Using Modular DC-DC Converters to Meet
European Standards for Railway Applications
In Europe, the performance of
electrical and electronic equipment in
railway applications is governed by
two international standards.
Electrical Requirements
for EN50155 (IEC571)
Operating Voltage Ranges. Table 1
lists the nominal input voltages (VN)
provided by power sources used for
railway applications.
The one most frequently cited in
design specifications is the document
IEC571, “Electronic Equipment on
Rail Vehicles,” also known as
European Norm EN50155, “Electronic
Equipment Used on Rolling Stock
Equipment.” In the U.K. the standard
that applies is RIA12, “General
Specification for Protection of Traction
and Rolling Stock Equipment from
Transients and Surges in DC Control
Systems,” developed by the Railway
Industries Association (RIA).
Equipment powered directly from
batteries with no voltage stabilizing
device must function properly with
input voltages that range from 0.7(VN)
to 1.25(VN) during normal operation.
The equipment must also withstand
input voltage drops of 0.6(VN) for
100ms and overvoltage surges of
1.4(VN) for one second that may occur
during startup.
While these two standards are similar
in most respects, the RIA12 standard
also requires a specific surge
withstanding capability.
Table 1 shows that, with some
exceptions, standard Vicor DC-DC
converters cover all of the specified
input ranges and transients.
The following discussion shows how
to comply with these standards using
modular Vicor DC-DC converters to
facilitate the design of complex power
supplies.
Fast Transient Specification.
Equipment must also be able to
withstand a direct transient of 1800V
lasting 50µs. The impedance of the
transient source is specified as 100Ω,
with transient energy around 100mJ.
Table 1—Input Specifications for EN50155 vs. Vicor DC-DC Converters
Nominal
Inputs
(VN)
Input
Ranges
0.7(VN)–1.25(VN)
24V
36V
48V
72V
96V
110V
17–30V
25–45V
34–60V
50–90V
67–120V
77–137V
Transients
Low (0.1s) High (1s)
0.6(VN)
1.4(VN)
14V
22V
29V
43V
58V
66V
34V
61V
67V
101V
135V
154V
Vicor
DC-DC Converter
Input Ranges
18–36V1
21–56V
36–76V2
55–100V3
66–160V
66–160V
To prevent damage to the DC-DC
converter, the module must be
connected to a suppression device,
such as a transient voltage suppressor
(TVS), directly across the input. A
TVS able to withstand up to 1.5J
would be suitable. The TVS’s
clamping voltage must be selected so
that it will not exceed the high line
voltage or transient limits of the
converter.
RIA12 Surge Protection
The RIA12 standard specifies that
equipment must withstand a 20ms
overvoltage surge 3.5 times greater
than the nominal input voltage. To
meet this standard, a suppression
circuit must be used with the DC-DC
converter.
For each of the standard input
voltages, the maximum input surges
are as follows:
VN
24V
36V
48V
72V
96V
110V
3.5(VN)
84V
126V
168V
252V
336V
385V
Since the source impedance of this
overvoltage pulse is 0.2Ω, a common
clamping device, such as a TVS, will
not provide a suitable solution because
the energy dissipated would be:
3.5(VN) – VZener
E = –––––––––––––
· VN · 0.02
0.2
Instead, an active circuit as shown in
Figure 1 is necessary.
1
Low limit at 18V
Low limit at 36V
3 Power derates to 75% of rated load at 45V
2
(continued)
VICOR CORPORATION
• 25 Frontage Road • Andover, MA 01810 • TEL: 800-735-6200 • FAX: 978-475-6715 • 4/96
Application Note
Q1
+ IN
+ OUT
1N4148
22k
R1
R2
22k
D1
1N4148
GATE
OUT
33k
D3
D2
470pF
500V
P = RDS(on) · IN2
The diodes D2 and D3 can have the
same breakdown voltage, in which
case the output (clamped) voltage will
equal D3 minus the gate source
voltage.
Q2
IRFD110
15V
10k
– OUT
– IN
Figure 1—An active circuit designed to prevent fast transients and surges.
Railway Standards
(page 2)
In this circuit, D1 clamps the fast, high
voltage spikes, while the active part
formed by D2, D3 and Q1, Q2 limits the
surge. During normal operation, Q1 is
kept in full conduction by the charge
pump circuit made up of the 1N4148
diodes and the 470pF capacitor. The
Gate Out signal from the converter
drives the charge pump.
