(L)QFP(64 80 100)20160315

Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Page 1 of 7.
HANGZHOU SILAN MICROELECTRONICS CO.,LTD .
NO.4 HUANGGUSHAN ROAD,HANGZHOU,ZHEJIANG
CHINA.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : (L)QFP(64 80 100) .
SGS Job No. :
CP16-010639 - GZ .
Model No. :.
SC6135B.
Client Ref. Info. : .
SC9711, SC6135B, SC6138A, SC7001Q, SC75823W, SC6131A, SC6132B,
SQ96A82, SQ96B82, SC9659P, SC75823E, SC9636-006, SC9637B, SC9640P .
Date of Sample Received : .
07 Mar 2016.
Testing Period : .
07 Mar 2016 - 14 Mar 2016 .
Test Requested : .
Selected test(s) as requested by client. .
Test Method : .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Conclusion :.
Based on the performed tests on submitted sample(s), the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs),
Polybrominated diphenyl ethers (PBDEs) and Phthalates such as
Bis(2-ethylhexyl) phthalate (DEHP) , Butyl benzyl phthalate (BBP), Dibutyl
phthalate (DBP) , and Diisobutyl phthalate (DIBP) comply with the limits as set by
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. .
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch.
Echo Yeung.
Approved Signatory .
Kenny Wang.
Approved Signatory .
Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Page 2 of 7.
Test Results :.
Test Part Description : .
Specimen No..
SN1.
SGS Sample ID.
CAN16-032409.003
Description.
Black plastic w/ chip & brown printing .
SN2.
CAN16-032409.004
Silvery metal pin .
Remarks :.
(1) 1 mg/kg = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5)With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS.
(6)With reference to EN 14372:2004, determination of phthalates by GC-MS. .
Test Item(s).
Limit.
Unit.
MDL.
003.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
ND
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (CrVI) .
1,000
mg/kg.
2
ND
Sum of PBBs .
1,000
mg/kg.
-
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
Decabromobiphenyl .
-
mg/kg.
5
ND
Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Test Item(s).
Limit.
Unit.
Sum of PBDEs .
MDL.
003.
1,000
mg/kg.
-
ND
Monobromodiphenyl ether .
-
mg/kg.
5
ND
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Dibutyl phthalate (DBP) .
1,000
mg/kg.
30
ND
Butyl benzyl phthalate (BBP) .
1,000
mg/kg.
30
ND
Bis (2-ethylhexyl) phthalate (DEHP) .
1,000
mg/kg.
30
ND
Diisobutyl Phthalates (DIBP) .
1,000
mg/kg.
30
ND
Page 3 of 7.
Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. .
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321-7-1:2015 , determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis. .
Test Item(s).
Limit.
Unit.
MDL.
004.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
5
Mercury (Hg).
1,000
mg/kg.
2
ND
-.
µg/cm².
0.10
ND
Hexavalent Chromium (Cr(VI))▼ .
Notes :.
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(2) ▼= a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm2. The
sample coating is considered to contain CrVI
b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm2). The
coating is considered a non-CrVI based coating
c. The result between 0.10 μg/cm2 and 0.13 μg/cm2 is considered to be inconclusive -
Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Page 4 of 7.
unavoidable coating variations may influence the determination
Information on storage conditions and production date of the tested sample is unavailable
and thus Cr(VI) results represent status of the sample at the time of testing.
IEC 62321 series is equivalent to EN 62321 series
http://www.cenelec.eu/dyn/www/f? p=104:30:1742232870351101::::FSP_ORG_ID,
FSP_LANG_ID:1258637,25 .
Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Page 5 of 7.
ATTACHMENTS
Pb/Cd/Hg/Cr6+/PBBs/PBDEs Testing Flow Chart
1) Name of the person who made testing: Bruce Xiao / Sunny Hu
2) Name of the person in charge of testing: Bella Wang / Cutey Yu
3) These samples were dissolved totally by pre-conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded ).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
Residue
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
Cr6+
PBBs/PBDEs
GC-MS
DATA
Nonmetallic
material
Metallic
material
Adding digestion
reagent
Boiling water
extraction
Heating to
90~95℃ for
extraction
Filtration and
pH adjustment
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
DATA
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
DATA
Test Report.
No. CANEC1603240903
ATTACHMENTS
Phthalates Testing Flow Chart
1) Name of the person who made testing: Sunny Hu
2) Name of the person in charge of testing: Cutey Yu
Sample cutting / preparation
Sample Measurem ent
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Date: 15 Mar 2016 .
Page 6 of 7.
Test Report.
No. CANEC1603240903
Date: 15 Mar 2016 .
Sample photo: .
CANEC1603240903
CAN16-032409.003 .
CANEC1603240903
CAN16-032409.004 .
SGS authenticate the photo on original report only .
*** End of Report *** .
Page 7 of 7.