Downloads for Single Secondary Chassis Mount Power Transformers (F-46X)

P OWE R T RAN S FO R M E R
Chassis Mount: Single Secondary
F-46X
Electrical Specifications (@25C)
1. Maximum Power: 24.0 VA
2. Primary: 115V 60 Hz
3. Secondary: 24.0V @ 1.00 Amps
4. Voltage Regulation: 10 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-46X is part of a series which has a long history of reliable service in the field,
made from a proven design and constructed with UL recognized materials.
A
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
BLK
BLK
Units: In inches
A
B
C
D
1.937
3.250
2.125
2.812
C
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 1.40 lbs
Schematic:
B
BLK
GRN
BLK
GRN
D
Primary:
Black to Black
Secondary: Green to Green
G RN
G RN
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571