3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies SAFETY CONSIDERATIONS Fusing. Safety agency conditions of acceptability require that the module positive (+) Input terminal be fused and the baseplate of the converter be connected to earth ground. The following table lists the acceptable fuse types and current rating for the Maxi, Mini, Micro Family of DC-DC converters. Safety Certifications on the Vicor web site should always be consulted for the latest fusing requirements. Acceptable Fuse Types and Current Rating for the Maxi, Mini, Micro Family of Converters Package Size Input Voltage Output Voltage Output Power Required Fuse Maxi Maxi Maxi Maxi (A) (A) (A) (A) 375 375 375 375 2 3.3 5, 8 12, 15, 24, 28, 32, 36, 48, 54 160 264 / 200 400 / 300 600 / 400 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 5A 5A 5A 5A Mini Mini Mini Mini (B) (B) (B) (B) 375 375 375 375 2 3.3 5, 8 12, 15, 24, 28, 36, 48 100 150 / 100 200 / 150 300 / 200 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 5A 5A 5A 5A Micro Micro Micro Micro (C) (C) (C) (C) 375 375 375 375 2 3.3 5, 8 12, 15, 24, 28, 36, 48 50 75 / 50 100 / 50 150 / 75 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 3A 3A 3A 3A Maxi Maxi Maxi Maxi (A) (A) (A) (A) 300 300 300 300 2 3.3 5, 8 12, 15, 24, 28, 36, 48 160 264 / 200 400 / 300 500 / 400 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 5A 5A 5A 5A Mini Mini Mini Mini (B) (B) (B) (B) 300 300 300 300 2 3.3 5, 8 12, 15, 24, 28, 36, 48 100 150 / 100 200 / 150 250 / 150 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 5A 5A 5A 5A Micro Micro Micro Micro (C) (C) (C) (C) 300 300 300 300 2 3.3 5, 8 12, 15, 24, 28, 36, 48 50 75 / 50 100 / 50 150 / 75 Bussmann Bussmann Bussmann Bussmann PC-Tron PC-Tron PC-Tron PC-Tron 3A 3A 3A 3A Maxi (A) Maxi (A) Maxi (A) 150 150 150 3.3 5, 8 12, 15, 24, 28, 36, 48 264 / 200 400 / 300 500 / 400 Bussmann ABC-8 Bussmann ABC-8 Bussmann ABC-8 Mini (B) Mini (B) Mini (B) 150 150 150 3.3 5, 8 12, 15, 24, 28, 36, 48 150 / 100 200 / 150 250 / 150 Bussmann PC-Tron 5A Bussmann PC-Tron 5A Bussmann PC-Tron 5A Micro (C) Micro (C) Micro (C) 150 150 150 3.3 5, 8 12, 15, 24, 28, 36, 48 75 100 150 Bussmann PC-Tron 3A Bussmann PC-Tron 3A Bussmann PC-Tron 3A Maxi (A) Maxi (A) Maxi (A) 110 110 110 3.3 5, 8 12, 15, 24, 28, 36, 48 200 / 150 300 / 200 400 / 300 Bussmann ABC-8 Bussmann ABC-8 Bussmann ABC-8 Mini (B) Mini (B) Mini (B) 110 110 110 3.3 5, 8 12, 15, 24, 28, 36, 48 100 / 75 150 / 100 200 / 150 Bussmann PC-Tron 5A Bussmann PC-Tron 5A Bussmann PC-Tron 5A Micro (C) Micro (C) Micro (C) 110 110 110 3.3 5, 8 12, 15, 24, 28, 36, 48 50 75 100 Bussmann PC-Tron 3A Bussmann PC-Tron 3A Bussmann PC-Tron 3A Maxi, Mini, Micro Design Guide Page 12 of 88 Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200 3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies Acceptable Fuse Types and Current Rating for the Maxi, Mini, Micro Family of Converters Package Size Input Voltage Output Voltage Output Power Maxi (A) Maxi (A) Maxi (A) 72 72 72 3.3 5, 8 12, 15, 24, 28, 36, 48 264 300 400 Bussmann ABC-12 Bussmann ABC-12 Bussmann ABC-12 Mini (B) Mini (B) Mini (B) 72 72 72 3.3 5, 8 12, 15, 24, 28, 36, 48 100 150 250 Bussmann ABC-8 Bussmann ABC-8 Bussmann ABC-8 Micro (C) Micro (C) Micro (C) 72 72 72 3.3 5, 8 12, 15, 24, 28, 36, 48 75 100 150 Bussmann PC-Tron 5A Bussmann PC-Tron 5A Bussmann PC-Tron 5A Maxi (A) Maxi (A) Maxi (A) 48 48 48 3.3 5, 8 12, 15, 24, 28, 36, 48 264 400 500 Bussmann ABC-10 Bussmann ABC-15 Bussmann ABC-20 Mini Mini Mini Mini (B) (B) (B) (B) 48 48 48 48 2 3.3 5, 8 12, 15, 24, 28, 36, 48 100 150 200 250 Bussmann Bussmann Bussmann Bussmann ABC-8 ABC-8 ABC-10 ABC-10 Micro Micro Micro Micro (C) (C) (C) (C) 48 48 48 48 2 3.3 5, 8 12, 15, 24, 28, 36, 48 50 75 / 50 100 / 75 / 50 150 / 75 Bussmann Bussmann Bussmann Bussmann PC-Tron 5A PC-Tron 5A ABC-8 ABC-8 Maxi (A) Maxi (A) Maxi (A) 28 28 28 3.3 5 6.5, 8, 12, 15, 24, 28, 36, 48 150 175 200 Bussmann ABC-25 Bussmann ABC-25 Bussmann ABC-30 Mini (B) Mini (B) Mini (B) 28 28 28 3.3 5 12, 15, 24, 28, 36, 48 75 75 150 Bussmann ABC-15 Bussmann ABC-15 Bussmann ABC-15 Micro (C) Micro (C) Micro (C) 28 28 28 3.3 5 12, 15, 24, 28, 36, 48 50 50 100 Bussmann ABC- 8 Bussmann ABC-10 Bussmann ABC-10 Maxi (A) Maxi (A) 24 24 3.3 5, 8, 12, 15, 24, 28, 36, 48 264 / 200 400 / 300 Bussmann ABC-25 Bussmann ABC-30 Mini (B) Mini (B) 24 24 3.3 5, 8, 12, 15, 24, 28, 36, 48 150 / 100 200 / 150 Bussmann ABC-15 Bussmann ABC-15 Micro (C) Micro (C) 24 24 3.3 5, 8, 12, 15, 24, 28, 36, 48 75 / 50 100 / 50 Bussmann ABC-8 Bussmann ABC-10 Maxi, Mini, Micro Design Guide Page 13 of 88 Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200 Required Fuse 3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies The fuse must be in series with the positive (+) Input lead. Fusing the negative (–) Input lead does not provide adequate protection since the PR