Specifications Download

[ UTZ-SC0323_2 ]
2012/10/02
Aquamarine Laser Diode
NDA4116


Features
Outline Dimension
• Peak Wavelength: 473nm
• Optical Output Power: 100mW
• Can Type: 5.6 mm Floating Mounted with Photo Diode and Zener Diode
Unit (mm)
(
Item
Symbol
Absolute
Maximum Ratings
Unit
0
+ .03
0
6 5.
1.
6
)
Φ
Absolute Maximum Ratings
Φ
(90°)
Emitting Point
(0.4)
85
mA
PD Reverse Voltage
Vr (PD)
5
V
Storage Temperature
Tstg
-40 ~ 85
C
Operating Case Temperature
Tc
0 ~ 60
C
Z+
Φ 4.2±0.2
Φ 3.55±0.1
0.25±0.03
Ir (LD)
Initial Electrical/Optical Characteristics
Item
Condition
Symbol
Min
Typ.
Optical Output Power
CW
Po
-
-
Peak Wavelength
Po=100mW
p
468
473
Glass Thickness
Allowable Reverse Current
1.0±0.1
Emitting Point
Reference Plane
(1.3)
mW
0.4±0.1
120
1.2±0.1
2.3±0.2
Po
6.5±1.0
Optical Output Power
4×Φ 0.43±0.08
(Tc=25C)
Max Unit
100 mW
3
X+
478
nm
1
2
4
Threshold Current
CW
Ith
-
20
45
mA
Operating Current
Po=100mW
Iop
-
120
150
mA
Slope Efficiency
CW

0.8
1.0
-
W/A
Operating Voltage
Po=100mW
Vop
5.0
5.7
6.5
V
Parallel
Beam
Po=100mW
Divergence* Perpendicular
//
8.0
9.5
12.0
°

20.0
23.5
27.0
°
//
-2.5
-
2.5
°

-3.0
-
3.0
°
Im
0.2
1.0
2.0
mA
Parallel
Beam Pointing
Po=100mW
Accuracy
Perpendicular
Monitor Current**
Po=100mW
* Full angle at 50% from peak intensity
** Monitor Current is short time power reference purpose only. Not guaranteed for
accuracy.
Φ 2.0±0.2
Y+(
) are reference figures
Pin Connection
This model has a Zener Diode built in
as a protection circuit against static
electricity.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
NICHIA CORPORATION
http://www.nichia.co.jp
 HEADQUARTERS
491 Oka, Kaminaka-Cho, Anan-Shi, TOKUSHIMA 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
 CONTACT
TOKYO SALES OFFICE
13F Tamachi Center Building 34-7, Shiba 5-Chome, Minato-Ku, TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ UTZ-SC0323_2 ]
2012/10/02

Typical Characteristics
 Optical Output Power vs. Forward Current
 Forward Voltage vs. Forward Current
7
Tc=0℃
Tc=20℃
Tc=40℃
Tc=60℃
100
80
6
Forward Voltage Vf [V]
Optical Output Power P o [mW]
120
60
40
20
5
4
3
Tc=0℃
Tc=20℃
Tc=40℃
Tc=60℃
2
1
0
0
0
30
60
90
120
150
0
30
60
Forward Current If [mA]
120
150
Forward Current If [mA]
Threshold Current vs. Case Temperature
Peak Wavelength vs. Case Temperature
45
478
40
Peak Wavelength  p [nm]
Threshold Current Ith [mA]
90
35
30
25
20
15
476
474
472
470
468
0
10
20
30
40
50
60
0
10
Case Temperature Tc [ºC]
20
30
40
50
60
Case Temperature Tc [ºC]
Far Field Pattern
Relative Intensity [a.u.]
Relative Optical Output Power [a.u.]
Spectrum
-40
-20
0
20
40
Angle  [°]
468
470
472
474
Wavelength  [nm]


-2-
476
478
[ UTZ-SC0323_2 ]
2012/10/02

Cautions
(1) Safety of Laser light
 Laser beam are extremely dangerous to human eyes. Never look at laser
beam directly and/or through optical lens. When handling the LDs, wear
appropriate safety glasses to prevent laser light, even any reflections from
entering to the eye. Focused laser beam through optical instruments will
increase the chance of eye hazard.
 Nichia LDs are classified in Class 3B of IEC60825-1 and 21 CFR Part
1040.10 Safety Standards. It is absolutely necessary to take overall safety
measures against User's modules, equipment and systems into which Nichia
LDs are incorporated and/or integrated.
(2) Operating method
 The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,
the LD will require more operation current to maintain same output power as it degrades.
 Confirm that the optical output power generated by spike current when switching on and off does not exceed the
maximum absolute rating.
Also, employ appropriate countermeasures to reduce chattering and/or overshooting in
the Circuit.
(3) Static Electricity
 Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(4) Absolute Maximum Rating
 Active layer of LDs shall have high current density and generate high electric field during its operation.
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
In order to
(5) Others
 Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales
staff in advance for information on the applications in which exceptional quality and reliability are required,
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support
systems and safety devices).
 The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
 Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
 The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
 No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-