M39006/09, M39006/21 Datasheet

M39006/09, M39006/21
www.vishay.com
Vishay
Wet Tantalum Capacitors, Military Established Reliability,
MIL-PRF-39006/09/21 Qualified Styles CLR65, CLR69
FEATURES
• Hermetically sealed
• Metal cased
• Axial lead
• Tubular
STYLE, MILITARY SPECIFICATION
• CLR65, M39006/09 MIL-PRF-39006/09
• CLR69, M39006/21 MIL-PRF-39006/21
PERFORMANCE CHARACTERISTICS
Operating Temperature: -55 °C to +125 °C
(above 85 °C, voltage derating is required)
Capacitance Range: M39006/09 - 1.7 μF to 1200 μF;
M39006/21 - 6.8 μF to 2200 μF
Capacitance Tolerance: ± 5 %, ± 10 %, ± 20 %
Voltage Rating: 6 VDC to 125 VDC
For information on the performance characteristics of these
capacitors, please refer to the latest issue of the military
specification.
Established Reliability Tantalum Capacitors to Military
Specification MIL-PRF-39006: in accordance with the
military specification MIL-PRF-39006 all capacitors are
marked with the military part number (M39006/xx-xxxx)
rather than the older style designation (CLR65, CLR69) and
should be ordered as such.
Each order for military style capacitors requiring
government inspection must state whether inspection is to
be at the destination or at the Vishay plant. Orders requiring
source inspection cannot be shipped until this has been
accomplished.
ORDERING INFORMATION
M39006
/09
-8005
BASIC DOCUMENT NUMBER
SLASH SHEET
DASH NUMBER
Indicates the basic specification;
in this case MIL-PRF-39006
Indicates the specification sheet
of the basic military specification
Taken from
Standard/Extended Ratings tables
Revison: 14-Jun-16
Document Number: 40159
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
DIMENSIONS in inches [millimeters]
Style CLR65
Style CLR69
Tantalum feed-through
0.078 [1.98] max. dia.
0.250 [6.35]
max.
Terminal
welded
to case
Term. loc. within
0.031 [0.79] R
of true position
-
+
D dia.
Circuit diagram
0.094 [2.38]
max.
External
weld
E
L
Glass
0.025 ± 0.002
[0.64 ± 0.05]
E
Insulating sleeve
BARE CASE
CASE CODE
T1
T2
T3
T4
WITH INSULATING SLEEVE
D
L
D (Max.)
L (Max.)
E
LEAD LENGTH
0.188 ± 0.016
[4.78 ± 0.41]
0.281 ± 0.016
[7.14 ± 0.41]
0.375 ± 0.016
[9.53 ± 0.41]
0.375 ± 0.016
[9.53 ± 0.41]
0.453 + 0.031/- 0.016
[11.51 + 0.79/- 0.41]
0.641 + 0.031/- 0.016
[16.28 + 0.79/- 0.41]
0.766 + 0.031/- 0.016
[19.46 + 0.79/- 0.41]
1.062 + 0.031/- 0.016
[26.97 + 0.79/- 0.41]
0.219
[5.56]
0.312
[7.92]
0.406
[10.31]
0.406
[10.31]
0.515
[13.08]
0.704
[17.88]
0.828
[21.03]
1.126
[28.60]
1.500 ± 0.250
[38.10 ± 6.35]
2.250 ± 0.250
[57.15 ± 6.35]
2.250 ± 0.250
[57.15 ± 6.35]
2.250 ± 0.250
[57.15 ± 6.35]
WEIGHT
(oz./g)
(Max.)
