200745C.pdf

DATA SHEET
SKY13306-313LF: GaAs SPDT Switch 100 MHz–6 GHz
Features
●
●
●
●
●
●
Functional Block Diagram
Broadband: 100 MHz – 6 GHz
Very low insertion loss: 0.5 dB typ. 2.4–2.5 GHz
High linearity: IIP3 = 53 dBm typ. 3 V
Low current consumption: <50uA @ 3 V
Miniature QFN-6 2 x 3 mm package
Lead (Pb)-free and RoHS-compliant MSL1 @ 260 C per
JEDEC J-STD-020
J2
1
6
V1
GND
2
5
J1
J3
3
4
V2
Description
The SKY13306-313LF is an IC FET SPDT switch in a low-cost
miniature QFN- 6 plastic package. The SKY13306-313LF features
low insertion loss, excellent linearity and positive voltage operation
with very low DC power consumption. This general purpose switch
can be used in a variety of telecommunications applications, and
was designed for use as a transmit-receive switch for WLAN applications such as 802-11a/b/g. The QFN-6 package is lead (Pb)-free
and meets all current requirements for RoHS.
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Product is in development stages, performance is based on simulation, and pin out and package are advanced and may change.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200745 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 11, 2008
1
DATA SHEET • SKY13306-313LF
Electrical Specifications
T = 25 °C, VCTL = 0/3 V, ZO = 50 Ω, unless otherwise noted
Parameter
Condition
Frequency
Min.
Insertion loss
J1–J2, J1–J3
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
Isolation
J1–J2, J1–J3
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
Return loss
Insertion loss state
0.10 GHz–6.00 GHz
2.40 GHz–2.50 GHz
3.40 GHz–3.60 GHz
5.15 GHz–5.85 GHz
Input power for 0.1 dB compression
21
22
23
21
Typ.
Max.
Unit
0.6
0.5
0.5
0.6
0.9
0.7
0.7
0.8
dB
dB
dB
dB
25
25
26
24
dB
dB
dB
dB
15
25
16
15
dB
dB
dB
dB
2.4 GHz–2.5 GHz
35
dBm
2nd Harmonic
PIN = 22 dBm
2.45 GHz
-70
dBc
3rd Harmonic
PIN = 22 dBm
2.45 GHz
-68
dBc
Input 3rd order intercept point
Two tones, 15 dBm each tone, 5 MHz spacing
5.2 GHz
53
dBm
Control voltage
VHIGH
VLOW
2.7
-0.25
Control port current
VCTL = 3 V
VCTL = 5 V
VCTL = 0 V
10
15
10
Value
RF input power @ 0,5 V
36.5 dBm @ 25 °C
RF input power @ 0,3 V
36 dBm @ 25 °C
Control voltage
V
V
100
200
50
µA
µA
µA
Truth Table
Absolute Maximum Ratings
Characteristic
5
0.25
-0.2 V < VCTL < 6 V
Operating temperature range
-40 °C to +85 °C
Storage temperature range
-65 °C to +150 °C
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
V1(1)
V2(1)
J1–J2
J1–J3
0
VHIGH
Isolation
Insertion loss
VHIGH
0
Insertion loss
Isolation
All other conditions not recommended. No damage to the switch will occur if a nonrecommended combination of control voltages is present. The switch will not provide full
isolation or minimum insertion loss under such conditions.
1. 2.7 V < VHIGH < 5 V.
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
April 11, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200745 Rev. C
DATA SHEET • SKY13306-313LF
Typical Performance Data
T = 25 °C, VCTL = 0/3 V, ZO = 50 Ω, unless otherwise noted
J1-J2
0
J1-J3
-0.2
-10
Isolation (dB)
-0.6
Loss (dB)
J1-J3
-5
-0.4
-0.8
-1.0
-1.2
-1.4
-15
-20
-25
-30
-1.6
-35
-1.8
-40
-2.0
0
1
2
3
4
0
6
1
2
3
4
Frequency (GHz)
Frequency (GHz)
Typical Insertion Loss
Typical Isolation
J1-J2 lS11l
J1-J2 lS22l
0
5
5
6
0
J1-J3 lS11l
J1-J3 lS33l
-0.1
-0.2
-5
-0.3
Loss (dB)
-10
Return Loss (dB)
J1-J2
0
-15
-20
-25
-0.4
-0.5
-0.6
-0.7
-30
-0.8
-35
-0.9
-40
-1
25
-45
-50
0
1
2
3
4
5
6
Frequency (GHz)
26
27
28
29
30
31
32
33
34
35
Input Power (dBm)
Typical Compression at 2.4 GHz
Typical Return Loss Insertion Loss State
(
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200745 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 11, 2008
3
DATA SHEET • SKY13306-313LF
QFN-6
Pin Out and Suggested Circuit
0.078 (2.00 mm)
BSC
Pin 1
Indicator
0.29 x 0.35
1
0.039
(1.00 mm) Max.
0.001
(0.025 mm)
± 0.001
(0.025 mm)
6
0.118
2
5 (3.00 mm)
BSC
12˚ Max.
4
3
Top View
Side View
1.02
GND
J3
1
6
2
5
CBL
V1
CBL
3
CBL
4
J1
V2
DC blocking capacitors (CBL) must be supplied externally.
CBL = 15 pF.
0.35 ± 0.08 mm
1
6
0.95 BSC
J2
5
2
4
3
0.64 BSC
0.05 ± 0.05
Bottom View
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
April 11, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200745 Rev. C
DATA SHEET • SKY13306-313LF
Copyright © 2007, 2008, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and
names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are
incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200745 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • April 11, 2008
5