SKY18106_455LF_201162P.pdf

DATA SHEET
VDD
Applications
 2G GSM/EDGE
 3G WCDMA
SPI_DATA
SPI_CLK
SPI_FRM
SPI_VDD
SKY18106-455LF: 0.4 to 2.2 GHz SP8T Antenna Switch with
GSM Transmit Filters
SPI Controller
Features
 Wideband frequency range: 0.4 to 2.2 GHz
 Supports quad-band GSM/EDGE with up to six bands of WCDMA
or LTE
 Low insertion loss:
 0.75 dB @ GSM, 1 GHz (includes transmit filter loss)
 0.90 dB @ GSM, 2 GHz (includes transmit filter loss)
 0.50 dB @ WCDMA transmit, 1 GHz
 0.75 dB @ WCDMA transmit, 2.1 GHz
 Good 2nd and 3rd harmonic performance: –45/–45 dBm
@ +35 dBm and +33 dBm for low band and high band,
respectively
 Over 20 dB GSM/EDGE harmonic attenuations
 Battery supply voltage: 2.65 to 6.00 V
 SPI logic (VHIGH = 1.8 V)
 Small, QFN (26-pin, 3.0 x 3.8 mm) package
(MSL1, 260 C per JEDEC J-STD-020)
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
TRX6
TRX5
TRX4
2G_LB_TX
SP8T
2G_HB_TX
TRX3
TRX2
TRX1
S1736
Figure 1. SKY18106-455LF Block Diagram
Description
The SKY18106-455LF is a single-pole, eight-throw (SP8T)
front-end module (FEM) switch designed for multi-mode,
high-power switching applications that demand low harmonics
and low insertion loss. The switch is optimized for both
2G GSM/EDGE and 3G WCDMA applications. No external blocking
capacitors are required on the RF ports.
The SKY18106-455LF consists of an SP8T switch, GSM transmit
signal harmonic filters, and a serial peripheral interface (SPI)
controller. The low current consumption of the device makes it
very suitable for battery-operated applications.
The switch is provided in a compact 3.0 x 3.8 mm Quad Flat NoLead (QFN) package. A functional block diagram is shown in
Figure 1. The pin configuration and package are shown in
Figure 2. Signal pin assignments and functional pin descriptions
are provided in Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201162P • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • June 16, 2015
1
VDD
SPI_VDD
SPI_FRM
SPI_CLK
SPI_DATA
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
26
25
24
23
22
2
20
TRX1
GND
3
19
GND
TRX5
4
18
TRX2
GND
5
17
GND
TRX4
6
16
TRX3
GND
7
15
GND
GND
8
14
ANT
9
10
11
12
13
GND
TRX6
2G_HB_TX
GND
GND
21
GND
1
2G_LB_TX
GND
S1738
Figure 2. SKY18106-455LF Pinout – 26-Pin QFN
(Top View)
Table 1. SKY18106-455LF Signal Descriptions (1 of 2)
Pin
Name
Description
Pin
Name
Description
1
GND
Ground
10
GND
Ground
2
TRX6
3G WCDMA transmit arm 6. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
11
GND
Ground
3
GND
Ground
12
2G_HB_TX
High band GSM transmit. This pin is either connected
directly to or is disconnected from pin 14, depending
on the control data applied to pin 22.
4
TRX5
3G WCDMA transmit arm 5. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
13
GND
Ground
5
GND
Ground
14
ANT
Antenna port. This pin is either connected directly to
or is disconnected from pins 2, 4, 6, 9, 12, 16, 18, or
20, depending on the control data applied to pin 22.
6
TRX4
3G WCDMA transmit arm 4. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
15
GND
Ground
7
GND
Ground
16
TRX3
3G WCDMA transmit arm 3. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
8
GND
Ground
17
GND
Ground
9
2G_LB_TX
Low band GSM transmit. This pin is either connected
directly to or is disconnected from pin 14, depending
on the control data applied to pin 22.
18
TRX2
3G WCDMA transmit arm 2. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Table 1. SKY18106-455LF Signal Descriptions (2 of 2)
Pin
Name
Description
Pin
Name
Description
19
GND
Ground
23
SPI_CLK
SPI clock signal.
20
TRX1
3G WCDMA transmit arm 1. This pin is either
connected directly to or is disconnected from pin 14,
depending on the control data applied to pin 22.
24
SPI_FRM
SPI enable signal (slave select).
21
GND
Ground
25
SPI_VDD
SPI power supply for all slave devices (1.8 V nominal).