0.07
[2.0]
0.18
[5.1]
0.36
[10.2]
0.49
[13.9]
RATINGS AND CASE CODES - M39006/09
μF
1.7
2.5
3.5
3.6
4.0
4.7
5.0
6.8
8.0
8.2
9.0
10
11
15
20
22
25
30
33
39
40
43
47
50
56
60
68
70
82
86
100
6
8
10
15
25
30
50
60
75
100
125
T1
T1
T1
T1
T1
T1
T1
T1
T1
T1
T2
T1
T1
T2
T1
T1
T2
T1
T2
T1
T2
T1
T2
T3
T1
T3
T1
T2
T2
T2
T3
T3
T1
T2
T3
T1
T3
T4
T3
T1
Revison: 14-Jun-16
T2
T3
T2
T3
T4
T2
T2
T3
Document Number: 40159
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
RATINGS AND CASE CODES - M39006/09
μF
110
120
140
150
160
170
180
220
250
270
300
330
350
390
430
540
560
750
850
1200
6
8
10
15
25
30
50
60
75
T4
100
125
75
100
125
T1
T2
T2
T4
T3
T4
T3
T2
T3
T2
T3
T2
T3
T4
T3
T4
T3
T3
T4
T3
T4
T4
T4
RATINGS AND CASE CODES - M39006/21
μF
6.8
10
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
1500
1800
2200
6
8
10
15
25
30
50
60
T1
T1
T1
T2
T1
T2
T3
T1
T1
T3
T2
T1
T4
T2
T2
T4
T1
T1
T1
T2
T2
T3
T4
T3
T4
T3
T4
T2
T2
T3
T4
T2
T2
T3
T3
T4
T3
T4
T3
T4
T3
T4
T4
Revison: 14-Jun-16
Document Number: 40159
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR65
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09FAILURE RATE
LEVEL (%/1000 h)
L
2.0
30
30
30
68
68
68
140
140
140
270
270
270
330
330
330
560
560
560
1200
1200
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T3
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8001
8002
8003
8004
8005
8006
8007
8008
8009
8010
8011
8012
8013
8014
8015
8016
8017
8018
8019
8020
25
25
25
56
56
56
220
220
220
430
430
430
850
850
T1
T1
T1
T1
T1
T1
T2
T2
T2
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8021
8022
8023
8024
8025
8026
8027
8028
8029
8030
8031
8032
8033
8034
20
20
20
47
47
47
100
100
100
180
180
180
250
250
250
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T3
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
8035
8036
8037
8038
8039
8040
8041
8042
8043
8044
8045
8046
8047
8048
8049
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/09-XXXX
MAX. DF
AT +25 °C
(%)
6 VDC AT +85 °C; 4 VDC AT +125 °C
8206
1
2
9.1
8207
1
2
9.1
8208
1
2
9.1
8209
1
2
20.4
8210
1
2
20.4
8211
1
2
20.4
8212
1
3
21.3
8213
1
3
21.3
8214
1
3
21.3
8215
1
6.5
81.8
8216
1
6.5
81.8
8217
1
6.5
81.8
8218
2
7.9
49.6
8219
2
7.9
49.6
8220
2
7.9
49.6
8221
2
13
128
8222
2
13
128
8223
2
13
128
8224
3
14
144.4
8225
3
14
144.4
8 VDC AT +85 °C; 5 VDC AT +125 °C
8226
1
2
7.6
8227
1
2
7.6
8228
1
2
7.6
8229
1
2
17
8230
1
2
17
8231
1
2
17
8232
1
7
66.4
8233
1
7
66.4
8234
1
7
66.4
8235
2
14
91.5
8236
2
14
91.5
8237
2
14
91.5
8238
4
16
65.8
8239
4
16
65.8
10 VDC AT +85 °C; 7 VDC AT +125 °C
8240
1
2
6.1
8241
1
2
6.1
8242
1
2
6.1
8243
1
2
18.1
8244
1
2
18.1
8245
1
2
18.1
8246
1
4
15.2
8247
1
4
15.2
8248
1
4
15.2
8249
1
7
54.4
8250
1
7
54.4
8251
1
7
54.4
8252
2
10
37.8
8253
2
10
37.8
8254
2
10
37.8
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
100
100
100
60
60
60
40
40
40
25
25
25
20
20
20
25
25
25
20
20
-40
-40
-40
-40
-40
-40
-40
-40
-40
-44
-44
-44
-44
-44
-44
-64
-64
-64
-80
-80
+10.5
+10.5
+10.5
+14
+14
+14
+14
+14
+14
+17.5
+17.5
+17.5
+14
+14
+14
+17.5
+17.5
+17.5
+25
+25
+12
+12
+12
+16
+16
+16
+16
+16
+16
+20
+20
+20
+16
+16
+16
+20
+20
+20
+25
+25
100
100
100
59
59
59
30
30
30
25
25
25
22
22
-40
-40
-40
-40
-40
-40
-44
-44
-44
-64
-64
-64
-80
-80
+10.5
+10.5
+10.5
+14
+14
+14
+17.5
+17.5
+17.5
+17.5
+17.5
+17.5
+25
+25
+12
+12
+12
+16
+16
+16
+20
+20
+20
+20
+20
+20
+25
+25
175
175
175
100
100
100
60
60
60
40
40
40
30
30
30
-32
-32
-32
-36
-36
-36
-36
-36
-36
-36
-36
-36
-40
-40
-40
+10.5
+10.5
+10.5
+14
+14
+14
+14
+14
+14
+14
+14
+14
+14
+14
+14
+12
+12
+12
+16
+16
+16
+16
+16
+16
+16
+16
+16
+16
+16
+16
Note
Style CLR65 is inactive for new military design. For new design use style CLR79.
