m6xtc.pdf

Double Balanced Mixer
Model M6xTC
RF Band
Electrical Specifications
RF 1.0 to 2.0 GHz
:
(1)
Conditions
Parameter
SSB Conversion loss:(2)
RF(GHz)
1.0-2.0
LO(GHz)
1.0-2.0
1.0-2.0
1.0-2.0
1.0-2.0
1.0-2.0
DC-1.0
Desensitization Point:
1.0-2.0
1.0-2.0
DC-1.0
Input Third Order
Intercept Point:
1.0-2.0
1.0-2.0
DC-1.0
LO Power:
1.0-2.0
1.0-2.0
DC-1.0
Isolation
LO to RF:
LO to IF:
Input 1 dB
Compression Point:
(3)
Specifications
IF(GHz)
DC-1.0
Min
30 dB
20 dB
Notes:
1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the
nominal LO power. Specifications indicated as typical are not guaranteed.
2. SSB Noise figure is nominally within ±0.5 dB of the SSB conversion loss for IF frequencies greater than 10 MHz.
3. Usable LO drives are up to 2 dB below and 3 dB above nominal.
M6xTC
Typical
8.0 dB
Max
9.0 dB
38 dB
25 dB
+3 dBm
+5 dBm
+15 dBm
+1 dBm
+3 dBm
+13 dBm
+13 dBm
+15 dBm
+26 dBm
+7 dBm
+13 dBm
+23 dBm
M63
M66
M67
M63
M66
M67
M63
M66
M67
M63
M66
M67
Model M6xTC
LO Power
3 = +7 dBm
6 = +13 dBm
7 = +23 dBm
Typical Performance at 25˚C
Outline: TC
All dimensions are in inches and [mm].
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532
www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001
Rev.
1/27/09