PDF Solder Mounting Design Information

3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
SAFETY CONSIDERATIONS
Fusing. Safety agency conditions of acceptability require
that the module positive (+) Input terminal be fused and
the baseplate of the converter be connected to earth
ground. The following table lists the acceptable fuse types
and current rating for the Maxi, Mini, Micro Family of
DC-DC converters. Safety Certifications on the Vicor web
site should always be consulted for the latest fusing
requirements.
Acceptable Fuse Types and Current Rating for the Maxi, Mini, Micro Family of Converters
Package Size
Input Voltage
Output Voltage
Output Power
Required Fuse
Maxi
Maxi
Maxi
Maxi
(A)
(A)
(A)
(A)
375
375
375
375
2
3.3
5, 8
12, 15, 24, 28, 32, 36, 48, 54
160
264 / 200
400 / 300
600 / 400
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
5A
5A
5A
5A
Mini
Mini
Mini
Mini
(B)
(B)
(B)
(B)
375
375
375
375
2
3.3
5, 8
12, 15, 24, 28, 36, 48
100
150 / 100
200 / 150
300 / 200
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
5A
5A
5A
5A
Micro
Micro
Micro
Micro
(C)
(C)
(C)
(C)
375
375
375
375
2
3.3
5, 8
12, 15, 24, 28, 36, 48
50
75 / 50
100 / 50
150 / 75
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
3A
3A
3A
3A
Maxi
Maxi
Maxi
Maxi
(A)
(A)
(A)
(A)
300
300
300
300
2
3.3
5, 8
12, 15, 24, 28, 36, 48
160
264 / 200
400 / 300
500 / 400
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
5A
5A
5A
5A
Mini
Mini
Mini
Mini
(B)
(B)
(B)
(B)
300
300
300
300
2
3.3
5, 8
12, 15, 24, 28, 36, 48
100
150 / 100
200 / 150
250 / 150
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
5A
5A
5A
5A
Micro
Micro
Micro
Micro
(C)
(C)
(C)
(C)
300
300
300
300
2
3.3
5, 8
12, 15, 24, 28, 36, 48
50
75 / 50
100 / 50
150 / 75
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron
PC-Tron
PC-Tron
PC-Tron
3A
3A
3A
3A
Maxi (A)
Maxi (A)
Maxi (A)
150
150
150
3.3
5, 8
12, 15, 24, 28, 36, 48
264 / 200
400 / 300
500 / 400
Bussmann ABC-8
Bussmann ABC-8
Bussmann ABC-8
Mini (B)
Mini (B)
Mini (B)
150
150
150
3.3
5, 8
12, 15, 24, 28, 36, 48
150 / 100
200 / 150
250 / 150
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Micro (C)
Micro (C)
Micro (C)
150
150
150
3.3
5, 8
12, 15, 24, 28, 36, 48
75
100
150
Bussmann PC-Tron 3A
Bussmann PC-Tron 3A
Bussmann PC-Tron 3A
Maxi (A)
Maxi (A)
Maxi (A)
110
110
110
3.3
5, 8
12, 15, 24, 28, 36, 48
200 / 150
300 / 200
400 / 300
Bussmann ABC-8
Bussmann ABC-8
Bussmann ABC-8
Mini (B)
Mini (B)
Mini (B)
110
110
110
3.3
5, 8
12, 15, 24, 28, 36, 48
100 / 75
150 / 100
200 / 150
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Micro (C)
Micro (C)
Micro (C)
110
110
110
3.3
5, 8
12, 15, 24, 28, 36, 48
50
75
100
Bussmann PC-Tron 3A
Bussmann PC-Tron 3A
Bussmann PC-Tron 3A
Maxi, Mini, Micro Design Guide
Page 12 of 88
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200
3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
Acceptable Fuse Types and Current Rating for the Maxi, Mini, Micro Family of Converters
