Datasheet

For more information, please visit the product page.
date
07/07/2014
page
1 of 6
SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
3 W isolated output
smaller package
single/dual regulated output
1,500 Vdc isolation
continuous short circuit
temperature range (-40~105°C)
high efficiency at light load
efficiency up to 84%
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PQMC3-D5-S5-S
5
4.5~9
5
25
500
2.5
75
73
PQMC3-D5-S9-S
5
4.5~9
9
14
278
2.5
75
74
PQMC3-D5-S12-S
5
4.5~9
12
10
208
2.5
75
77
PQMC3-D5-S15-S
5
4.5~9
15
8
167
2.5
75
74
PQMC3-D5-D5-S
5
4.5~9
±5
±13
±250
2.5
75
74
PQMC3-D5-D12-S
5
4.5~9
±12
±5
±104
2.5
75
77
PQMC3-D5-D15-S
5
4.5~9
±15
±4
±83
2.5
75
77
PQMC3-D12-S3-S
12
9~18
3.3
38
758
2.5
75
75
PQMC3-D12-S5-S
12
9~18
5
30
600
3
75
76
PQMC3-D12-S9-S
12
9~18
9
17
333
3
75
79
PQMC3-D12-S12-S
12
9~18
12
13
250
3
75
82
PQMC3-D12-S15-S
12
9~18
15
10
200
3
75
83
PQMC3-D12-S24-S
12
9~18
24
6
125
3
75
81
PQMC3-D12-D5-S
12
9~18
±5
±15
±300
3
75
78
PQMC3-D12-D12-S
12
9~18
±12
±6
±125
3
75
79
PQMC3-D12-D15-S
12
9~18
±15
±5
±100
3
75
80
PQMC3-D24-S3-S
24
18~36
3.3
38
758
2.5
75
74
PQMC3-D24-S5-S
24
18~36
5
30
600
3
75
81
PQMC3-D24-S9-S
24
18~36
9
17
333
3
75
83
PQMC3-D24-S12-S
24
18~36
12
13
250
3
75
83
PQMC3-D24-S15-S
24
18~36
15
10
200
3
75
83
PQMC3-D24-S24-S
24
18~36
24
6
125
3
75
83
PQMC3-D24-D5-S
24
18~36
±5
±15
±300
3
75
79
PQMC3-D24-D9-S
24
18~36
±9
±8
±167
3
75
81
PQMC3-D24-D12-S
24
18~36
±12
±6
±125
3
75
83
PQMC3-D24-D15-S
24
18~36
±15
±5
±100
3
75
83
PQMC3-D48-S3-S
48
36~75
3.3
38
758
2.5
75
75
PQMC3-D48-S5-S
48
36~75
5
30
600
3
75
76
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
MODEL
(CONTINUED)
input
voltage
date 07/07/2014 │ page 2 of 6
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
PQMC3-D48-S12-S
48
36~75
12
13
250
3
75
80
PQMC3-D48-S15-S
48
36~75
15
10
200
3
75
84
PQMC3-D48-S24-S
48
36~75
24
6
125
3
75
82
PQMC3-D48-D5-S
48
36~75
±5
±15
±300
3
75
79
PQMC3-D48-D12-S
48
36~75
±12
±6
±125
3
75
82
PQMC3-D48-D15-S
48
36~75
±15
±5
±100
3
75
82
Notes:
1. ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PQMC3 - DXX - XXX -S
Base Number
Output
S = single
D = dual
Input Voltage
Packaging Style
SIP
Output Voltage
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
4.5
9
18
36
5
12
24
48
9
18
36
75
Vdc
Vdc
Vdc
Vdc
start-up voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
3.5
4.5
11
24
4
8
16
33
4.5
9
18
36
Vdc
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
5 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
-0.7
-0.7
-0.7
-0.7
12
25
50
100
Vdc
Vdc
Vdc
Vdc
filter
capacitance filter
models ON (CTRL open or insulated)
CTRL2
Notes:
models OFF (connect voltage, current into CTRL is
5~10mA)
2. See application notes on page 6.
OUTPUT
parameter
conditions/description
typ
max
units
line regulation
full load, input voltage from low to high
±0.2
±0.5
%
load regulation
5% to 100% load
±0.6
±1
%
voltage accuracy
5% to 100% load
±1
±3
%
no-load voltage accuracy
PQMC3-D12-S3-S & PQMC3-D48-S3-S
all other models
±1.5
±8
±5
%
%
voltage balance3
dual output, balanced loads
±0.5
±1
switching frequency
100% load, nominal input voltage, PFM mode
250
transient recovery time
25% load step change
0.5
3
ms
transient response deviation
25% load step change
±2.5
±5
%
temperature coeffecient
100% load
±0.02
±0.03
%/°C
Notes:
min
3. For dual output models, unbalanced loads should not exceed ±5%. If ±5% is exceeded, it may not meet all specifications.
cui.com
%
kHz
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
date 07/07/2014 │ page 3 of 6
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022, class B (external circuit required, see Figure 1-b)
radiated emissions
CISPR22/EN55022, class B (external circuit required, see Figure 1-b)
ESD
IEC/EN61000-4-2, class B, contact ± 4kV
radiated immunity
IEC/EN61000-4-3, class A, 10V/m
EFT/burst
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
surge
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
conducted immunity
IEC/EN61000-4-6, class A, 3 Vr.m.s
voltage dips & interruptions
IEC/EN61000-4-29, class B, 0%-70%
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
1,000,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
105
°C
-55
125
°C
95
%
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta=25°C
typ
25
°C
SOLDERABILITY
parameter
conditions/description
hand soldering
wave soldering
min
typ
max
units
1.5 mm from case for 10 seconds
300
°C
see wave soldering profile
260
°C
max
units
MECHANICAL
parameter
conditions/description
dimensions
22.00 x 9.50 x 12.00 (0.866 x 0.374 x 0.472 inch)
min
case material
plastic (UL94-V0)
typ
mm
weight
4.9
g
DERATING CURVES
Wave Soldering Profile
Temperature Derating Curve
Peak Temp. 260°C Max.
