http://datasheets.avx.com/TAC_LP.pdf

TACmicrochip®
Low Profile
FEATURES
•
•
•
•
The world’s smallest surface mount tantalum capacitor
CV range: 1.0-100μF / 2-16V
6 case sizes available in low profile option
Industrial and hi-rel medical applications
LEAD-FREE COMPATIBLE
COMPONENT
APPLICATIONS
• Industrial portable applications
L
CASE DIMENSIONS: millimeters (inches)
POLARITY BAND NOT TO
EXCEED CENTER LINE
H
S
Lt
W
MARKING
H, I, J, T, U, V CASE
Polarity
Band
(Anode+)
HOW TO ORDER
TAC
U
Type
TACmicrochip®
Case Size
See table
above
EIA
Code
EIA
Metric
L+0.20 (0.008)
-0.00 (0.000)
W+0.15 (0.006)
-0.00 (0.000)
%H
0805
2012-10
I
1206
3216-05
%J
0603
1608-08
2.00 (0.079)
3.20±0.20
(0.126±0.008)
1.60 (0.063)
1.35 (0.053)
1.60±0.20
(0.063±0.008)
0.85 (0.033)
T
1210
Code
3.50 ± 0.20
(0.138 ± 0.008)
3528-12
%U
0805
2012-06
V
1206
3216-08
2.00 (0.079)
3.20 ± 0.20
(0.126 ±0.008)
2.80 +0.20
-0.10
+0.008
(0.110 -0.004 )
1.35 (0.053)
1.60 ± 0.20
(0.063 ± 0.008)
Termination
Spacing(S)
Minimum
Termination
Length (Lt)
1.00 (0.039)
0.70 (0.028) min
0.15 (0.006)
0.50 (0.020)
1.80 (0.071) min. 0.15 (0.006)
0.75 (0.030)
0.55 (0.022) min
0.15 (0.006)
1.20 (0.047)
2.00 (0.079) min
0.15 (0.006)
0.60 (0.024)
0.70 (0.028) min
0.15 (0.006)
0.75 (0.030)
1.80 (0.071) min
0.15 (0.006)
H max
475
*
004
R
TA
Capacitance Code
pF code: 1st two digits
represent significant figures,
3rd digit represents multiplier
(number of zeros to follow)
Tolerance
K=±10%
M=±20%
Rated DC
Voltage
002=2Vdc
003=3Vdc
004=4Vdc
006=6.3Vdc
010=10Vdc
016=16Vdc
Packaging
R = 7" Standard Tin
Termination Plastic Tape
X = 41⁄4" Standard Tin
Termination Plastic Tape
A = 7" Gold Termination
Plastic Tape
F = 41⁄4" Gold Termination
Plastic Tape
Alternative
characters
may be used
for special
requirements
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Leakage Current DCL:
Rated Voltage (VR)
Category Voltage (VC)
Surge Voltage (VS)
Surge Voltage (VS)
Temperature Range:
Reliability:
Termination Finish:
48
ⱕ +85°C:
ⱕ +125°C:
ⱕ +85°C:
ⱕ +125°C:
All technical data relate to an ambient temperature of +25°C
0.1 μF to 100 μF
±10%; ±20%
0.01CV or 0.5μA whichever is the greater
2
3
4
6.3
10
16
1.3
2
2.7
4
7
10
2.7
3.9
5.2
8
13
20
1.7
2.6
3.2
5
8
12
-55°C to +125°C
1% per 1000 hours at 85°C, VR with 0.1Ω/V series impedance,
60% confidence level
Nickel and Tin Plating (standard),
Nickel and Gold Plating option available upon request
050916
TACmicrochip®
Low Profile
CAPACITANCE AND RATED VOLTAGE RANGE
(LETTER DENOTES CASE SIZE)
Capacitance
μF
Code
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
2.0V
105
155
225
335
475
685
106
156
226
336
476
686
107
3.0V
Voltage Rating DC (VR ) at 85°C
4.0V
6.3V
10V
16V
U
U
U
U
U
J
I
H
H
H/V
V
H
H
T
T
T
Available Ratings
Standard Height Profile: A, B, K, L, R Case
Low Profile: H, I, J, T, U, V Case
Note: Voltage ratings are minimum values. AVX reserves the right to supply
higher ratings in the same case size, to the same reliability standards.
