SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
FEATURES
•
•
•
•
•
•
•
•
1.5 A current output
extremely high efficiency up to 97%
no heat sink required
pin compatible to LM78XX linear regulators
available in straight and right angle SIP packages
low ripple and noise
short circuit protection, thermal shutdown
wide temperature (-40~85°C)
input
voltage
MODEL
output
voltage
output
current
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
max
(mA)
max
(mVp-p)
Vin max
(%)
V7802-1500*
12
4.75~18
2.5
1,500
45
85
V7803-1500
12
4.75~18
3.3
1,500
45
88
V7805-1500
12
6.5~18
5
1,500
45
91
V7806-1500
12
8~18
6.5
1,500
45
93
Notes:
1. ripple and noise are measured at 20 MHz BW
*. Discontinued
PART NUMBER KEY
V78 XX - 1500 X
Base Number
Output Voltage
Output Current
cui.com
"blank" = straight pins
R = 90° pins
For more information, please visit the product page.
CUI Inc │ SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 03/21/2014 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
2.5 and 3.3 V outputs
5 V output
6.5 V output
4.75
6.5
8
12
12
12
18
18
18
Vdc
Vdc
Vdc
parameter
conditions/description
min
typ
max
units
line regulation
Vin = min ~ max, at full load
±0.5
±0.75
%
load regulation
measured from 10% load to full load
±0.5
±1.0
%
OUTPUT
voltage accuracy
100% load
switching frequency
100% load, input voltage range
300
temperature coefficient
±2
±3
%
340
380
kHz
±0.02
%/°C
PROTECTIONS
parameter
conditions/description
min
short circuit protection
continuous, automatic recovery
thermal shutdown
typ
max
150
units
°C
SAFETY AND COMPLIANCE
parameter
conditions/description
EMI/EMC
EN 55022 class B, EN 61000-4-2 class A
min
MTBF
RoHS
typ
max
2,000,000
units
hours
2011/65/EU
ENVIRONMENTAL
parameter
max
units
operating temperature
conditions/description
min
-40
typ
85
°C
storage temperature
-55
125
°C
100
°C
95
%
case temperature
storage humidity
non-condensing
temperature rise
at full load
lead temperature
1.5 mm from case for 10 seconds
25
cui.com
°C
300
°C
For more information, please visit the product page.
CUI Inc │ SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 03/21/2014 │ page 3 of 6
DERATING CURVES
1. output power vs. ambient temperature
Load (%)
100
80
60
40
20
-40
-20
0
20
40
60 71
85
100
120
Ambient Temperature (°C)
MECHANICAL
parameter
conditions/description
dimensions
0.689 x 0.354 x 0.453 (11.50 x 9.00 x 17.50 mm)
min
case material
plastic (UL94-V0)
typ
max
units
inch
weight
4.0
g
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
V78XX-1500
V78XX-1500R
9.00 [0.354]
17.50 [0.689]
9.00 [0.354]
0.50 [0.020]
11.50[0.453]
0.50 [0.020]
11.50[0.453]
17.50 [0.689]
4.10[0.161]
4.10 [0.161]
1.50
[0.059]
2.15
[0.085]
5.08[0.200]
5.08 [0.200]
1.00 [0.039]
(Bottom View)
1 2
3
0.30 [0.012]
0.50 [0.020]
1 2
3
2.54 [0.100]
2.15
[0.085]
2.15 [0.085]
(Bottom View)
1
2
5.08 [0.200]
5.08 [0.200]
1.35 [0.053]
1
3
2
3
2.54 [0.100]
1.00 [0.039]
PIN CONNECTIONS
PIN
FUNCTION
1
+Vin
2
GND
3
+Vo
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 03/21/2014 │ page 4 of 6
EXTERNAL CAPACITOR TABLE
Part Number
C1 (Ceramic capacitor)
C2 (Ceramic capacitor)
V7802-1500
10μF/25V
22μF/6.3V
V7803-1500
10μF/25V
22μF/6.3V
V7805-1500
10μF/25V
22μF/16V
V7806-1500
10μF/25V
22μF/16V
TYPICAL APPLICATION CIRCUIT
APPLICATION EXAMPLE
Positive Output
1 V78XX-1500(R) 3
+Vin
1
Vin
V78XX-1500(R)
3
C3
+Vout
+Vout
C4
2
GND
2
C1
GND
C1
C2
1
V78XX-1500(R)
3
GND
GND
2
C2
Negative Output
-Vout
GND
GND
C1
Note:
+Vin
1
V78XX-1500(R)
3
2
1. C1 and C2 are required and should be fitted close to the converter
pins.
2. The capacitance of C1and C2 sees external capacitor table, it can
be increased properly if required, and tantalum or low ESR
electrolytic capacitors may also suffice.
3. No parallel connection or plug and play.
C2
-Vout
INPUT FILTER CIRCUIT
1 0 u H-4 7 u H
Vin
Vin
Vo
Vout
GND
10uF
10uF
GND
GND
OUTPUT FILTER CIRCUIT
1 0 u H-4 7 u H
Vin
Vin
Vo
GND
10uF
10uF
GND
cui.com
22uF
RL
For more information, please visit the product page.
CUI Inc │ SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 03/21/2014 │ page 5 of 6
EMC RECOMMENDED CIRCUIT
1 mH
Vin
Vin
Vout
Vo
GND
2.2 uF
330 uF
1u F
GND
GND
1mH
TEST CONFIGURATION
Efficiency and Output Voltage Ripple Test
25. 4mm
25.4mm
12.7mm
D C /D C
C onverter
3
1 F
2
C1
+Vout
Copper strip
C2
10 F
Ceramic Tantalum
Scope
Load
1
2.54 mm
Vin
GND
Copper stri p
Start-up and Load Transient Response Test
D C /D C
C onverter
2
C1
+Vou t
Copper strip
3
Scope
C2
Load
1
2.54 mm
Vin
50.8 m m
GND
Copper strip
EFFICIENCY AND RIPPLE CURVES
Efficiency
Ripple
Efficiency VS. Input voltage
Ripple VS. Load(Vin=nominal)
37
32
R ipple(m V )
E ffic ie n c y ( % )
V7802-1500
V7803-1500
V7805-1500
V7806-1500
27
V7802-1500
22
17
V7803-1500
V7805-1500
V7806-1500
12
7
2
150 300 450 600 750 900 1050 1200 1350 1500
Input voltage(V)
Load(mA)
Ripple VS.Input voltage(full load)
Efficiency VS.Load(Vin=nominal)
90
V7802-1500
80
R ip p le ( m V )
E ffic ie n c y ( % )
100
V7803-1500
V7805-1500
70
V7806-1500
60
50
150 300 450 600 750 900 1050 1200 1350 1500
45
40
35
30
25
20
15
10
5
0
V7802-1500
V7803-1500
V7805-1500
V7806-1500
4.75 5
Load(mA)
6
6.5 7.2
8
9
10 12 15 18 20
Input voltage(V)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: V78-1500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR
date 03/21/2014 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
07/16/2010
1.01
V-Infinity branding removed
09/04/2012
1.02
updated typical application circuits
09/25/2012
discontinued model V7802-1500
03/21/2014
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.