Download Data Sheet

DATA SHEET
VB SERIES
TO 3 WATTS
•
•
•
•
•
•
•
•
•
•
Surface mount
Efficiency up to 83%
2/1 input range (9 to 75 Vin)
1500VDC isolation
Continuous short-circuit protection
Tight line/load regulation
Single and dual outputs
MTBF > 1,000,000 hours minimum
UL/CUL 1950 safety approval
Water washable
This economically priced dc/dc converter offers
3 wide input ranges of 9-18, 18-36, and 36-75VDC.
It is suitable for telecom, process control, battery
backup, and other applications where tight
line/load regulation is required.
MODELS
INPUT
VOLTAGE
(VDC)
12
(9 - 18)
24
(18 - 36)
48
(36 - 75)
OUTPUT
VOLTAGE
(VDC)
OUTPUT
CURRENT
(mA)
EFFICIENCY
(%)
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
700
600
250
200
±300
±125
±100
700
600
250
200
±300
±125
±100
700
600
250
200
±300
±125
±100
75
79
82
82
78
81
81
76
80
83
83
79
82
82
76
80
83
83
79
82
82
MODEL NUMBER
VB12S3.3-2.3
VB12S5-3
VB12S12-3
VB12S15-3
VB12D5-3
VB12D12-3
VB12D15-3
VB24S3.3-2.3
VB24S5-3
VB24S12-3
VB24S15-3
VB24D5-3
VB24D12-3
VB24D15-3
VB48S3.3-2.3
VB48S5-3
VB48S12-3
VB48S15-3
VB48D5-3
VB48D12-3
VB48D15-3
8/2/2006
603 778 2300
www.wallindustries.com
1
DATA SHEET
VB SERIES
SPECIFICATIONS
TO 3 WATTS
All specifications apply at 25ºC unless otherwise noted.
SPECIFICATION
VALUE
INPUT
Input Voltage Range
Input Filter
9-18, 18-36, 36-75
Pi Filter
OUTPUT
Output Current
Voltage Accuracy
Line Regulation (HL-LL)
Load Regulation (10-100% load)
Short Circuit Protection
Ripple/Noise (20MHz BW)
Transient Response
see model information table
±0.5% typ., 1.0% max.
±0.3% max.
±0.3% typ., 1.0% max.
continuous
75 mV p-p max.
200 uS typ., 500uS max.
GENERAL
Efficiency
Isolation Voltage (input to output)
Isolation Resistance (500 VDC)
Switching Frequency
see model information table
1500 VDC
1000 M Ohms
300 kHz typ.
ENVIRONMENTAL
Operating Temperature (ambient)
Storage Temperature
Humidity (non-condensing)
Cooling
-40°C to +71°C (case 90°C)
-40°C to +125°C
95% max.
free air convection
PHYSICAL
Dimensions
Weight
Case Material
Flammability
1.27 x 0.74 x 0.4 inches
5.75 grams
non-conductive black plastic
UL94V-0
due to advances in technology, specifications subject to change without notice.
NOTES
1) Efficiency (%) measured at maximum load.
2) These converters require a minimum load to maintain specified regulation.
3) All dc/dc converters should be externally fused at the input side for protection,
consult factory for more information.
4) Other input and output voltages may be available, please consult factory for
more information.
5) Specifications subject to change without notice.
6) Operation under no-load conditions will NOT damage these converters however
they may not meet all listed specifications under such conditions.
7) Transient recovery time is measured to within 1% error band for a step change
in output load of 75% to 100%.
8/2/2006
603 778 2300
www.wallindustries.com
2
DATA SHEET
VB SERIES
TO 3 WATTS
Units are encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics
over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0
flammability specifications. Leads are tin plated for improved solderability.
8/2/2006
603 778 2300
www.wallindustries.com
3
DATA SHEET
VB SERIES
TO 3 WATTS
8/2/2006
603 778 2300
www.wallindustries.com
4
DATA SHEET
VB SERIES
TO 3 WATTS
8/2/2006
603 778 2300
www.wallindustries.com