SES5VSC70-6

Surge Components, Inc.
1.FEATURE
100 Watts Peak Power per Line(tp=8/20us)
SC-70-6L package
Protect 4 lines bidirectional and 5 lines unidirectional
Monolithic structure
Working woltage: 5V
Low clamping voltage
ESD protection > 15KV
Low leakage current
RoHS compliant
Transient protection for data lines to IEC 61000-4-2(ESD) ± 15KV (air),
± 8KV (contact); IEC 61000-4-4 (EFT) 40A (5/50ns)
2. APPLICATION
Cellular phones
MP3 players
Notebook
PDAs
Digital cameras
Cellular phones station
3. ELECTRICAL CHARACTERISTICS PER LINE@25℃
℃(UNLESS OTHERWISE SPECIFIED)
Parameter
Reverse stand-off voltage
Reverse Breakdown voltage
Reverse Leakage Current
Clamping Voltage
Clamping voltage
Junction Capacitance
Symbol
VRWM
VBR
IR
VC
VC
CJ
Conditions
It=1mA
VRWM=5V T=25℃
IPP=1A TP=8/20uS
IPP=10A TP=8/20uS
VR=0V f=1MHz
Min.
Typ.
Max.
Units
5
V
V
uA
V
V
pF
6
5
8.8
10.0
60
Note 1: Pin 1,3,4,5 or 6 to Pin 2
2
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
4. ABSOLUTE MAXIMUM RATING @25℃
℃ NOTE 1
Rating
Symbol
Value
Units
Peak Pulse Power(tp=8/20µs)
PPP
100
W
Forward voltage@1A, 8/20µs
VF
1.5
V
Operating Temperature
Tj
-55 to +150
℃
TSTG
-55 to +150
℃
Storage Temperature
Note 1: Pin 1,3,4,5 or 6 to Pin 2
5.TYPICAL CHARACTERISTICS
3
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
4
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
5
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
6. PRODUCT DIMENSION
DIM
A
B
C
D
E
F
G
J
K
L
M
MOUNTING PAD
DIM
1
2
3
4
5
6
7
TYPICAL
Millimeter
Inches
0.50
0.020
1.30
0.051
0.65
0.026
1.72
0.068
0.60
0.024
1.11
0.044
2.33
0.092
PACKAGE OUTLINE
MILIMETER
INCHES
MIN
MAX
MIN
MAX
1.90
2.15
0.075
0.085
1.15
1.35
0.045
0.053
0.80
1.00
0.031
0.039
0.15
0.30
0.006
0.012
0.65 BSC
0.026 BSC
1.30 BSC
0.051 BSC
0.80
1.10
0.031
0.043
0.08
0.25
0.003
0.010
1.90
2.15
0.075
0.085
0
0.10
0
0.004
0.26
0.46
0.010
0.018
NOTES
TAPE & REEL ORDERING NOMENCLATURE
1. Surface mount product is taped and reeled in
accordance with EIA-481.
2. 7 Inch Reel – 3,000 pieces per 8mm tape.
6
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
7. PACKING INFORMATION
Reel Dia
178mm(7”)
Tape Width
8mm
AO
BO
KO
D
E
F
W
PO
P2
P
Imax
2.25±0.10
2.34±0.10
1.22±0.10
1.50±0.10
1.75±0.10
3.50±0.05
8.00±0.30
4.00±0.10
2.00±0.005
4.00±0.005
0.25
8. APPLICATION NOTE
The SES5VSC70-6 is TVS arrays designed to protect I/O or data lines from the damaging effects of ESD
or EFT. This product provides both unidirectional and bidirectional protection, with a surage capability of
100 watts Ppp line for an 8/20µs wave shape and ESD protection > 25kv.
Common-mode unidirectional configuration (Figure 1)
The SES5VSC70-6 provides up to 5 lines of protection in a common-mode unidirectional configuration
as depicted in Figure 1.
Circuit connectivity is as follows:
■ Line 1 is connected to Pin1.
■ Line 2 is connected to Pin3.
■ Line 3 is connected to Pin4.
■ Line 4 is connected to Pin6
■ Line 5 is connected to Pin5.
■ Pin2 is connected to ground.
Common-mode unidirectional configuration (Figure 2)
7
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818
Surge Components, Inc.
The SES5VSC70-6 provides up to 4 lines of protection in a common-mode bidirectional configuration
as depicted in Figure 2.
Circuit connectivity is as follows:
■ Line 1 is connected to Pin1.
■ Line 2 is connected to Pin3.
■ Line 3 is connected to Pin4
■ Line 4 is connected to Pin6
■ Pin5 is connected to ground.
■ Pin2 is not connected.
Differential-mode bidirectional configuration (Figure 3)
The SES5VSC70-5 provides up to 4 lines of protection in a differential-mode bidirectional configuration
as depicted in Figure 3.
Circuit connectivity is as follows:
■ Line 1 is connected to Pin1.
■ Line 2 is connected to Pin3.
■ Line 3 is connected to Pin4.
■ Line 4 is connected to Pin6.
■ Line 5 is connected to Pin5.
■ Pin2 is not connected.
Circuit board layout and protection device placement:
Circuit board layout is critical for suppression of ESD transients.
The following guidelines are recommended:
1. Place the protection devices as close to the input terminal or connector as possible.
2. The path length between the protection device and protected line should be minimized.
3. Keep parallel signal pats to a minimum.
4. Avoid running protection conductors in parallel with unprotected conductor.
5. Minimize all printed-circuit board conductive loops including power and ground loops.
6. minimize the length of the transient return path to ground.
7. Avoid using shared transient return paths to common ground point.
8. Ground planes should be used whenever possible. For multilayer printed-circuit boards, use
ground vias
8
95 East Jefryn Blvd
Deer Park, NY
11729
(631) 595-1818