6T50W

ATTENUATORS
TNC
18 GHz
50 WATTS
UP TO
SPECIFICATIONS:
Frequency Range
Standard Freq. Values
Standard dB Values
Attenuation Accuracy
3, & 6 dB
10 & 20 dB
30 dB
40 dB
VSWR
DC - 6 GHz
6 - 12.4 GHz
12.4 - 18 GHz
Input Power
DC - 6 GHz
±0.75 dB
±0.75 dB
±0.75 dB
±1.00 dB
DC - 18.0 GHz
2.5, 6,12.4 & 18 GHz
3, 6, 10, 20, 30 & 40 dB
6 - 12.4 GHz 12.4 - 18 GHz
±0.75 dB
±0.75 dB
±1.00 dB
±0.75 dB
±1.00 dB
±1.25 dB
±1.25 dB
±1.50 dB
3.50±.02
[88.90±0.51]
2.65±.02
[67.31±0.51]
1.25:1 Max.
1.35:1 Max.
1.45:1 Max.
50 Watts Avg. @ 25°C
Peak Power
500 Watts Max.
Impedance
Operating Temp Range
TNC Connectors**
Conductors
Housing
END VIEW
TYPICAL
50 Ohms
-65°C to +125°C
Passivated Stainless Steel
Gold Plated Beryllium Copper
Anodized Aluminum
**TNC Connectors are 18 GHz Mode-Free
Units must be Mounted in such a way as to
Allow for Free Air Flow Around fins to Insure
Performance
Note: Units are Unidirectional, Therefore Input Connector MUST be Specified & will be Indicated on Unit
Model Number:
Pictured
XXT50W-XX
4.65±.05
[118.11±1.27]
1.25
[31.75]
Model Number: XXT50W-XXF
Female/Female Connectors
Length: 4.75 ±.05 [120.7 ±1.3]
Model Number: XXT50W-XXM
Male/Male Connectors
Length: 4.56 ±.05 [115.8 ±1.3]
HOW TO ORDER:
Model Number: XXT50W-XXY
Freq. Range
2 = DC - 2.5 GHz
6 = DC - 6 GHz
12 = DC - 12.4 GHz
18 = DC - 18 GHz
INPUT
.25 [6.35]
2X 8-32UNC-2B TAP
x .50[12.7] DP.
2X M4x0.7 TAP
x .50[12.7] DP.
Ordering Examples:
18T50W-20
Model Number:
DC - 18 GHz; 20 dB; TNC - Male/Fem (Male Input)
Connector Configuration
= Male/Female (Male Input)
6T50W-03F
Model Number:
F = Fem/Fem
DC - 6 GHz; 3 dB; TNC - Fem/Fem
M = Male/Male
FM = Female/Male (Female Input)
6T50W-10FM
Model Number:
dB Value
DC - 6 GHz; 10 dB; TNC - Fem/Male (Female Input)
Note: Dimensions in Brackets are Expressed in Millimeters and are for Reference Only.
Design specifications are subject to change without notice.
Contact factory for technical specifications before purchasing or use.
Similar pages