Package Size
Input Voltage
Output Voltage
Output Power
Maxi (A)
Maxi (A)
Maxi (A)
72
72
72
3.3
5, 8
12, 15, 24, 28, 36, 48
264
300
400
Bussmann ABC-12
Bussmann ABC-12
Bussmann ABC-12
Mini (B)
Mini (B)
Mini (B)
72
72
72
3.3
5, 8
12, 15, 24, 28, 36, 48
100
150
250
Bussmann ABC-8
Bussmann ABC-8
Bussmann ABC-8
Micro (C)
Micro (C)
Micro (C)
72
72
72
3.3
5, 8
12, 15, 24, 28, 36, 48
75
100
150
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Bussmann PC-Tron 5A
Maxi (A)
Maxi (A)
Maxi (A)
48
48
48
3.3
5, 8
12, 15, 24, 28, 36, 48
264
400
500
Bussmann ABC-10
Bussmann ABC-15
Bussmann ABC-20
Mini
Mini
Mini
Mini
(B)
(B)
(B)
(B)
48
48
48
48
2
3.3
5, 8
12, 15, 24, 28, 36, 48
100
150
200
250
Bussmann
Bussmann
Bussmann
Bussmann
ABC-8
ABC-8
ABC-10
ABC-10
Micro
Micro
Micro
Micro
(C)
(C)
(C)
(C)
48
48
48
48
2
3.3
5, 8
12, 15, 24, 28, 36, 48
50
75 / 50
100 / 75 / 50
150 / 75
Bussmann
Bussmann
Bussmann
Bussmann
PC-Tron 5A
PC-Tron 5A
ABC-8
ABC-8
Maxi (A)
Maxi (A)
Maxi (A)
28
28
28
3.3
5
6.5, 8, 12, 15, 24, 28, 36, 48
150
175
200
Bussmann ABC-25
Bussmann ABC-25
Bussmann ABC-30
Mini (B)
Mini (B)
Mini (B)
28
28
28
3.3
5
12, 15, 24, 28, 36, 48
75
75
150
Bussmann ABC-15
Bussmann ABC-15
Bussmann ABC-15
Micro (C)
Micro (C)
Micro (C)
28
28
28
3.3
5
12, 15, 24, 28, 36, 48
50
50
100
Bussmann ABC- 8
Bussmann ABC-10
Bussmann ABC-10
Maxi (A)
Maxi (A)
24
24
3.3
5, 8, 12, 15, 24, 28, 36, 48
264 / 200
400 / 300
Bussmann ABC-25
Bussmann ABC-30
Mini (B)
Mini (B)
24
24
3.3
5, 8, 12, 15, 24, 28, 36, 48
150 / 100
200 / 150
Bussmann ABC-15
Bussmann ABC-15
Micro (C)
Micro (C)
24
24
3.3
5, 8, 12, 15, 24, 28, 36, 48
75 / 50
100 / 50
Bussmann ABC-8
Bussmann ABC-10
Maxi, Mini, Micro Design Guide
Page 13 of 88
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200
Required Fuse
3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
The fuse must be in series with the positive (+) Input lead.
Fusing the negative (–) Input lead does not provide adequate
protection since the PR and PC terminals of the converter
are referenced to the –Input. If a fuse located in the
–Input lead were to open, the PR and PC terminals could
rise to the potential of the +Input. This may damage any
converter or circuitry connected to these pins. The fuse
should not be located in an area with a high ambient
temperature as this will lower the current rating of the fuse.
THERMAL AND VOLTAGE HAZARDS
Vicor component power products are intended to be used
within protective enclosures. Vicor DC-DC converters work
effectively at baseplate temperatures, which could be
harmful if contacted directly. Voltages and high currents
(energy hazard) present at the terminals and circuitry
connected to them may pose a safety hazard if contacted
or if stray current paths develop. Systems with removable
circuit cards or covers which may expose the converter(s)
or circuitry connected to the converters, should have proper
guarding to avoid hazardous conditions.
