HRC6000 TAZ Series Datasheet

TAZ Series
HRC6000 Medical Implantable Grade
The TAZ HRC6000 Medical Grade series is the
next generation of our internally qualified
implantable medical grade tantalum capacitors.
These components are screened using our newly
designed Q-Process to effectively remove
components that may experience parametric
shifts through customer processing or display
instability through life testing.
Due to the deficiencies of Weibull grading and its
tendency to Burn-In potentially unstable units,
this Q-Process utilizes a Product Level
Designation system based on a simulated
production routine performed on a sample from
the population. Once that is completed a
calculation is done based on the performance of
the sample which can take into account the
application conditions of the end customer.
This system also allows for derating
recommendations to be relaxed as illustrated by
the section below.
These components are manufactured and tested
in the AVX Biddeford Maine facility which is ISO
13485 certified. For more information on this
process or to request a specific rating please
contact the factory. In addition, DC leakage
testing at application voltage is available upon
request.
CASE DIMENSIONS:
millimeters (inches)
Case
Code
Length (L)
±0.38
(0.015)
Width (W)
±0.38
(0.015)
Height (H)
±0.38
(0.015)
Term. Width (W1)
E
5.08
(0.200)
2.54
(0.100)
1.27
(0.050)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
Term. Length
(A)
+0.25/-0.13
(+0.010/-0.005)
0.76
(0.030)
S min
Typical
Weight
(g)
2.92
(0.115)
0.065
MARKING
(White marking on black body)
Polarity Stripe (+)
Capacitance Code
Rated Voltage
CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE
(LETTER DENOTES CASE SIZE)
μF
0.15
0.22
0.33
0.47
0.68
1
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
Capacitance
Code
154
224
334
474
684
105
155
225
335
475
685
106
156
226
336
476
686
6V
Rated Voltage
10V
15V
A*
A*
A*
E
E
Available ratings
*Codes under development - subject to change.
28
041416
TAZ Series
HRC6000 Medical Implantable Grade
HOW TO ORDER
TAZ E
Type
Case
Size
106
*
015
C
Capacitance Capacitance
Voltage
ESR
Packaging
Code
Tolerance
Code
C = Std ESR B = Bulk
pF code:
J = ±5%
006 = 6Vdc L = Low ESR R = 7" T&R
1st two digits
K = ±10% 010 = 10Vdc
W = Waffle
represent
M = ±20% 015 = 15Vdc
significant
figures 3rd
digit represents
multiplier
(number of
zeros to follow)
L
Inspection Level
L = Group A
Q
6
^
Reliability Grade Qualification Termination Finish
Level
Product Level
H = Solder Plated
6 = HRC6000 0 = Solder Fused
Designator:
Q = 0.1%/1000 hrs.
9 = Gold Plated
Minimum,
7 =100% Tin
60% conf
++
Surge Test
Option
00 = None
23 = 10 Cycles, +25ºC
24 = 10 Cycles,
-55ºC & +85ºC
45 = 10 Cycles,
-55ºC & +85ºC
before Weibull
LEAD-FREE COMPATIBLE
COMPONENT
For RoHS compliant products,
please select correct termination style.
*Contact factory for AVX HRC6000 Medical Grade SCD details.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage (VR)
Category Voltage (VC)
Temperature Range:
041416
Unless otherwise specified, all technical data relate to an ambient temperature of 25°C
0.68 μF to 33 μF
±5%; ±10%; ±20%
85°C:
6
10
15
125°C:
4
6.7
10
-55°C to +125°C
29
TAZ Series
HRC6000 Medical Implantable Grade
RATING & PART
NUMBER REFERENCE
AVX HRC6000 P/N
Case
TAZE156*010CLQ6^++
TAZE106*015CLQ6^++
E
E
Parametric Specifications by Rating
DCL max
DF max
Cap
DC Rated ESR
@ 120Hz Voltage @ 100kHz +25°C
μF
@ 25ºC
15
10
V
Ohms
@ +85ºC @ +25ºC
10
3
15
4
+25°C +(85/125)°C -55°C
+85°C
+125°C
(μA)
(μA)
(μA)
(%)
(%)
(%)
0.375
0.375
3.75
3.75
4.50
4.50
8
6
10
8
10
8
Typical RMS Ripple Data by Rating
25ºC
85ºC
125ºC
25ºC
85ºC
125ºC
Power
Ripple
Ripple
Ripple
Ripple
Ripple
Dissipation Ripple
Current Current Current Voltage Voltage
Voltage
A
A
A
V
V
V
W
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.090
0.173
0.156
0.069
0.520
0.468
0.208
0.090
0.150
0.135
0.060
0.600
0.540
0.240
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
HRC6000 DERATING GUIDELINES
Due to our new Q-Process technology the need for a typical
50% derating of the capacitors rated voltage in application is
no longer needed. Below is a table outlining some of the
common applications where these components are utilized
along with appropriate derating recommendations. When
determining the appropriate capacitor voltage rating to
utilize, the application voltage is determined by the maximum
D.C. voltage with the addition of any A.C. ripple voltage that
may be present.
30
Recommended Derating
20%
0%
0%
0%
Application
Filtering
Pacing
Hold-Up
Charging
041416