RATINGS & PART NUMBER REFERENCE
AVX
Part No.
Case Capacitance
Size
(μF)
Rated
Voltage
(V)
Rated
Category Category
DCL
Temperature Voltage Temperature Max.
(ºC)
(V)
(ºC)
(μA)
TACU106*002#TA
U
10
2
85
TACH476*003#TA
H
47
3
85
TACU475*004#TA
TACJ106*004#TA
TACH336*004#TA
U
J
H
4.7
10
33
4
4
4
85
85
85
TACU335*006#TA
TACI106*006#TA
TACH156*006#TA
TACH226*006#TA
TACT686*006#TA
TACT107*006#TA
U
I
H
H
T
T
3.3
10
15
22
68
100
6.3
6.3
6.3
6.3
6.3
6.3
85
85
85
85
85
85
TACU225*010#TA
TACH106*010#TA
TACV106*010#TA
TACV156*010#TA
TACT476*010#TA
U
H
V
V
T
2.2
10
10
15
47
10
10
10
10
10
85
85
85
85
85
TACU105*016#TA
U
1
16
85
2 Volt @ 85°C
125
0.5
3 Volt @ 85°C
2
125
1.4
4 Volt @ 85°C
2.7
125
0.5
2.7
125
0.5
2.7
125
1.3
6.3 Volt @ 85°C
4
125
0.5
4
125
0.6
4
125
0.9
4
125
1.4
4
125
4.3
4
125
6.3
10 Volt @ 85°C
7
125
0.5
7
125
1.0
7
125
1.0
7
125
1.5
7
125
4.7
16 Volt @ 85°C
10
125
0.5
1.3
DF
Max.
(%)
ESR
Max.
@ 100kHz
(Ω)
MSL
8
5
20
100kHz RMS Current (mA)
Product
Category
25ºC
85ºC
125ºC
1
84
75
33
1
5
1
89
80
36
3
8
20
14
5
7.5
5
1
1
1
84
52
89
75
46
80
33
21
36
1
3
2
8
20
8
10
15
12
5
5
5
5
1
1
1
1
1
1
1
1
84
84
89
89
200
200
75
75
80
80
180
180
33
33
36
36
80
80
1
2
3
2
2
2
8
8
10
10
12
5
5
2
2
1
1
1
1
1
1
84
89
132
132
200
75
80
119
119
180
33
36
53
53
80
1
2
2
2
1
8
5
1
84
75
33
1
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts.
DCL is measured at rated voltage after 5 minutes.
For typical weight and composition see page 223.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
050916
49
TACmicrochip®
Low Profile
QUALIFICATION TABLE – CATEGORY 1
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TAC low profile series (Temperature range -55ºC to +125ºC)
Condition
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±10% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±5% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.2 x initial limit
ESR
1.2 x initial limit
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
DCL
ΔC/C
DF
ESR
Visual examination
DCL
ΔC/C
DF
ESR
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-10%
±5%
+10/-0%
+15/-0%
±5%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
IL*
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
IL*
no visible damage
initial limit
within ±10% of initial value
initial limit
initial limit
*Initial Limit
QUALIFICATION TABLE – CATEGORY 2
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TAC low profile series (Temperature range -55ºC to +125ºC)
Condition
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±15% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±10% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.2 x initial limit
ESR
1.2 x initial limit
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
DCL
ΔC/C
DF
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-15%
±5%
+15/-0%
+20/-0%
±5%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
IL*
ESR
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
IL*
Visual examination
DCL
ΔC/C
DF
ESR
no visible damage
1.5 x initial limit
within ±15% of initial value
1.5 x initial limit
1.5 x initial limit
*Initial Limit
50
050916
TACmicrochip®
Low Profile
QUALIFICATION TABLE – CATEGORY 3
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TAC low profile series (Temperature range -55ºC to +125ºC)
Condition
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±30% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
2 x initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±30% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.5 x initial limit
ESR
1.25 x initial limit
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
DCL
ΔC/C
DF
ESR
Visual examination
DCL
ΔC/C
DF
ESR
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-25%
±5%
+20/-0%
+25/-0%
±20%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
1.5 x IL*
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
1.5 x IL*
no visible damage
2 x initial limit
within ±30% of initial value
2 x initial limit
2 x initial limit
*Initial Limit
050916
51