Downloads for Single Secondary Chassis Mount Power Transformers (F-117X)

P OWER TRANS FOR MER
Chassis Mount: Single Secondary
F-117X
Electrical Specifications (@25C)
1. Maximum Power: 9.6 VA
2. Primary: 115V 50/60 Hz
3. Secondary: 24.0VCT @ 0.400 Amps
4. Voltage Regulation: 20 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-117X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
A
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
BLK
BLK
Dimensions:
A
B
1.625
2.812
Units: In inches
C
1.625
D
2.375
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 0.80 lbs
C
Schematic:
BLK
RED
B D
R/Y
RED
BLK
Primary:
Black to Black
Secondary: Red to Red
RED
R/Y
RED
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013