SKY13354_368LF_201425D.pdf

DATA SHEET
SKY13354-368LF: 0.1 to 3.0 GHz Dual SPDT Crossed Switch
RF1A
Applications
 Cellular infrastructures
RFCA
RF1B
Features
 Broadband frequency range: 0.1 GHz to 3.0 GHz
 Positive voltage control: 1.6 V to 5.0 V
 Low insertion loss
 High isolation
 High P0.2dB
RF2B
 Ultra-miniature, QFN (12-pin, 2 x 2 mm) package
(MSL1, 260 C per JEDEC J-STD-020)
RF1A
V2
N/C
11
10
RFCA
N/C
2
8
N/C
RF2A
3
7
RFCB
5
6
N/C
9
V1
1
RF2B
RF1B
4
S2246
Figure 1. SKY13354-368LF Block Diagram
Skyworks Green™ products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of Green™, document number
SQ04-0074.
12
RFCB
RF2A
Description
The SKY13354-368LF is a pHEMT GaAs dual single-pole, doublethrow (SPDT) crossed switch designed for cellular infrastructure
band switching applications. The internal crossed switch
arrangement is designed to switch balanced RF filters.
Switching is controlled by two control voltage inputs (V1 and V2).
Depending on the logic voltage level applied to the control pins,
the RFCA and RFCB pins are each connected to one of four
switched RF outputs (RF1A, RF1B, RF2A, or RF2B) using a low
insertion loss path, while maintaining a high isolation path to the
alternate port DC blocking capacitors are required on all RF ports.
The switch is a “reflective short” on the isolated port.
The switch is manufactured in a compact, 2 x 2 mm, 12-pin
exposed pad plastic Quad Flat No-Lead (QFN) package.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
S2247
Figure 2. SKY13354-368LF Pinout
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201425D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 16, 2015
1
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Table 1. SKY13354-368LF Signal Descriptions
Pin
Note:
Name
Description
Pin
Name
Description
1
RF1B
RF port 1B. Must be DC blocked for proper
operation.
7
RFCB
RF common port B (antenna). Must be DC
blocked for proper operation.
2
N/C
No connection. May be connected to ground
with no change in performance.
8
N/C
No connection. May be connected to ground
with no change in performance.
3
RF2A
RF port 2A. Must be DC blocked for proper
operation.
9
RFCA
RF common port A (antenna). Must be DC
blocked for proper operation.
4
RF2B
RF port 2B. Must be DC blocked for proper
operation.
10
N/C
No connection. May be connected to ground
with no change in performance.
5
V1
DC control voltage 1. See Table 5.
11
V2
DC control voltage 2. See Table 5.
6
N/C
No connection. May be connected to ground
with no change in performance.
12
RF1A
RF port 1A. Must be DC blocked for proper
operation.
Bottom ground paddle must be connected to ground through a low impedance path.
Electrical and Mechanical Specifications
Typical performance characteristics of the SKY13354-368LF are
illustrated in Figures 3 through 8.
The absolute maximum ratings of the SKY13354-368LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3 and electrical specifications are provided in
Table 4.
The state of the SKY13354-368LF is determined by the logic
provided in Table 5.