(1)
Revison: 14-Jun-16
Document Number: 40159
4
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR65
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09FAILURE RATE
LEVEL (%/1000 h)
L
2.0
390
390
390
750
750
T3
T3
T3
T4
T4
20
10
5
20
10
8050
8051
8052
8053
8054
15
15
15
33
33
33
70
70
70
120
120
120
170
170
170
270
270
270
540
540
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T3
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8055
8056
8057
8058
8059
8060
8061
8062
8063
8064
8065
8066
8067
8068
8069
8070
8071
8072
8073
8074
10
10
10
22
22
22
100
100
100
180
180
180
350
350
T1
T1
T1
T1
T1
T1
T2
T2
T2
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8075
8076
8077
8078
8079
8080
8081
8082
8083
8084
8085
8086
8087
8088
8.0
8.0
8.0
15
15
15
40
40
40
T1
T1
T1
T1
T1
T1
T2
T2
T2
20
10
5
20
10
5
20
10
5
8089
8090
8091
8092
8093
8094
8095
8096
8097
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/09-XXXX
MAX. DF
AT +25 °C
(%)
10 VDC AT +85 °C; 7 VDC AT +125 °C
8255
2
16
87.6
8256
2
16
87.6
8257
2
16
87.6
8258
4
16
56.5
8259
4
16
56.5
15 VDC AT +85 °C; 10 VDC AT +125 °C
8260
1
2
5.7
8261
1
2
5.7
8262
1
2
5.7
8263
1
2
12.5
8264
1
2
12.5
8265
1
2
12.5
8266
1
4
13.1
8267
1
4
13.1
8268
1
4
13.1
8269
1
7
36.8
8270
1
7
36.8
8271
1
7
36.8
8272
2
10
25.4
8273
2
10
25.4
8274
2
10
25.4
8275
2
16
60.9
8276
2
16
60.9
8277
2
16
60.9
8278
6
24
49
8279
6
24
49
25 VDC AT +85 °C; 15 VDC AT +125 °C
8280
1
2
4.6
8281
1
2
4.6
8282
1
2
4.6
8283
1
2
8.3
8284
1
2
8.3
8285
1
2
8.3
8286
1
10
31.4
8287
1
10
31.4
8288
1
10
31.4
8289
2
18
54.3
8290
2
18
54.3
8291
2
18
54.3
8292
7
28
35
8293
7
28
35
30 VDC AT +85 °C; 20 VDC AT +125 °C
8294
1
2
4.5
8295
1
2
4.5
8296
1
2
4.5
8297
1
2
9.1
8298
1
2
9.1
8299
1
2
9.1
8300
1
5
12.2
8301
1
5
12.2
8302
1
5
12.2
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
25
25
25
23
23
-64
-64
-64
-80
-80
+17.5
+17.5
+17.5
+25
+25
+20
+20
+20
+25
+25
155
155
155
90
90
90
75
75
75
50
50
50
35
35
35
30
30
30
23
23
-24
-24
-24
-28
-28
-28
-28
-28
-28
-28
-28
-28
-32
-32
-32
-56
-56
-56
-80
-80
+10.5
+10.5
+10.5
+14
+14
+14
+14
+14
+14
+17.5
+17.5
+17.5
+14
+14
+14
+17.5
+17.5
+17.5
+25
+25
+12
+12
+12
+16
+16
+16
+16
+16
+16
+20
+20
+20
+16
+16
+16
+20
+20
+20
+25
+25
220
220
220
140
140
140
50
50
50
32
32
32
24
24
-16
-16
-16
-20
-20
-20
-28
-28
-28
-48
-48
-48
-70
-70
+8
+8
+8
+10.5
+10.5
+10.5
+13
+13
+13
+13
+13
+13
+25
+25
+9
+9
+9
+12
+12
+12
+15
+15
+15
+15
+15
+15
+25
+25
275
275
275
175
175
175
65
65
65
-16
-16
-16
-20
-20
-20
-24
-24
-24
+8
+8
+8
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+12
+12
+12
+12
+12
+12
+12
+12
+12
Note
Style CLR65 is inactive for new military design. For new design use style CLR79.