The module pins are intended for PCB mounting either by
wave soldering to a PCB or by insertion into one of the
recommended PCB socket solutions. Use of discrete wire
soldered directly to the pins may cause intermittent or
permanent damage to the module; therefore, it is not recommended as a reliable interconnection scheme for production as a final released product. In addition, modules
that have been soldered into printed circuit boards and
have subsequently been removed should not be reused.
PC PIN
The PC pin should be used only to; disable the module,
provide a bias to input referenced circuitry or communicate
status of the module. The PC pin is referenced to the –Input
pin. All circuits that connect to the PC pin must use the
–Input as the reference. Do not break the connection
between the –Input and the circuitry connected to the
PC pin or damage to the module will result. Additional
requirements include:
•
Circuits that derive their power from the PC pin must
not exceed 1.5 mA.
•
Do not drive the PC pin with external circuitry.
•
Do not attempt to control the output of the converter
by PWM pulsing of the PC pin, or exceed a repetitive
on / off rate of 1 Hz.
For applications where the converter will be disabled on a
regular basis or where capacitance is added to this pin,
please contact Vicor Applications Engineering.
Maxi, Mini, Micro Design Guide
Page 14 of 88
HIGH-POWER ARRAYS AND PR PIN
To simplify the implementation of large arrays, a subset of
modules within the parallel array should be configured as
boosters (listeners) by connecting the SC pin to the –S pin.
Modules, which are configured as boosters, cannot assume
the role of drivers (talkers) for N+M redundant arrays.
Modules configured as boosters may be locally sensed.
Each module within the parallel array must be properly
bypassed with capacitors. Film or ceramic types should be
used across the input of the module and between each
input lead and the baseplate. Modules having input
sources, which are not connected to SELV sources, should
use X-capacitors across the input and Y-capacitors from
each input power pin to the baseplate. When in doubt
about capacitor safety approvals, always consult with the
governing safety regulatory agency or Vicor Applications
Engineering.
A maximum of 12 modules may be directly connected in
parallel. Please contact Vicor Applications Engineering for
assistance with larger arrays.
The PR pin is referenced to the –In pin; therefore, all
modules within the array must have a common lowimpedance connection between each –In pin. Special
precautions are necessary if a PCB is not used for interconnection of modules, because the wiring impedance
can be significant. Do not allow the connection between
the –In pin and the –In bus to become disconnected as
damage to the module will result.
Coupling transformers should be used to transmit the PR
pulse if long distances between each module are anticipated or if the interconnection impedance of the –In leads
is high or questionable. PR coupling transformer(s) should
be used if the PR pulse exits the PCB. For example, an
array constructed of multiple circuit cards plugged into a
backplane with a number of converters on each card
should have a PR coupling transformer at the entry point
of each card; however, no coupling transformer would be
required between each converter on the card of three or
less converters on a single PCB. Do not externally drive the
PR pin, connection to this pin is limited to Vicor module
application only.
INPUT SOURCE IMPEDANCE
The impedance of the source feeding the input of the
module directly affects both the stability and transient
response of the module. In general, the source impedance
should be lower than the input impedance of the module
by a factor of ten, from DC to 50 kHz.
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200
3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
To calculate the required source impedance, use the
following formula:
Z = 0.1(VLL)2 / Pin
where: Z is required input impedance
VLL is the low line input voltage
Pin is the input power of the module
Filters, which precede the module, should be well damped
to prevent ringing when the input voltage is applied or
the load on the output of the module is abruptly changed.
INPUT TRANSIENTS AND SURGES
The voltage applied to the input of the module must not
exceed the ratings outlined in the data sheet. Protection
devices such as Zener diodes and MOVs should be used
to protect the module from short-duration transients.
These shunt protection devices are effective only if the
source impedance is high relative to the impedance of
the protection device when it is conducting. For voltage
surges where the abnormal voltage is present for a long
period of time, shunt protection devices can easily be
damaged by the power dissipated. For this type of
condition, a voltage limiter in series with the input of
the module may be the best solution. Vicor Applications
Engineering can assist in recommending the appropriate
type of protection for the module.
