Errata: CS4205 Rev. B0

Errata: CS4205 Rev. B0
(Reference CS4205 Data Sheet revision DS489PP2)
Functional Problems
General issues
1.
The analog reference will not start if a clock is being driven into XTL_IN before power is
applied to the device. Actual application circuits must be designed so that the external clock
generator does not start running before the codec is powered up.
This problem only occurs in what is considered an invalid operational mode (outside data
sheet requirements) and will not be addressed in silicon.
2.
Playback and capture at 9.6 kHz, 13.714 kHz, and 24 kHz is not supported. Selecting these
rates in any of the sample rate control registers will cause the corresponding SRC to operate
at the nearest supported rate (11.025 kHz, 16 kHz, and 22.05 kHz respectively).
Software workaround possible in driver.
3.
Enabling the Loudness function (reg 20h, bit D12) does not add the desired amount of bass
and treble gain. Software can compensate for this problem by applying more bass and treble
gain using the Master Tone Register (Index 08h).
Software workaround possible in driver.
Powerdown issues
4.
During PR4+PR5, a GPIO wakeup event will drive SDATA_IN 'high'. Software should
disable GPIO interrupts before entering PR4+PR5.
Software workaround possible in driver.
5.
During PR5 and PR4+PR5, SCLK is driven 'high'. Software should disable SCLK (clear
SDSC bit in reg 6Ah) or the serial data port (clear SDEN bit in reg 6Ah) before entering PR5
or PR4+PR5.
Software workaround possible in driver.
Cirrus Logic
P.O. Box 17847, Austin, Texas 78760
(512) 445 7222 FAX: (512) 445 7581
http://www.cirrus.com
ER489D1
DEC ‘01
1
6.
During primary PR4, SDOUT and SDO2 keep transmitting the last serial data sample if the
source of the serial data is the AC-link (SDOS=00 in reg 5Eh). Software can prevent this
problem if it disables the serial data port (clear SDEN bit in reg 6Ah) before entering primary
PR4.
Software workaround possible in driver.
7.
During secondary PR4 sleep state, the serial data port clocks (LRCLK, and SCLK) will be
driven to last active state instead of 'low'. Software can prevent this problem if it disables the
serial data port (clear SDEN bit in reg 6Ah) before entering secondary PR4 sleep state.
Software workaround possible in driver.
Performance Problems
Pops and clicks
8.
Clearing PR1 causes a click if the DAC path is unmuted. Software can prevent this problem
by muting the PCM Out Volume (reg 18h) (if DDM=0) or muting the Master Out Volume
(reg 02h) and Mono Out Volume (reg 06h) (if DDM=1) before clearing PR1.
Software workaround possible in driver.
9.
Clearing PR3 and RESET# low-high transition cause a pop.
An applications level workaround is possible by not loading Vrefout capacitively.
Analog performance
10. The MIC1/2 inputs show increased distortion above -2 dBV (0.8 Vrms) input voltage.
PC 99 and PC 2001 THD+N compliance testing is done at –3 dB input level, so this problem
will not affect certification.
Current consumption
11a. The clocking supply current (DVdd1) is too high during PR4+PR5 (2.7 mA) and during
RESET (0.5 mA).
11b. The analog supply current (AVdd1) is too high during PR3 (1.9 mA).
2
ER489D1
11c. The analog (AVdd1) and clocking (DVdd1) supply currents are too high when setting PR3
and PR4 and PR5 simultaneously. Software can prevent this problem by first setting PR3,
waiting for about 500 ms and then setting PR4+PR5.
Software workaround possible in driver.
Digital signal quality
12. BIT_CLK jitter is too high (about 2.5 ns).
There is sufficient setup time margin to compensate for this problem.
If there are any questions concerning this information,
please contact: 1-888-937-2787 or 1-512-912-3555
ER489D1