22
SPI_DATA
SPI data signal for read/write access.
26
VDD
Battery supply voltage input.
Electrical and Mechanical Specifications
controlled as described in Table 6. The switch may also be used
in one of three modes: active, standby, and isolation. These
modes are controlled by bits [15:11] of the SPI data word.
The absolute maximum ratings of the SKY18106-455LF are
provided in Table 2. Electrical specifications are provided in
Table 3.
NOTE: The SPI_VDD signal (pin 25) must be pushed high for 2 ms
before the first SPI command is sent to program the switch
within the operating temperature range (TOP).
Table 4 provides the format of the 30-bit SPI_DATA signal.
Table 5 describes the values assigned to the contents of the
SPI_DATA signal.
The SKY18106-455LF can operate in one of 16 states as listed in
Table 6. When VDD is high, the switch is active and its state is
Table 2. SKY18106-455LF Absolute Maximum Ratings (Note 1)
Maximum
Units
Supply voltage
Parameter
VDD
Symbol
Minimum
Typical
7
V
Input power
PIN
+36
dBm
Storage temperature
TSTG
–50
+100
C
Operating temperature
TOP
–30
+85
C
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
3
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Table 3. SKY18106-455LF Electrical Specifications (Note 1) (1 of 2)
(VDD = 2.75 V, TOP = +25 C, SPI_VDD = 1.8 V, All Ports Terminated With a 50 Ω Load, Unless Otherwise Noted)
Parameter
Symbol
Typical
Max
Units
2G_TX_LB, 824 to 915 MHz
0.75
0.85
dB
2G_TX_HB, 1710 to 1910 MHz
0.90
1.00
dB
2G_TX_LB, 824 to 915 MHz
0.85
0.95
dB
2G_TX_HB, 1710 to 1910 MHz
1.00
1.10
dB
1920 to 2170 MHz
0.75
0.85
dB
1920 to 2170 MHz
0.85
0.95
dB
1710 to 1990 MHz
0.7
0.8
dB
1710 to 1990 MHz
0.8
0.9
dB
Insertion loss, TRX arms (Bands 5 and 8)
824 to 960 MHz
0.50
0.65
dB
Insertion loss, TRX arms (Bands 5 and 8)
TOP = +85 °C
0.60
0.75
dB
Insertion loss, 2G
Insertion loss, 2G
Test Condition
Min
TOP = +85 °C
Insertion loss, TRX arms (Band 1)
Insertion loss, TRX arms (Band 1)
TOP = +85 °C
Insertion loss, TRX arms (Bands 2 and 3)
Insertion loss, TRX arms (Bands 2 and 3)
TOP = +85 °C
824 to 960 MHz
Isolation
2G_TX_LB to ANT,
824 to 915 MHz
2G_TX_HB to ANT,
1710 to 1910 MHz
2G_TX_HB/2G_TX_LB to any
TRX port
25
28
dB
30
35
dB
25
30
dB
Isolation, ANT to all “off” TRX ports
@ 2170 MHz
20
25
dB
Isolation, TRX to all “off” TRX ports
@ 2170 MHz
20
23
dB
Return loss
ANT port
15
20
dB
Harmonics
2fo and 3fo
Third order intermodulation distortion,
all TRX ports to ANT port
IMD3
2G_TX_LB to ANT, +35 dBm
2G_TX_LB to ANT, +35 dBm,
ANT VSWR = 4:1
–46
–42
dBm
–36
–33
dBm
2G_TX_HB to ANT, +33 dBm
2G_TX_HB to ANT, +33 dBm,
ANT VSWR = 4:1
–46
–42
dBm
–36
–33
dBm
3G TRX ports to ANT, +26 dBm
3G TRX ports to ANT, +26 dBm,
ANT VSWR = 4:1
–55
–50
dBm
–50
–45
dBm
–102
–97
dBm
All blockers, all phase angles,
transmit power = +15 dBm,
blocker power = –20 dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Table 3. SKY18106-455LF Electrical Specifications (Note 1) (2 of 2)
(VDD = 2.75 V, TOP = +25 C, SPI_VDD = 1.8 V, All Ports Terminated With a 50 Ω Load, Unless Otherwise Noted)
Parameter
Symbol
Harmonics attenuation (low band)
Test Condition
2fo
2 harmonics attenuation,
2G_TX_LB to ANT
3rd harmonics attenuation,
2G_TX_LB to ANT
4th harmonics attenuation,
2G_TX_LB to ANT
3fo
4fo
Harmonics attenuation (high band)
2 harmonics attenuation,
2G_TX_HB to ANT
3rd harmonics attentuation,
2G_TX_HB to ANT
4th harmonics attenuation,
2G_TX_HB to ANT
3fo
4fo
Switching speed
VDD
Supply current:
active mode
standby mode
IDD
Typical
Units
22
dB
24
dB
16
dB
24
dB
22
dB
16
dB
Path to path
2
μs
Standby to any “on” path
6
μs
2.75
6.00
V
500
3
800
μA
μA
2.65
Control voltage
SPI VDD high
1.6
1.8
2.0
V
SPI VDD low
–0.3
0
+0.3
V
SPI VDD x 70%
1.8
SPI VDD + 0.3
V
0
SPI VDD x 30%
V
SPI control input voltage high
SPI control input voltage low
Voltage standing wave ratio, all ports
Max
nd
2fo
Supply voltage
Min
nd
VSWR
1:2
Inband ripple, all ports
1:5
–
0.2
dB
Note 1: Performance is guaranteed only under the conditions listed in this table.