Wave Soldering Time
4 Sec. Max.
250
100
Load (%)
Temperature (°C)
200
10 Sec. Max.
150
100
80
60
Safe operating area
40
20
50
0
-40
-20
0
20
40
60
85
Ambient Temperature (°C)
Time (sec.)
cui.com
105
120
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
date 07/07/2014 │ page 4 of 6
MECHANICAL DRAWING
PIN CONNECTIONS
Ø1.00 [0.039]
0.50[0.020]
12.00
[0.472]
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN
Single Output
Dual Output
1
GND
GND
2
Vin
Vin
Front View
3
Ctrl
Ctrl
22.00 [0.866]
5
NC
NC
6
+Vo
+Vo
7
0V
0V
8
CS
-Vo
1
2
3
5
6
2
2.50
[0.098]
1
NC: No Connection
3
5
PCB Layout
Top View
2.54[0.100]
0.30 [0.012]
9.50
[0.374]
4.10 [0.161]
6
7
8
0.50[0.020]
17.78 [0.700]
Bottom View
EMC RECOMMENDED CIRCUIT
L D M2
L D M1
FU SE
Vi n
Vi n
+
Figure 1
TVS
MO V
GND
C0
(a)
C trl
C1
D1
Cd
(c)
CY
EUT
C trl
C2
(b)
+Vo
R
GND
L O AD
-Vo
(0 V)
Recommended external circuit components
Vin (Vdc)
5
FUSE
12
24
48
choose according to practical input current
MOV
--
--
S14K35
S14K60
LDM1
--
--
56μH
56μH
TVS
SMCJ13A
SMCJ28A
SMCJ48A
SMCJ90A
C0
680μF/16V
680μF/25V
330μF/50V
330μF/100V
C1
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/100V
Table 1
LDM2
12μH
12μH
12μH
12μH
C2
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/100V
CY
1nF/2kV
1nF/2kV
1nF/2kV
1nF/2kV
D1
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
RB160M-60/1A
VC − VD − 1.0
−300
aaaaaaaaaaaa
IC
R=
Follows:aaaaa
R
Cd
47nF/100V
47nF/100V
47nF/100V
47nF/100V
Note: Figure 1-c is on/off control circuit. See page 6 for details.
TEST CONFIGURATION
Oscilloscope
Lin
Figure 2
Cin
External components
Current
Probe
DC DC
Load
Table 2
Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
Lin(4.7µH)
Cin(220µF, ESR < 1.0Ω at 100 KHz)
cui.com
Lin
4.7μH
Cin
220μF, ESR < 1.0Ω
at 100 KHz
7
8
Grid Size:
2.54mm x 2.54mm
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
date 07/07/2014 │ page 5 of 6
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 5% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Recommended circuit
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should
be tested under load (see Figure 3 and Table 3). If you want to further decrease the input/output ripple, you can increase the
capacitance accordingly or choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be
appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable
operation, the maximum capacitance must be less than the maximum capacitive load (see Table 4).
Single output
/LQ 9LQ
Dual output
9R
/LQ 9LQ
&V
' ,F 5
&RXW
9R
&RXW
*1'
&G
9F
/RXW
&LQ &LQ
&LQ &LQ
*1'
9
9F
&G
' ,F 5
9R
9
&RXW
/RXW
Figure 3
Table 3
Table 4
Vin
(Vdc)
Cin1
(µF)
Cin2
(µF)
Lin
(µH)
Cs1
(µF)
Cout
(µF)
Lout2
(µH)
Cd
(nF/V)
5
100
47
4.7~12
10~22
100
2.2~10
47/100
12
100
47
4.7~12
10~22
100
2.2~10
47/100
24
10
1
4.7~12
10~22
100
2.2~10
47/100
48
10
1
4.7~12
10~22
100
2.2~10
47/100
Note:
Single
Vout
(Vdc)
Max. Capacitive
Load
(μF)
Dual
Vout
(Vdc)
Max. Capacitive
Load1
(μF)
3.3
2700
--
--
5
2200
5
1000
9
1000
9
680
12
680
12
470
1. For single output only
2. For dual output only
15
470
15
330
24
330
Note:
--
--
1. For each output.
3. CTRL Terminal
When open or applied high impedance, the converter will turn on. When it’s pulled high, the converter will shutdown. The input
current should between 5~10mA. Exceeding the maximum 20mA will cause permanent damage to the converter. The value for R can
be derived as follows:
V − VD − 1.0
−300
R= C
IC
Vi n
Vc: Control pin input voltage
VD: Forward voltage drop of diode D1
IC: Input current to control pin
R: Resistor of control circuit
Figure 4
Vc
D1
+Vo
R
EUT
C trl
Cd
GND
L O AD
-Vo
(0 V)
Figure 5
Input Current(A)
4. Input Current
When it is used in an unregulated condition, make sure that the input fluctuations and ripple voltage do not exceed the module
standard. Refer to Figure 5 and Table 5 for the startup current of this dc-dc module.
Ip
Table 5
Input Voltage
Range
Input Voltage (V)
Note:
Vin
(Vdc)
Ip
(mA)
5
1110
12
640
24
325
48
160
1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may not meet all specifications listed.
2. Maximum capacitive load is tested at input voltage range and full load.
3. All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PQMC3-S │ DESCRIPTION: DC-DC CONVERTER
date 07/07/2014 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
03/19/2013
1.01
added models, updated spec
07/07/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.