Downloads for PC Mount Split Pack™ Power Transformers (FS10-110)

P OWE R T RAN S FO R M E R
P C M O U N T : SPLIT PACK
FS10-110
Description:
The FS10-110 is a dual primary and dual secondary, split bobbin design which
operates with either a parallel input of 115V or a series input of 230V. The output
voltage will be either 10.0V with a center-tap under a 0.11A load with the
secondaries wired in series, or 5.0V under a 0.22A load with the secondaries
wired in parallel. The split bobbin design eliminates the need for costly
electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 1.1VA
2. Primary:
Series: 230V; Parallel: 115V
3. Secondary: Series: 10.0V CT@ 0.11A; Parallel: 5.0V @ 0.22A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
This model is also available in Class 2, UL 5085-3 (1585) version as FS10-110-C2
H
Dimensions:
H
W
0.937 1.125
Weight: 0.17 lbs
Units in inches.
L
1.375
A
0.250
B
0.250
C
1.200
D
0.041
E
0.020
F
0.234
1
3
2
4
D
F
Schematic:
PARALLEL
115/230V
50/60Hz
1
5
2
3
6
7
4
8
SERIES
1
115/230V
50/60Hz
2
3
A
1
115/230V
50/60Hz
4
A
5
2
3
8
B
4
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
1
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2 and
5085-3, respectively.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
4
0.06" DIAMETER
HOLE
Board Layout
Publish Date: December 4, 2013