AORP

AORP
Over-range protectors
Main Features
„„
For corrosive gasses and
liquids
„„
Protection of instruments from
over pressure
„„
For pressure gauges, pressure
switches and transmitters
„„Option: NACE conform
Applications
„„Oil & Gas / Chemical
„„Water & Waste water
„„Energy
„„Machinery
Description
Technical data
These over-range protectors have been designed to protect pressure
gauges (or other instruments) against accidential overpressure.
The medium must be a clean gas or fluid without particles and with low
viscosity.
Working principle:
The applied pressure works against an adjustable internal spring by
means of a bellow or piston.
As soon as the pressure reaches the adjusted setpoint, an internal
valve closes and avoids further pressure increase on the outlet side.
When the pressure decreases, the valve will open 20 % below the
closing pressure.
Two models are available according to the ranges for the setpoint
adjustment (AORP-0, AORP-B, see ordering details on page 2).
Inlet: Outlet: Max. pressure: Max. temperature: Setpoint: Setpoint repeatability:
1/2 NPT female
1/2 NPT female
700 bar
150 °C
see ordering details on page 2
AORP-0: ± 10 %
AORP-B: ± 2 %
(when the pressure is increasing over ≥ 5 s)
20 %
Stainless steel 1.4404 (316L)
Viton
Stainless steel 1.4404 (316L)
Dead band: (1)
Valve: O-ring: Body, adjusting screw
and cleaning plug:
Piston (AORP-0): Stainless steel 1.4404 (316L)
Bellow (AORP-B): Stainless steel 1.4404 (316L)
Spring: 1.4310 (301)
Gasket of the cleaning plug: Aluminium
(1)
The valve opens 20 % below the adjusted setpoint for closing.
Code SETP
Compliant with NACE MR0175 and MR0103
Code 0073
Degreased for oxygen applications
Code 0765
Material certificate 3.1
Code Q003
2015-03-03
Customer specific set point adjustment
Design and specifications subject to change without notice
Options
www.baumer.com
Data sheet A51.01
Page 1 / 2
AORP
Over-range protectors
Dimensions (mm)
1/2 NPT
L
Weight in kg
AORP-0
90
0.500
AORP-B
117
0.600
1/2 NPT
L
Ordering details AORP
Type
High pressure (piston, ranges 3xx)
Low pressure (bellow, ranges 5xx)
Pressure range for setpoint adjustment (bar)
-1 ...
0
0.1 ...
0.4
0.4 ...
0.6
0.6 ...
1
1 ...
3
3 ...
6
6 ... 16
3 ...
6
6 ... 18
18 ... 25
25 ... 80
80 ... 160
160 ... 400
Options to be added behind the / (see example below)
AORP
–
xxx
/
–
0
B
507
501
502
503
504
505
506
381
382
383
384
385
386
/
Ordering example
AORP _
0385
/
0765
Over-range protector
Pressure range: 80 + 160 bar
2015-03-03
Option: Degreased for oxygen applications
Design and specifications subject to change without notice
AORP
Model
Over-range protector
www.baumer.com
Data sheet A51.01