Table 4. Data Bit Format (SPI_DATA Signal)
29
28
A13
A12
R/W
27
26
25
24
A11
A10
A9
A8
Address
(Slave Type)
23
22
21
20
19
A7
A6
A5
A4
A3
Address
(Slave Identifier)
18
17
16
A2
A1
A0
Address
(Slave SPI Register)
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Data Bits
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
5
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Table 5. Data Bit Descriptions (SPI_DATA Signal)
Bit
Bit ID
Function
Value (Binary)
Description
29
A13
Read/write mode
0 or 1
“1” = read, “0” = write
28
A12
27
A11
26
A10
1
25
A9
0
24
A8
0
23
A7
22
A6
1
21
A5
0
20
A4
0
19
A3
0
18
A2
17
A1
0
16
A0
0
0
Address (Slave Type)
Address (Slave Identifier)
Address (Slave SPI Register)
0
0
0
15
D15
Active mode on or off
1 or 0
14
D14
Data bit select 4 (MSB)
–
13
D13
Data bit select 3
–
12
D12
Data bit select 2
–
11
D11
Data bit select 1 (LSB)
–
10
D10
–
9
D9
–
8
D8
–
7
D7
–
6
D6
–
5
D5
4
D4
–
3
D3
–
2
D2
–
1
D1
–
0
D0
–
Not used
–
001 used for the SKY18106-455LF
Non-volatile value programmed by vendor
Not used
See Table 6
Reserved
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Table 6. SKY18106-455LF Truth Table (SPI_DATA, Bits [15:11])
Active Mode
Bias
State
Bit[15]
Bit[14]
Bit[13]
Bit[12]
Bit[11]
Switch disabled (low current mode/standby mode)
0
0
0
0
0
2
GSM high band
1
0
0
0
1
3
GSM low band
1
0
0
1
0
4
Reserved
1
0
0
1
1
5
TRX1
1
0
1
0
0
6
TRX2
1
0
1
0
1
7
TRX3
1
0
1
1
0
8
Reserved
1
0
1
1
1
9
TRX4
1
1
0
0
0
10
TRX5
1
1
0
0
1
11
TRX6
1
1
0
1
0
12
Reserved
1
1
0
1
1
13
Reserved
1
1
1
0
0
14
Reserved
1
1
1
0
1
15
Reserved
1
1
1
1
0
16
Isolation state
1
1
1
1
1
1
Band
SPI Data Word
Evaluation Board
Package and Handling Information
The SKY18106-455LF Evaluation Board is used to test the
performance of the SKY18106-455LF Antenna Switch. An
Evaluation Board schematic diagram is provided in Figure 3. An
assembly drawing for the Evaluation Board is shown in Figure 4.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Package Dimensions
The SKY18106-455LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
The PCB layout footprint for the SKY18106-455LF is provided in
Figure 5. Typical part markings are shown in Figure 6. Package
dimensions for the 26-pin QFN are shown in Figure 7, and tape
and reel dimensions are provided in Figure 8.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
7
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
SPI Enable Signal
SPI Power Supply
SPI Clock Signal
C1
10 nF
SPI Data Signal
6
Transmit/Receive RF Port 4
7
8
Transmit/Receive RF Port 1
SPI_DATA
19
GND
GND
TRX5
TRX2
18
Transmit/Receive RF Port 2
17
GND
GND
TRX4
TRX3
16
Transmit/Receive RF Port 3
15
GND
GND
GND
9
10
11
12
C3
4.5 pF
14
ANT
GND
5
21
GND
20
2G_HB_TX
4
Transmit/Receive RF Port 5
22
TRX1
GND
3
23
TRX6
GND
2
Transmit/Receive RF Port 6
GND
2G_LB_TX
1
24
SPI_CLK
25
VDD
26
SPI_FRM
C2
10 nF
SPI_VDD
Battery Supply Voltage
Antenna
L1
18 nH
L2
18 nH
13
GSM RF Port, Low Band
GSM RF Port, High Band
Notes: Components L1, L2, and C3 are recommended for ESD protection.