Table 2. SKY13354-368LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
+30
dBm
6
V
Input power
PIN
Control voltage
V1, V2
Storage temperature
TSTG
–40
+125
C
Operating temperature
TOP
–40
+85
C
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. SKY13354-368LF Recommended Operating Conditions
Parameter
Symbol
Minimum
Frequency
f
0.1
Control voltage (V1, V2)
VCTL
1.6
Typical
3.0
Maximum
Units
3.0
GHz
5.0
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
September 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201425D
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Table 4. SKY13354-368LF Electrical Specifications (Note 1)
(V1 = V2 = 0 V and +2.7 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
0.40
0.50
0.55
0.55
0.65
0.90
dB
dB
dB
RF Specifications
Insertion loss
IL
RFCA to RF1A/2A,
RFCB to RF1B/2B,
VCTL = 1.6 to 5.0 V:
0.1 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 3.0 GHz
Isolation
Iso
RFCA to RF1A/2A,
RFCB to RF1B/2B,
VCTL = 1.6 to 5.0 V:
0.1 to 1.0 GHz
1.0 to 2.0 GHz
2.0 to 3.0 GHz
24
25
20
29
30
32
dB
dB
dB
15
22
dB
VCTL = 1.6 V
VCTL = 1.8 V
VCTL = 2.0 V
VCTL = 2.7 V
VCTL = 5.0 V
+17
+20
+23
+28
+33
dBm
dBm
dBm
dBm
dBm
0.1-3.0 GHz, f = 1 MHZ,
PIN = +15 dBm/tone
+55
dBm
50% VCTL to 90/10% RF,
90/10% RF or 10/90% RF
40
40
ns
ns
Return loss
|S11|
0.1-3.0 GHz,
VCTL = 1.6 to 5.0 V
0.2 dB compression point
P0.2dB
0.1-3.0 GHz:
Third order input intercept point
IIP3
Switching speed
DC Specifications
Control voltage:
Low
High
VCTL_L
VCTL_H
Control current
ICC
–0.2
1.6
0
2.7
+0.2
5.0
5
V
V
μA
Note 1: Performance is guaranteed only under the conditions listed in this table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201425D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 16, 2015
3
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Typical Performance Characteristics
(V1 = V2 = 0 V and +1.6 V, TOP = +25 C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
+10
0
RFCA to RF1A
RFCA to RF2A
RFCB to RF1B
RFCB to RF2B
–0.3
0
–10
–0.8
Isolation (dB)
Insertion Loss (dB)
–0.5
–1.0
–1.3
–30
–1.5
RFCA to RF1A
RFCA to RF2A
RFCB to RF1B
RFCB to RF2B
–1.8
–2.0
0.25
–20
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25
–40
–50
0.25
3.50
0.50
0.75
1.00
1.25
Frequency (GHz)
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25
3.50
3.00
3.25
3.50
Frequency (GHz)
Figure 3. Insertion Loss vs Frequency
Figure 4. Isolation vs Frequency
0
0
–5
–5
–10
–10
Return Loss (dB)
Isolation (dB)
–15
–20
–25
–30
–35
–15
–20
–25
–30
–40
–35
–45
–50
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.25
–40
0.25
3.50
Frequency (GHz)
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
Frequency (GHz)
Figure 5. Isolation vs Frequency
(RFCA to RFCB)
Figure 6. Return Loss vs Frequency
+34
+0.1
+30
–0.1
P0.2dB (dBm)
Normalized Insertion Loss (dB)
+32
0
–0.2
VCTL = 1.6 V
VCTL = 1.7 V
VCTL = 1.8 V
VCTL = 2.0 V
VCTL = 2.7 V
VCTL = 5.0 V
–0.3
–0.4
+10
+12
+14
+16
+18
+20
+22 +24
+26
+28
+30
+32
+34
Input Power (dBm)
Figure 7. Normalized Insertion Loss vs Input Power
VCTL = 1.8 V
VCTL = 2.0 V
VCTL = 2.7 V
VCTL = 5.0 V
+26
+24
+22
+20
–0.5
+8
+28
+36
+18
–50
–40
–30
–20
–10
0
+10 +20
+30 +40 +50 +60 +70 +80 +90 +100
Temperature (°C)
Figure 8. P0.2dB vs Temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
September 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201425D
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Table 5. SKY13354-368LF Truth Table
Note:
V1 (Pin 5)
V2 (Pin 11)
Insertion Loss Paths
1
0
RFCA to RF1A
RFCB to RF1B
0
1
RFCA to RF2A
RFCB to RF2B
“1” = +1.6 V to +5 V. “0” = 0 V to +0.2 V. Any state other than described in this table places the switch into an undefined
state. An undefined state will not damage the device.
Evaluation Board Description
Package and Handling Information
The SKY13354-368LF Evaluation Board is used to test the
performance of the SKY13354-368LF Dual SPDT Switch. An
Evaluation Board schematic diagram is provided in Figure 9. An
assembly drawing for the Evaluation Board is shown in Figure 10.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
The SKY13354-368LF is rated to Moisture Sensitivity Level 1
(MSL1) at 260 C. It can be used for lead or lead-free soldering.
For additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Package Dimensions
The PCB layout footprint for the SKY13354-368LF is provided in
Figure 11. Typical part markings are shown in Figure 12. Package
dimensions are shown in Figure 13, and tape and reel dimensions
are provided in Figure 14.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
CBLK
RF Port 1A
1
×
CBLK
2
V2
RFCA
N/C
N/C
RF2A
RFCB
4
RF Port 2B
V1
RF2B
3
RF1B
5
CBLK
9
8
7
RF Common
Port A (Antenna)
×
CBLK
RF Common
Port B (Antenna)
N/C
CBLK
RF Port 1B
10
N/C
11
RF1A
12
RF Port 2A
DC Control
Voltage 2
×
6
×
DC Control
Voltage 1
S2258
Figure 9. SKY13354-368LF Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201425D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 16, 2015
5
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
RF1A
V2
RF1B
RFCA
RF2A
RFCB
RF2B
V1
S2248
Figure 10. SKY13354-368LF Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
September 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201425D
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
16X 0.71
Part Outline
16X 0.44
R0.20
Pin 1 Indicator
16X 0.20
0.40 Pitch
2X 0.46
2X 0.46
Exposed Solder
Area, Typical
S1802
All measurements in millimeters
Figure 11. SKY13354-368LF PCB Layout Footprint
(Top View)
Pin 1
Indicator
Skyworks Part #
Figure 12. Typical Part Markings
(Top View)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201425D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 16, 2015
7
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Seating
Plane
–C–
2.00
0.92 +0.10/–0.15
–A–
(0.460)
0.02 +0.03/–0.02
–B–
Pin 1
Indicator
Detail A
R0.20
Pin 1 Indicator
Pin 1
0.40
2.00
0.92 +0.10/–0.15
(0.460)
0.10 C
2X
0.55 + 0.05/–0.04
2X
0.10 C
0.10 C
Top View
Side View
12X 3
0.08 C
Exposed Pad
12X 0.20 Min.
Bottom View
0.29 ± 0.10
Notes:
1.
2.
3.
4.
5.
All measurements are in millimeters.
Dimensions and tolerances according to ASME Y14.5M-1994.
Coplanarity applies to the terminals and all other bottom surface metallization.
Plating requirement per source control drawing (SCD) 2504.
Dimension applies to metallized terminal and is measured between 0.15 and 0.30 mm
from terminal tip.
0.2 ± 0.05
0.10 M C A B
Detail B
0.10 M C
5
Figure 13. SKY13354-368LF 12-Pin QFN Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
September 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201425D
S1731
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
2.00 ± 0.05
Ø1.50 + 0.10/–0.00
4.00 ± 0.10
7º
1.75 ± 0.10
Pin 1
0.23 ± 0.05
A
2.25 ± 0.05
3.50 ± 0.05
8.00 ± 0.20
0.70 ± 0.05 (Ko)
Section A
B
4.00 ± 0.10
A
B
7º
2.25 ± 0.05
Section B
Notes:
1.
2.
3.
4.
5.
Carrier tape must meet all requirements of Skyworks GP01-D232 procurement spec for tape and reel shipping.
Carrier tape shall be black conductive polycarbonate bakeable material at 125 ˚C temperature.
Cover tape shall be transparent conductive with 5.40 mm width.
ESD-surface resistivity must meet all ESD requirements of Skyworks specified on GP01-D232.
All measurements are in millimeters.
ts737
Figure 14. SKY13354-368LF Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201425D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 16, 2015
9
DATA SHEET • SKY13354-368LF: DUAL SPDT CROSSED SWITCH
Ordering Information
Model Name
SKY13354-368LF Dual SPDT Crossed Switch
Manufacturing Part Number
SKY13354-368LF
Evaluation Board Part Number
SKY13354-368LF-EVB
Copyright © 2010-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
September 16, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201425D