1.
Scope
The present specifications shall apply to an FMB-G16L.
2.
Outline
Type
Silicon Schottky Barrier Diode
Structure
Resin Molded
Applications
Flammability : UL94V-0(Equivalent)
High Frequency Rectification
3. Absolute maximum ratings
No.
4.
Item
Symbol
Unit
Rating
1
Transient Peak Reverse Voltage
VRSM
V
60
2
Peak Reverse Voltage
VRM
V
60
3
Average Forward Current
IF(AV)
A
6.0
4
Peak Surge Forward Current
IFSM
A
50
5
I2t Limiting Value
I2t
A2s
12.5
6
Junction Temperature
Tj
°C
-40~+150
7
Storage Temperature
Tstg
°C
-40~+150
Conditions
Refer Derating of 6
10msec.
half sinewave, one shot
1msec≤t≤10msec
Electrical characteristics (Ta=25°C, unless otherwise specified)
No.
Item
Symbol
Unit
Value
Conditions
1
Forward Voltage Drop
VF
V
0.72 max.
IF=6.0A
2
Reverse Leakage Current
IR
mA
5.0 max.
VR=VRM
3
Reverse Leakage Current Under
High Temperature
H・IR
mA
200 max.
VR=VRM, Tj=150°C
4
Thermal Resistance
Rth (j-c)
°C /W
4.0 max.
Between Junction and case
040128
1/4
61426-01
SANKEN ELECTRIC CO., LTD.
5.
FMB-G16L
Characteristics
IF(AV) - PF
8
Tj=150°C
7
t
T
PF (W)
Forward Power Dissipation (W)
6
t/T=1/6
5
t/T=1/3,sinewave
4
3
DC
t/T=1/2
2
1
0
0
1
2
3
4
5
6
IF(AV) (A)
Average Forward Current (A)
VR - P R
10
Tj=150°C
t
PR (W)
Reverse Power Dissipation (W)
8
T
1-t/T=5/6
6
1-t/T=2/3
4
1-t/T=1/2
2
sinewave
0
0
10
20
30
VR (V)
40
50
60
Reverse Voltage (V)
040128
2/4
61426-01
SANKEN ELECTRIC CO., LTD.
6.
FMB-G16L
Derating
Tc - IF(AV)
VR=60(V)
6
DC
5
IF(AV) (A)
Average Forward Current (A)
t/T=1/6
4
t/T=1/3
3
t/T=1/2
2
Tj=150°C
Sinewave
1
t
T
0
50
100
150
Tc (°C)
Case Temperature (°C)
040128
3/4
61426-01
SANKEN ELECTRIC CO., LTD.
7.
FMB-G16L
Package information
7-1 Package type, physical dimensions and material
4.2
2.8
C 0.5
10.0
Ó
ƒ3 .3
4.0
8.4
16.9
※1
*12
※
*2
※3
0.8
¦2.6
1.35
3.9
¦ F

ª ³
¡

@
¦ Froot dimension
(13.5)
0.85
0.45
w
¦

È 
« 
ö 
· 
} 0.2
tolerance
| }0.2
\
}_O_
¦5.08
Dimensions in ㎜
7-2 Appearance
The body shall be clean and shall not bear any stain, rust or flaw.
7-3 Marking
Marking
Type Name
*1
*2
*3
Type Name
Polarity
Lot number
1st letter: Last digit of year
FMB-G16L
FMBG16
L
2nd letter: Month
From 1 to 9 for Jan. to Sep.,
O for Oct., N for Nov., D for Dec.
3rd & 4th letter: Day
ex. 4128
040128
(Jan. 28, 2004)
4/4
61426-01