and PC terminals of the converter are referenced to the –Input. If a fuse located in the –Input lead were to open, the PR and PC terminals could rise to the potential of the +Input. This may damage any converter or circuitry connected to these pins. The fuse should not be located in an area with a high ambient temperature as this will lower the current rating of the fuse. THERMAL AND VOLTAGE HAZARDS Vicor component power products are intended to be used within protective enclosures. Vicor DC-DC converters work effectively at baseplate temperatures, which could be harmful if contacted directly. Voltages and high currents (energy hazard) present at the terminals and circuitry connected to them may pose a safety hazard if contacted or if stray current paths develop. Systems with removable circuit cards or covers which may expose the converter(s) or circuitry connected to the converters, should have proper guarding to avoid hazardous conditions. The module pins are intended for PCB mounting either by wave soldering to a PCB or by insertion into one of the recommended PCB socket solutions. Use of discrete wire soldered directly to the pins may cause intermittent or permanent damage to the module; therefore, it is not recommended as a reliable interconnection scheme for production as a final released product. In addition, modules that have been soldered into printed circuit boards and have subsequently been removed should not be reused. PC PIN The PC pin should be used only to; disable the module, provide a bias to input referenced circuitry or communicate status of the module. The PC pin is referenced to the –Input pin. All circuits that connect to the PC pin must use the –Input as the reference. Do not break the connection between the –Input and the circuitry connected to the PC pin or damage to the module will result. Additional requirements include: • Circuits that derive their power from the PC pin must not exceed 1.5 mA. • Do not drive the PC pin with external circuitry. • Do not attempt to control the output of the converter by PWM pulsing of the PC pin, or exceed a repetitive on / off rate of 1 Hz. For applications where the converter will be disabled on a regular basis or where capacitance is added to this pin, please contact Vicor Applications Engineering. Maxi, Mini, Micro Design Guide Page 14 of 88 HIGH-POWER ARRAYS AND PR PIN To simplify the implementation of large arrays, a subset of modules within the parallel array should be configured as boosters (listeners) by connecting the SC pin to the –S pin. Modules, which are configured as boosters, cannot assume the role of drivers (talkers) for N+M redundant arrays. Modules configured as boosters may be locally sensed. Each module within the parallel array must be properly bypassed with capacitors. Film or ceramic types should be used across the input of the module and between each input lead and the baseplate. Modules having input sources, which are not connected to SELV sources, should use X-capacitors across the input and Y-capacitors from each input power pin to the baseplate. When in doubt about capacitor safety approvals, always consult with the governing safety regulatory agency or Vicor Applications Engineering. A maximum of 12 modules may be directly connected in parallel. Please contact Vicor Applications Engineering for assistance with larger arrays. The PR pin is referenced to the –In pin; therefore, all modules within the array must have a common lowimpedance connection between each –In pin. Special precautions are necessary if a PCB is not used for interconnection of modules, because the wiring impedance can be significant. Do not allow the connection between the –In pin and the –In bus to become disconnected as damage to the module will result. Coupling transformers should be used to transmit the PR pulse if long distances between each module are anticipated or if the interconnection impedance of the –In leads is high or questionable. PR coupling transformer(s) should be used if the PR pulse exits the PCB. For example, an array constructed of multiple circuit cards plugged into a backplane with a number of converters on each card should have a PR coupling transformer at the entry point of each card; however, no coupling transformer would be required between each converter on the card of three or less converters on a single PCB. Do not externally drive the PR pin, connection to this pin is limited to Vicor module application only. INPUT SOURCE IMPEDANCE The impedance of the source feeding the input of the module directly affects both the stability and transient response of the module. In general, the source impedance should be lower than the input impedance of the module by a factor of ten, from DC to 50 kHz. Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200 3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies To calculate the required source impedance, use the following formula: Z = 0.1(VLL)2 / Pin where: Z is required input impedance VLL is the low line input voltage Pin is the input power of the module Filters, which precede the module, should be well damped to prevent ringing when the input voltage is applied or the load on the output of the module is abruptly changed. INPUT TRANSIENTS AND SURGES The voltage applied to the input of the module must not exceed the ratings outlined in the data sheet. Protection devices such as Zener diodes and MOVs should be used to protect the module from short-duration transients. These shunt protection devices are effective only if the source impedance is high relative to the impedance of the protection device when it is conducting. For voltage surges where the abnormal voltage is present for a long period of time, shunt protection devices can easily be damaged by the power dissipated. For this type of condition, a voltage limiter in series with the input of the module may be the best solution. Vicor Applications Engineering can assist in recommending the appropriate type of protection for the module. NOTE: Do not allow the rate of change of the input voltage to exceed 10 V/µs for any input voltage deviation. SENSE LEADS (Mini and Maxi only) The sense leads of the module must always terminate either directly to the output pins (local sense) or at the load (remote sense). When remote sense is used, the output wiring impedance in combination with the load impedance can cause significant loss of phase margin and result in oscillation and possible damage to the module, poor transient response, or activation of the output overvoltage protection. Long sense leads may require a compensation circuit for stability. Protection circuitry is required if the possibility of reversed sense leads can occur. Please contact Vicor Applications Engineering for specific recommendations. Do not exceed 1 V between –S and –Out leads. This is an important consideration if the converter is used in a Hot-Swap application. ORing diodes, if used, should be located in the +Output lead to avoid exceeding this rating. OUTPUT CONNECTIONS For systems designed to charge batteries, subject the module output to dynamic loading, or loads that have large reactive components, please contact Vicor Applications Engineering to discuss your application in detail. Do not externally drive the output of the module 10% above its nominal setpoint voltage. Modules, that are used to charge batteries should be applied with a diode in series with the output of the module. The charge current must be externally controlled to ensure that the module is not operated in excess of its power or current rating. Current-carrying conductors should be sized to minimize voltage drops. Do not use output ORing diodes with parallel arrays of the Micro Family converters. Output Overvoltage Protection (OVP). The OVP detection circuitry within the converter is highly resistant to false tripping. For the converter to shut down due to an OVP condition two conditions must be satisfied (logical AND); 1. The voltage at the output terminals must be greater than the OVP set point. 2. The secondary control IC within the converter must be requesting a power conversion cycle from the internal primary control IC. By using this logic, false tripping of individual converters due to externally induced OVP conditions such as load dumps or, being driven by external voltage sources at the output terminals is minimized. The user should not test the OVP circuit by back driving the output terminals or by any other means as the OVP circuitry is fully tested as part of the inline manufacturing process. OVERCURRENT PROTECTION The Maxi, Mini, Micro converters incorporate a straightline type current limit. (Figure 3–1) As output current is increased beyond Imax, the output voltage remains constant and within its specified limits up to a point, IKNEE, which is typically 5 – 25% greater than rated current, Imax. Beyond IKNEE, the output voltage falls to Ishortcircuit. Typically, modules will automatically recover after the overcurrent condition is removed. Do not exceed the rated power of the converter. The total of the power consumed by the load plus the power lost in conductors from the converter to the load must be less than the output power rating of the converter. Maxi, Mini, Micro Design Guide Page 15 of 88 Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200 3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies ABSOLUTE MAXIMUM RATINGS IMAX Vout Please consult the latest module data sheets available on the Vicor website for maximum ratings concerning pin-topin voltages, isolation, temperature, and mechanical ratings. IKNEE GROUNDING OF BASEPLATE AND REFERENCING OF INPUT AND OUTPUT TERMINALS ISHORT CIRCUIT Iout Figure 3–1 — Typical Maxi, Mini, Micro current