NOTE: Do not allow the rate of change of the
input voltage to exceed 10 V/µs for any input
voltage deviation.
SENSE LEADS (Mini and Maxi only)
The sense leads of the module must always terminate
either directly to the output pins (local sense) or at the
load (remote sense). When remote sense is used, the
output wiring impedance in combination with the load
impedance can cause significant loss of phase margin and
result in oscillation and possible damage to the module,
poor transient response, or activation of the output
overvoltage protection. Long sense leads may require a
compensation circuit for stability.
Protection circuitry is required if the possibility of reversed
sense leads can occur. Please contact Vicor Applications
Engineering for specific recommendations.
Do not exceed 1 V between –S and –Out leads. This is
an important consideration if the converter is used in a
Hot-Swap application. ORing diodes, if used, should be
located in the +Output lead to avoid exceeding this rating.
OUTPUT CONNECTIONS
For systems designed to charge batteries, subject the
module output to dynamic loading, or loads that have
large reactive components, please contact Vicor
Applications Engineering to discuss your application
in detail.
Do not externally drive the output of the module 10%
above its nominal setpoint voltage.
Modules, that are used to charge batteries should be
applied with a diode in series with the output of the
module. The charge current must be externally controlled
to ensure that the module is not operated in excess of its
power or current rating.
Current-carrying conductors should be sized to minimize
voltage drops.
Do not use output ORing diodes with parallel arrays of
the Micro Family converters.
Output Overvoltage Protection (OVP). The OVP detection
circuitry within the converter is highly resistant to false
tripping. For the converter to shut down due to an OVP
condition two conditions must be satisfied (logical AND);
1. The voltage at the output terminals must be greater
than the OVP set point.
2. The secondary control IC within the converter must be
requesting a power conversion cycle from the internal
primary control IC.
By using this logic, false tripping of individual converters
due to externally induced OVP conditions such as load
dumps or, being driven by external voltage sources at the
output terminals is minimized. The user should not test
the OVP circuit by back driving the output terminals or by
any other means as the OVP circuitry is fully tested as part
of the inline manufacturing process.
OVERCURRENT PROTECTION
The Maxi, Mini, Micro converters incorporate a straightline type current limit. (Figure 3–1) As output current is
increased beyond Imax, the output voltage remains
constant and within its specified limits up to a point, IKNEE,
which is typically 5 – 25% greater than rated current,
Imax. Beyond IKNEE, the output voltage falls to Ishortcircuit.
Typically, modules will automatically recover after the overcurrent condition is removed.
Do not exceed the rated power of the converter. The total
of the power consumed by the load plus the power lost in
conductors from the converter to the load must be less
than the output power rating of the converter.
Maxi, Mini, Micro Design Guide
Page 15 of 88
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200
3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
ABSOLUTE MAXIMUM RATINGS
IMAX
Vout
Please consult the latest module data sheets available on
the Vicor website for maximum ratings concerning pin-topin voltages, isolation, temperature, and mechanical ratings.
IKNEE
GROUNDING OF BASEPLATE AND REFERENCING
OF INPUT AND OUTPUT TERMINALS
ISHORT CIRCUIT
Iout
Figure 3–1 — Typical Maxi, Mini, Micro current limiting
MAXIMUM OUTPUT CAPACITANCE
In general, adding external capacitance to the Maxi, Mini,
and Micro’s output is not required. However, it is often
common practice with power supply designs to add external
capacitance to the converter output for attenuation of
output ripple and / or improving dynamic load performance.
The Maxi, Mini, Micro converters typically have a faster
response to dynamic loads than other power solutions;
hence, external capacitors may not be necessary. In addition,
the output ripple and noise specification listed on the data
sheet may be acceptable for many applications.
A general equation for determining the maximum recommended output capacitance is as follows:
C(farad) =
Pout
Vout
The baseplate of the converter should always be connected
to earth ground. If for any reason this is not possible in
your application please consult with Vicor Applications
Engineering for acceptable alternatives for your application.