When overvoltage occurs, the diode D2
conducts, with current limited by R1,
To select Q1 it is necessary to consider
the values of 3.5(VN) and the operating
current (IN) as well as the S.O.A. limits
for a single 20ms pulse. The RDS(on)
must also be taken into account, since
the power dissipation under normal
operating conditions is calculated as:
and turns Q2 on. With Q2 in conduction, the gate voltage of Q1 is held to
the clamping voltage of D3. The output
voltage equals the clamping voltage of
D3 minus the gate source voltage of
Q1. When overvoltage ceases, the
system resumes normal operation.
Component Selection. The components in the Figure 1 circuit remain
essentially the same for all input
voltage ranges. Only the main MOSFET
Q1 and the clamping diodes D1, D2 and
D3 are selected according to nominal
operating voltage and power.
The RIA12 standard prescribes an
input voltage variation of up to
1.5(VN) for one second. For converters
with an input voltage range that allows
the module to withstand this, the
breakdown voltage for D2 and D3 must
be greater than 1.5(VN) to prevent the
protection circuit from operating under
this condition, but less than the
converter’s high line voltage.
The diode D1 clamps high voltage
spikes that have low energy but
amplitudes that may exceed 1000V.
Therefore, D1 must be a TVS with a
clamping voltage higher than 3.5(VN)
to prevent damage by this transient.
(continued)
385V Surge
168V Surge
Module Input
Module Input
48V.
110V.
Gnd.
Gnd.
Figure 2—For a 48V input, a 20ms input transient with
output voltage clamped to the converter’s high line limit.
VICOR CORPORATION
Figure 3—For a 110V input, a 20ms input transient with
output voltage clamped to the converter’s high line limit.
• 25 Frontage Road • Andover, MA 01810 • TEL: 800-735-6200 • FAX: 978-475-6715 • 4/96
Application Note
Railway Standards
(page 3)
Test Results. This circuit has been
tested in the lab for 48V and 110V
inputs—the two most common in
railway applications—supplying a
150W DC-DC converter. The table
below lists the components used.
Converter
48VN
110VN
D1
1.5KE200A 1.5KE440A
D2
68V/0.5W 160V/0.5W
D3
68V/0.5W 160V/0.5W
Q1
IRFP250
IRFP450
Figures 2 and 3 show the 20ms input
transient and the output voltage
clamped to the converter’s high line
limit.
Physical Requirements
Operating temperature range.
Operating temperatures are divided
into four classes according to the
severity of the environment, as shown
in Table 2. When designing the power
supply, it is necessary to consider
overtemperature during start-up,
indicated in the third column.
In some railway applications, the
equipment is bulkhead mounted on the
wagon walls. This setup can take
advantage of the Vicor converters’
planar baseplate and use the cabinet as
a large heat sink.
Operating
Temp.
Classes
T1
T2
T3
TX
Vibration and Shock. EN50155
specifies that electronic equipment
mounted on boards and boxes fixed to
the vehicle frame must be able to
withstand vibration on all three axes at
the levels below:
• Frequency range: 5–150Hz
• Cross-over frequency: 8.2Hz
• Displacement amplitude (below
cross-over frequency): 7.5mm
• Acceleration amplitude (above crossover frequency): 20m/s2
The equipment also must be able to
withstand a 50ms, semi-sinusoidal
shock of 50m/s2 amplitude.
Because they are fully encapsulated in
epoxy resin, Vicor modules can easily
sustain these mechanical stresses.
However, close attention must be paid
to the PCB design and wiring to
prevent relative movements that can
stress the modules’ pins.
• • •
The Vicor Applications Manual
contains complete information about
how to use Vicor component power
products.
To address application conditions
outside the range of standard Vicor
DC-DC converters, contact Vicor
Applications Engineering for
alternative solutions.
Table 2 — Operating Temperature Ranges
Internal
Internal
Cubicle
Air Temp.
Cubicle
Overtemp.
Around
Temp.
(10 min.)
PCB
-25/+55ºC
+15ºC
-25/+70ºC
-40/+55ºC
+15ºC
-40/+70ºC
-25/+70ºC
+15ºC
-25/+85ºC
-40/+70ºC
+15ºC
-40/+85ºC