limiting MAXIMUM OUTPUT CAPACITANCE In general, adding external capacitance to the Maxi, Mini, and Micro’s output is not required. However, it is often common practice with power supply designs to add external capacitance to the converter output for attenuation of output ripple and / or improving dynamic load performance. The Maxi, Mini, Micro converters typically have a faster response to dynamic loads than other power solutions; hence, external capacitors may not be necessary. In addition, the output ripple and noise specification listed on the data sheet may be acceptable for many applications. A general equation for determining the maximum recommended output capacitance is as follows: C(farad) = Pout Vout The baseplate of the converter should always be connected to earth ground. If for any reason this is not possible in your application please consult with Vicor Applications Engineering for acceptable alternatives for your application. The input and output leads of the converter should be referenced to the baseplate at some point to avoid stray voltages. For offline applications the input leads are often referenced to earth ground at the AC source ahead of the bridge rectifier. Either + or –Output terminal may be referenced to earth ground and the baseplate. “Floating” inputs or outputs should at a minimum have a highresistance divider to bleed off stray charges to avoid damage to the insulation system. HIGH FREQUENCY BYPASSING All Vicor converters must be bypassed for proper operation. (Figure 3–2) The minimum complement of high-frequency bypass capacitors must consist of the following: • 0.2 µF ceramic or film type connected between +In and –In. • 4.7 nF Y-capacitor between +In and baseplate and –In and baseplate. • 10 nF ceramic or film capacitor between +Out and baseplate and –Out and baseplate. (400x10-6) Vout where: Pout is the output power of the converter Vout is the nominal output voltage of the converter The capacitance value is not the absolute maximum value, but the value for which general application of the converter can be deemed appropriate. Testing will be required to ensure that the module is stable if this value is exceeded. Approximately 10X the value calculated will cause the converter to go into current limit at turn-on. CAUTION: If exceeding this value, it is recommended that Vicor Applications Engineering be consulted. Maxi, Mini, Micro Design Guide Page 16 of 88 All applications utilizing Maxi, Mini, Micro converters should be properly bypassed, even if no EMC standards need to be met. Bypass Vin and Vout pins to each module baseplate as shown in Figure 3–2. Lead length should be as short as possible. Recommended values vary depending on the front end, if any, that is used with the modules, and are indicated on the appropriate data sheet or application note. In most applications, C1 is a 4,700 pF Y-capacitor (Vicor P/N 01000) carrying the appropriate safety agency approval; C2 is a 4,700 pF Y-capacitor (Vicor P/N 01000) or a 0.01 µF ceramic capacitor rated at 500 V. In PC board applications, each of these components is typically small enough to fit under the module baseplate flange. For PCB mounting of the module. Please refer to Figures 3–3 and 3–4. Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200 3. Design Requirements Design Guide & Applications Manual For Maxi, Mini, Micro Family DC-DC Converters and Configurable Power Supplies C1a Standoffs also provide necessary mechanical support in order to prevent mechanical stresses from damaging the module during shock / vibration. C2a +IN +OUT Maxi, Mini, Micro DC-DC Converter CIN –IN –OUT C1b C2b Standoff sitting on pad / plated through-hole that is connected to the chassis ground plane within the PCB. Baseplate grounded Figure 3–2 — Minimum recommended bypassing for Maxi, Mini, and Micro; Keep all leads short. Female-female standoffs are shown, however standoffs are also available in male-female versions. Figure 3–3 — Recommended mounting method using standoffs Onboard Mount Inboard Mount Cross-sectional view of pins and mounting hardware Cross-sectional view of pins and mounting hardware. 0.53’’ 13,5mm 0.46 ’’ 11,7 mm Exploded View Exploded View Chassis P/N 20265 Ther mMate Tapped #4–40 screw hole P/N 20265 Ther mMate Ex. V300C12M75BL (Long Solder Pin, Slotted Baseplate) Ex. V300C12M75B (Shor t Solder Pin, Slotted Baseplate) P/N 18157 Standoff Kit P/N 18151 Standoff Kit PCB thickness is 0.062" (1.5mm) Pad and plated throughhole connected to chassis ground plane Pad and plated throughhole connected to chassis ground plane 0.062" (1.5mm) PCB with aperture to allow belly of the module to recess into board Figure 3–4 — Onboard vs. inboard mounting of (1/4 brick) Micro with slotted baseplate Maxi, Mini, Micro Design Guide Page 17 of 88 Tapped #4–40 screw hole Rev 4.9 Apps. Eng. 800 927.9474 vicorpower.com 800 735.6200