Datasheet

UNISONIC TECHNOLOGIES CO., LTD
TGBR5V60
Preliminary
DIODE
TRENCH MOS SCHOTTKY
BARRIER RECTIFIER

DESCRIPTION
The UTC TGBR5V60 is a trench mos schottky barrier rectifier, it
uses UTC’s advanced technology to provide customers with low
forward voltage drop and high switching speed, etc.

FEATURES
* Very low forward voltage drop
* High switching speed


SYMBOL
ORDERING INFORMATION
Ordering Number
Package
Lead Free
Halogen Free
TGBR5V60L-TN3-R
TGBR5V60G-TN3-R
TO-252
Note: Pin Assignment: A: Anode K: Common Cathode

Pin Assignment
1
2
3
A
K
A
Packing
Tape Reel
MARKING
www.unisonic.com.tw
Copyright © 2016 Unisonic Technologies Co., Ltd
1 of 3
QW-R232-035.a
TGBR5V60

Preliminary
DIODE
ABSOLUTE MAXIMUM RATINGS (TA=25°C, unless otherwise specified)
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
PARAMETER
SYMBOL
RATINGS
UNIT
DC Blocking Voltage
VRM
60
V
Working Peak Reverse Voltage
VRWM
60
V
Repetitive Peak Reverse Voltage
VRRM
60
V
Average Rectified Output Current
IO
5
A
Non-Repetitive Peak Forward Surge Current 8.3ms
IFSM
100
A
Single Half Sine-Wave Superimposed on Rated Load
Operating Junction Temperature
TJ
-65 ~ +150
°C
Storage Temperature
TSTG
-65 ~ +150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

THERMAL CHARACTERISTICS (PER LEG)
PARAMETER
Typical Thermal Resistance

SYMBOL
θJC
RATINGS
6
UNIT
°С/W
ELECTRICAL CHARACTERISTICS (PER LEG) (TA =25°C, unless otherwise specified)
PARAMETER
Reverse Breakdown Voltage
SYMBOL
TEST CONDITIONS
V(BR)R
IR=0.5mA
IF=5A, TJ=25°C
Forward Voltage Drop
VFM
IF=5A, TJ=125°C
VR=60V, TJ=25°C
Leakage Current
IRM
VR=60V, TJ=125°C
Note: Pulse Test: Pulse width ≤ 300µs, Duty cycle ≤ 2%.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
60
TYP MAX UNIT
V
0.58
V
0.53
V
300 μA
30
mA
2 of 3
QW-R232-035.a
TGBR5V60
Preliminary
DIODE
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R232-035.a