15-pin High-Density D-Subminiature Field Terminating Insert Installaition Instructions: PN389B

15-pin High-Density D-Subminiature
Field Terminating Insert
Part Number: CHD15HDSC**Y
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2014
PN389B
INTRODUCTION
The screw-down type 15-pin D-sub connector is designed for use with video cables
having (3) coax lines (R,G,B) and (4) twisted pair lines with (2) conductor lines and a
drain wire. Numerous configurations of video cables exist, signal names are given to
accommodate the various video cable types with different conductor colors.
RECOMMENDED TOOLS
- 2mm slotted screwdriver
- Wire cutters
- Wire strippers
- Cable stripper
CHD15HDSC**Y
STEP 1
Trim back video cable to expose conductors.
1 - Drain wire
4 - Twisted pair conductors
(TP)
Center conductor(CC)
Outer conductor shield(SHLD)
3 - COAX: Red, Green, Blue
2 - Conductors(COND)
1" approximately
2" approximately
** Denotes color.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
PN389B
STEP 2
PINOUT TABLE
Identify conductor to appropriate signal
name per pinout table.
Due to the wide variety of video cable:
1. There is no standard color code for
the conductors other than the coaxial
Red, Green, and Blue.
2. The only certain way to identify
correct conductors is to perform a
continuity test.
3. There may be unused conductors for
your application.
PIN
1
2
3
*4
5
6
7
8
9
*10
*11
12
13
14
15
16
SIGNAL
WIRE
COAX CC
COAX CC
COAX CC
TP
TP
COAX SHLD
COAX SHLD
COAX SHLD
N/C
TP
TP
TP
COND 1
COND 2
N/C
DRAIN WIRE
RED
GREEN
BLUE
ID BIT 2
GROUND
RED SHIELD
GREEN SHIELD
BLUE SHIELD
NO CONNECTION
SYNC RTN
ID BIT 0
ID BIT 1
HORZ SYNC
VERT SYNC
ID BIT 3
SHELL
* Wires connected together
Greyed connections are optional
STEP 3
Before inserting wires for termination, turn
screws counter-clockwise to ensure all
clamps are completely open. (See Fig. 1)
Insert coaxial center conductors, coaxial
shields, and conductors into appropriate
slots of terminal board by signal name in
accordance with the pinout table.
OPEN
HALF
OPEN
CLOSED
Fig. 1
Turn screws clockwise to ensure all clamps
are properly closed and wires are secure.
E-mail:
[email protected]
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 2
Phone:
866-405-6654