No DC blocking capacitors are needed on the RF ports.
S1978
Figure 3. SKY18106-455LF Evaluation Board Schematic
C4
C3
C2
C1
D
SPI_VD
VDD
M
SPI_
CLK
SPI_
DAT
A
C5
SPI_FR
TRX6
TRX1
TRX5
TRX2
TRX4
TRX3
ANT
2G_LB_TX
2G_HB_TX
S1973
Figure 4. SKY18106-455LF Evaluation Board Assembly Drawing
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Pin 26
2X 0.928
16X 1.23
R0.2
26X 0.42
Pin 1
26X 0.2
0.4 Pitch
0.2
2X 1.328
Stencil aperture size for center ground
pad should be 80% to 100% (by area)
of the solder mask opening
10X 1.63
Package Outline
Stencil Aperture
Top View
7X 1.23
16X 1.18
Pin 26
14X 0.42
Pin 26
Pin 1
26X 0.52
Pin 1
26X 0.3
0.25 Typ
14X 0.2
0.4 Pitch
0.2
0.4 Pitch
7X 1.63
Thermal Via Array will
improve thermal performance.
0.2
2X 1.328
Package Outline
Metallization
Top View
16X 1.58
2X 0.928
Package Outline
Solder Mask Opening
Top View
All measurements are in millimeters
S1984
Figure 5. SKY18106-455LF PCB Layout Footprint
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
9
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Skyworks Part #
Lot #
Date Code:
(YY = Calendar Year
WW = Week
CC = Country Code)
Pin 1
Indicator
Figure 6. Typical Case Markings
(Top View)
Seating Plane
3.00
A
Pin 1
Indicator
1.855 +0.10/–0.15
C
B
26X 0.25 Min.
0.02 + 0.03/–0.02
R0.2
2.655 +0.10/–0.15
Detail A
3.80
0.10 C
2X
0.75 ± 0.05
26X
2X
0.10 C
0.10 C
Top View
3
0.08 C
Side View
0.40 Pitch
Bottom View
0.27 ± 0.1
0.2 ± 0.05
0.10 M C A B
Detail A
Scale: 80X
26 Places
5
All measurements are in millimeters.
Dimensioning and tolerancing according to ASME Y14.5M-1994.
Coplanarity applies to the terminals and all other bottom surface metalization.
Dimension applies to metalized terminal and is measured between 0.15 mm
and 0.30 mm from terminal tip.
Figure 7. SKY18106-455LF 26-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
S2413
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
0.30 ± 0.05
2.00 ± 0.05
4.00 ± 0.10
B
∅1.50 +0.10
–0.00
1.75 ± 0.10
1.10 ± 0.10
A
B
8.00 ± 0.10
12.00 ± 0.30
A
5.50 ± 0.05
4.10 ± 0.10 (Bo)
Pin 1
Indicator
∅1.50 Min
Section B
3.30 ± 0.10 (Ao)
Direction of Feed
Section A
Notes:
1. Carrier tape must meet all requirements of Skyworks GP01-D233 procurement spec for tape and reel shipping.
2. Carrier tape: black conductive polycarbonate or polystyrene.
3. Cover tape: transparent conductive material.
4. ESD-surface resistivity is ≤1 x 1010 Ohms/square per EIA, JEDEC TNR Specification.
5. Ten-sprocket hole pitch cumulative tolerance: ±0.20 mm.
6. Ao and Bo measured on plane 0.30 mm above the bottom of the pocket.
7. All measurements are in millimeters.
Y2093
Figure 8. SKY18106-455LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
June 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201162P
11
DATA SHEET • SKY18106-455LF: SP8T ANTENNA SWITCH
Ordering Information
Model Name
SKY18106-455LF: SP8T Antenna Switch
Manufacturing Part Number
SKY18106-455LF
Evaluation Board Part Number
EN31-D655-001_V1
Copyright © 2010- 2013, 2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com