Downloads for Chassis Mount Quick Pack™ Power Transformers (F5-120)

Power Transformer
Chassis Mount: Quick Pack
F5-120
Description:
The F5-120 Quick Pack small power transformer offers a significant reduction
in size and weight over a standard transformer. This transformer can be used
for a wide variety of applications. It is bobbin wound for reduced size and small
operating space.
Electrical Specifications (@25C);
Maximum Power: 12.0VA
Input Voltage: 115VAC@50/60Hz
Output Voltage: [email protected]
Hipot: 2500VAC primary to secondary; 1500VAC windings to core.
Construction:
Split bobbin non concentric winding eliminates costly electrostatic shielding.
Termination is suitable for quick connects or soldering.
Built with UL Class B Insulation System.
E
8
7
4
3
5
Safety:
UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose.
A
C
D
E
F
G
1.625
2.375
2.812
1.375
1.937
.187 Dia
.812
B
Notes: 1. Units: inches.
2. Terminal size: .187” X 0.021”.
3. Weight: .70 lbs
3
B
1
2
A
2
1
Dimensions:
4
F
D
G
Schematic:
2
5
C
7
3
8
Input: Input 2 & 3
Output: 5 to8
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571