The input and output leads of the converter should be
referenced to the baseplate at some point to avoid stray
voltages. For offline applications the input leads are often
referenced to earth ground at the AC source ahead of the
bridge rectifier. Either + or –Output terminal may be
referenced to earth ground and the baseplate. “Floating”
inputs or outputs should at a minimum have a highresistance divider to bleed off stray charges to avoid
damage to the insulation system.
HIGH FREQUENCY BYPASSING
All Vicor converters must be bypassed for proper operation.
(Figure 3–2) The minimum complement of high-frequency
bypass capacitors must consist of the following:
•
0.2 µF ceramic or film type connected between
+In and –In.
•
4.7 nF Y-capacitor between +In and baseplate
and –In and baseplate.
•
10 nF ceramic or film capacitor between +Out and
baseplate and –Out and baseplate.
(400x10-6)
Vout
where: Pout is the output power of the converter
Vout is the nominal output voltage of the converter
The capacitance value is not the absolute maximum value,
but the value for which general application of the converter
can be deemed appropriate. Testing will be required to
ensure that the module is stable if this value is exceeded.
Approximately 10X the value calculated will cause the
converter to go into current limit at turn-on.
CAUTION: If exceeding this value, it is recommended
that Vicor Applications Engineering be consulted.
Maxi, Mini, Micro Design Guide
Page 16 of 88
All applications utilizing Maxi, Mini, Micro converters
should be properly bypassed, even if no EMC standards
need to be met. Bypass Vin and Vout pins to each module
baseplate as shown in Figure 3–2. Lead length should
be as short as possible. Recommended values vary
depending on the front end, if any, that is used with the
modules, and are indicated on the appropriate data sheet
or application note. In most applications, C1 is a 4,700 pF
Y-capacitor (Vicor P/N 01000) carrying the appropriate
safety agency approval; C2 is a 4,700 pF Y-capacitor (Vicor
P/N 01000) or a 0.01 µF ceramic capacitor rated at 500 V.
In PC board applications, each of these components is
typically small enough to fit under the module baseplate
flange. For PCB mounting of the module. Please refer to
Figures 3–3 and 3–4.
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200
3. Design Requirements
Design Guide & Applications Manual
For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies
C1a
Standoffs also provide necessary
mechanical support in order to
prevent mechanical stresses from
damaging the module during shock / vibration.
C2a
+IN
+OUT
Maxi, Mini, Micro
DC-DC Converter
CIN
–IN
–OUT
C1b
C2b
Standoff sitting on pad / plated through-hole
that is connected to the chassis
ground plane within the PCB.
Baseplate grounded
Figure 3–2 — Minimum recommended bypassing for Maxi, Mini,
and Micro; Keep all leads short.
Female-female standoffs are
shown, however standoffs are
also available in male-female versions.
Figure 3–3 — Recommended mounting method using standoffs
Onboard Mount
Inboard Mount
Cross-sectional view of pins
and mounting hardware
Cross-sectional view of pins
and mounting hardware.
0.53’’
13,5mm
0.46 ’’
11,7 mm
Exploded View
Exploded View
Chassis
P/N 20265 Ther mMate
Tapped #4–40
screw hole
P/N 20265 Ther mMate
Ex. V300C12M75BL
(Long Solder Pin,
Slotted Baseplate)
Ex. V300C12M75B
(Shor t Solder Pin,
Slotted Baseplate)
P/N 18157 Standoff Kit
P/N 18151 Standoff Kit
PCB thickness is
0.062" (1.5mm)
Pad and plated throughhole connected to
chassis ground plane
Pad and plated throughhole connected to
chassis ground plane
0.062" (1.5mm) PCB with
aperture to allow belly of
the module to recess into board
Figure 3–4 — Onboard vs. inboard mounting of (1/4 brick) Micro with slotted baseplate
Maxi, Mini, Micro Design Guide
Page 17 of 88
Tapped #4–40
screw hole
Rev 4.9
Apps. Eng. 800 927.9474
vicorpower.com
800 735.6200