Model 23 Multidial

Model 23 Multidial
www.vishay.com
Vishay Spectrol
Mounting Instructions
1. Drill panel as in Fig. 1.
2. Mount potentiometer in panel hole (Fig. 2) such that the end of the potentiometer spindle is between 12 mm and 20 mm
from the panel. Under these conditions the potentiometer mounting bush should not project more that 4 mm from the front
of the panel.
3. Fit anti-rotation washer onto front panel utilizing potentiometer fixing nut.
4. Rotate potentiometer spindle fully anti-clockwise.
5. Slide dial mechanism onto potentiometer spindle and locate mechanism anti-rotation spigot in washer slot.
6. Whilst gently holding the dial mechanism in place against the panel, rotate dial anti-clockwise until the reading is zero and
firmly tighten the allen screw onto the spindle using the key provided.
7. Check operation of dial, and readjust zero setting if necessary.
10
Ø2
Ø 9.6
Fig. 1 - Panel drilling (mm)
Dial mechanism
Anti-rotation
washer
Panel
Fig. 2 -
Revision: 10-Aug-12
Document Number: 57111
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000