDD = 1.8 V, All Ports Terminated With a 50 Ω Load, Unless Otherwise Noted) Parameter Symbol Harmonics attenuation (low band) Test Condition 2fo 2 harmonics attenuation, 2G_TX_LB to ANT 3rd harmonics attenuation, 2G_TX_LB to ANT 4th harmonics attenuation, 2G_TX_LB to ANT 3fo 4fo Harmonics attenuation (high band) 2 harmonics attenuation, 2G_TX_HB to ANT 3rd harmonics attentuation, 2G_TX_HB to ANT 4th harmonics attenuation, 2G_TX_HB to ANT 3fo 4fo Switching speed VDD Supply current: active mode standby mode IDD Typical Units 22 dB 24 dB 16 dB 24 dB 22 dB 16 dB Path to path 2 μs Standby to any “on” path 6 μs 2.75 6.00 V 500 3 800 μA μA 2.65 Control voltage SPI VDD high 1.6 1.8 2.0 V SPI VDD low –0.3 0 +0.3 V SPI VDD x 70% 1.8 SPI VDD + 0.3 V 0 SPI VDD x 30% V SPI control input voltage high SPI control input voltage low Voltage standing wave ratio, all ports Max nd 2fo Supply voltage Min nd VSWR 1:2 Inband ripple, all ports 1:5 – 0.2 dB Note 1: Performance is guaranteed only under the conditions listed in this table. Table 4. Data Bit Format (SPI_DATA Signal) 29 28 A13 A12 R/W 27 26 25 24 A11 A10 A9 A8 Address (Slave Type) 23 22 21 20 19 A7 A6 A5 A4 A3 Address (Slave Identifier) 18 17 16 A2 A1 A0 Address (Slave SPI Register) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Data Bits Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P 5 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Table 5. Data Bit Descriptions (SPI_DATA Signal) Bit Bit ID Function Value (Binary) Description 29 A13 Read/write mode 0 or 1 “1” = read, “0” = write 28 A12 27 A11 26 A10 1 25 A9 0 24 A8 0 23 A7 22 A6 1 21 A5 0 20 A4 0 19 A3 0 18 A2 17 A1 0 16 A0 0 0 Address (Slave Type) Address (Slave Identifier) Address (Slave SPI Register) 0 0 0 15 D15 Active mode on or off 1 or 0 14 D14 Data bit select 4 (MSB) – 13 D13 Data bit select 3 – 12 D12 Data bit select 2 – 11 D11 Data bit select 1 (LSB) – 10 D10 – 9 D9 – 8 D8 – 7 D7 – 6 D6 – 5 D5 4 D4 – 3 D3 – 2 D2 – 1 D1 – 0 D0 – Not used – 001 used for the SKY18106-455LF Non-volatile value programmed by vendor Not used See Table 6 Reserved Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Table 6. SKY18106-455LF Truth Table (SPI_DATA, Bits [15:11]) Active Mode Bias State Bit[15] Bit[14] Bit[13] Bit[12] Bit[11] Switch disabled (low current mode/standby mode) 0 0 0 0 0 2 GSM high band 1 0 0 0 1 3 GSM low band 1 0 0 1 0 4 Reserved 1 0 0 1 1 5 TRX1 1 0 1 0 0 6 TRX2 1 0 1 0 1 7 TRX3 1 0 1 1 0 8 Reserved 1 0 1 1 1 9 TRX4 1 1 0 0 0 10 TRX5 1 1 0 0 1 11 TRX6 1 1 0 1 0 12 Reserved 1 1 0 1 1 13 Reserved 1 1 1 0 0 14 Reserved 1 1 1 0 1 15 Reserved 1 1 1 1 0 16 Isolation state 1 1 1 1 1 1 Band SPI Data Word Evaluation Board Package and Handling Information The SKY18106-455LF Evaluation Board is used to test the performance of the SKY18106-455LF Antenna Switch. An Evaluation Board schematic diagram is provided in Figure 3. An assembly drawing for the Evaluation Board is shown in Figure 4. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Package Dimensions The SKY18106-455LF is rated to Moisture Sensitivity Level 1 (MSL1) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, Solder Reflow Information, document number 200164. The PCB layout footprint for the SKY18106-455LF is provided in Figure 5. Typical part markings are shown in Figure 6. Package dimensions for the 26-pin QFN are shown in Figure 7, and tape and reel dimensions are provided in Figure 8. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P 7 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH SPI Enable Signal SPI Power Supply SPI Clock Signal C1 10 nF SPI Data Signal 6 Transmit/Receive RF Port 4 7 8 Transmit/Receive RF Port 1 SPI_DATA 19 GND GND TRX5 TRX2 18 Transmit/Receive RF Port 2 17 GND GND TRX4 TRX3 16 Transmit/Receive RF Port 3 15 GND GND GND 9 10 11 12 C3 4.5 pF 14 ANT GND 5 21 GND 20 2G_HB_TX 4 Transmit/Receive RF Port 5 22 TRX1 GND 3 23 TRX6 GND 2 Transmit/Receive RF Port 6 GND 2G_LB_TX 1 24 SPI_CLK 25 VDD 26 SPI_FRM C2 10 nF SPI_VDD Battery Supply Voltage Antenna L1 18 nH L2 18 nH 13 GSM RF Port, Low Band GSM RF Port, High Band Notes: Components L1, L2, and C3 are recommended for ESD protection. No DC blocking capacitors are needed on the RF ports. S1978 Figure 3. SKY18106-455LF Evaluation Board Schematic C4 C3 C2 C1 D SPI_VD VDD M SPI_ CLK SPI_ DAT A C5 SPI_FR TRX6 TRX1 TRX5 TRX2 TRX4 TRX3 ANT 2G_LB_TX 2G_HB_TX S1973 Figure 4. SKY18106-455LF Evaluation Board Assembly Drawing Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Pin 26 2X 0.928 16X 1.23 R0.2 26X 0.42 Pin 1 26X 0.2 0.4 Pitch 0.2 2X 1.328 Stencil aperture size for center ground pad should be 80% to 100% (by area) of the solder mask opening 10X 1.63 Package Outline Stencil Aperture Top View 7X 1.23 16X 1.18 Pin 26 14X 0.42 Pin 26 Pin 1 26X 0.52 Pin 1 26X 0.3 0.25 Typ 14X 0.2 0.4 Pitch 0.2 0.4 Pitch 7X 1.63 Thermal Via Array will improve thermal performance. 0.2 2X 1.328 Package Outline Metallization Top View 16X 1.58 2X 0.928 Package Outline Solder Mask Opening Top View All measurements are in millimeters S1984 Figure 5. SKY18106-455LF PCB Layout Footprint (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P 9 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Skyworks Part # Lot # Date Code: (YY = Calendar Year WW = Week CC = Country Code) Pin 1 Indicator Figure 6. Typical Case Markings (Top View) Seating Plane 3.00 A Pin 1 Indicator 1.855 +0.10/–0.15 C B 26X 0.25 Min. 0.02 + 0.03/–0.02 R0.2 2.655 +0.10/–0.15 Detail A 3.80 0.10 C 2X 0.75 ± 0.05 26X 2X 0.10 C 0.10 C Top View 3 0.08 C Side View 0.40 Pitch Bottom View 0.27 ± 0.1 0.2 ± 0.05 0.10 M C A B Detail A Scale: 80X 26 Places 5 All measurements are in millimeters. Dimensioning and tolerancing according to ASME Y14.5M-1994. Coplanarity applies to the terminals and all other bottom surface metalization. Dimension applies to metalized terminal and is measured between 0.15 mm and 0.30 mm from terminal tip. Figure 7. SKY18106-455LF 26-Pin QFN Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P S2413 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH 0.30 ± 0.05 2.00 ± 0.05 4.00 ± 0.10 B ∅1.50 +0.10 –0.00 1.75 ± 0.10 1.10 ± 0.10 A B 8.00 ± 0.10 12.00 ± 0.30 A 5.50 ± 0.05 4.10 ± 0.10 (Bo) Pin 1 Indicator ∅1.50 Min Section B 3.30 ± 0.10 (Ao) Direction of Feed Section A Notes: 1. Carrier tape must meet all requirements of Skyworks GP01-D233 procurement spec for tape and reel shipping. 2. Carrier tape: black conductive polycarbonate or polystyrene. 3. Cover tape: transparent conductive material. 4. ESD-surface resistivity is ≤1 x 1010 Ohms/square per EIA, JEDEC TNR Specification. 5. Ten-sprocket hole pitch cumulative tolerance: ±0.20 mm. 6. Ao and Bo measured on plane 0.30 mm above the bottom of the pocket. 7. All measurements are in millimeters. Y2093 Figure 8. SKY18106-455LF Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P 11 DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH Ordering Information Model Name SKY18106-455LF: SP8T Antenna Switch Manufacturing Part Number SKY18106-455LF Evaluation Board Part Number EN31-D655-001_V1 Copyright © 2010- 2013, 2015 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 12 June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P