(1)
Revison: 14-Jun-16
Document Number: 40159
5
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR65
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09FAILURE RATE
LEVEL (%/1000 h)
L
2.0
68
68
68
100
100
100
150
150
150
300
300
T2
T2
T2
T3
T3
T3
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
8098
8099
8100
8101
8102
8103
8104
8105
8106
8107
8108
5.0
5.0
5.0
10
10
10
25
25
25
47
47
47
60
60
60
82
82
82
160
160
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T3
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8109
8110
8111
8112
8113
8114
8115
8116
8117
8118
8119
8120
8121
8122
8123
8124
8125
8126
8127
8128
4.0
4.0
4.0
8.2
8.2
8.2
20
20
20
39
39
39
50
50
50
68
68
68
140
140
T1
T1
T1
T1
T1
T1
T2
T2
T2
T2
T2
T2
T3
T3
T3
T3
T3
T3
T4
T4
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
8129
8130
8131
8132
8133
8134
8135
8136
8137
8138
8139
8140
8141
8142
8143
8144
8145
8146
8147
8148
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/09-XXXX
MAX. DF
AT +25 °C
(%)
30 VDC AT +85 °C; 20 VDC AT +125 °C
8303
1
8
31
8304
1
8
31
8305
1
8
31
8306
2
12
19
8307
2
12
19
8308
2
12
19
8309
2
18
46
8310
2
18
46
8311
2
18
46
8312
8
32
35
8313
8
32
35
50 VDC AT +85 °C; 30 VDC AT +125 °C
8314
1
2
3.4
8315
1
2
3.4
8316
1
2
3.4
8317
1
2
6
8318
1
2
6
8319
1
2
6
8320
1
5
11.2
8321
1
5
11.2
8322
1
5
11.2
8323
1
9
21.4
8324
1
9
21.4
8325
1
9
21.4
8326
2
12
13.6
8327
2
12
13.6
8328
2
12
13.6
8329
2
16
24.9
8330
2
16
24.9
8331
2
16
24.9
8332
8
32
25.7
8333
8
32
25.7
60 VDC AT +85 °C; 40 VDC AT +125 °C
8334
1
2
3
8335
1
2
3
8336
1
2
3
8337
1
2
5
8338
1
2
5
8339
1
2
5
8340
1
5
7.6
8341
1
5
7.6
8342
1
5
7.6
8343
1
9
20.7
8344
1
9
20.7
8345
1
9
20.7
8346
2
12
15.3
8347
2
12
15.3
8348
2
12
15.3
8349
2
16
30.7
8350
2
16
30.7
8351
2
16
30.7
8352
8
32
25.7
8353
8
32
25.7
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
60
60
60
40
40
40
35
35
35
25
25
-24
-24
-24
-28
-28
-28
-48
-48
-48
-60
-60
+13
+13
+13
+10.5
+10.5
+10.5
+13
+13
+13
+25
+25
+15
+15
+15
+12
+12
+12
+15
+15
+15
+25
+25
400
400
400
250
250
250
95
95
95
70
70
70
45
45
45
45
45
45
27
27
-16
-16
-16
-24
-24
-24
-20
-20
-20
-28
-28
-28
-16
-16
-16
-32
-32
-32
-50
-50
+5
+5
+5
+8
+8
+8
+10.5
+10.5
+10.5
+13
+13
+13
+10.5
+10.5
+10.5
+13
+13
+13
+25
+25
+6
+6
+6
+9
+9
+9
+12
+12
+12
+15
+15
+15
+12
+12
+12
+15
+15
+15
+25
+25
550
550
550
275
275
275
105
105
105
90
90
90
50
50
50
50
50
50
28
28
-16
-16
-16
-24
-24
-24
-16
-16
-16
-28
-28
-28
-16
-16
-16
-32
-32
-32
-40
-40
+5
+5
+5
+8
+8
+8
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+10.5
+20
+20
+6
+6
+6
+9
+9
+9
+12
+12
+12
+12
+12
+12
+12
+12
+12
+12
+12
+12
+20
+20
Note
Style CLR65 is inactive for new military design. For new design use style CLR79.
(1)
Revison: 14-Jun-16
Document Number: 40159
6
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR65
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09FAILURE RATE
LEVEL (%/1000 h)
L
2.0
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/09-XXXX
MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
75 VDC AT +85 °C; 50 VDC AT +125 °C
3.5
T1
20
8149
8354
1
2
2.5
650
-16
+5
+6
3.5
T1
10
8150
8355
1
2
2.5
650
-16
+5
+6
3.5
T1
5
8151
8356
1
2
2.5
650
-16
+5
+6
6.8
T1
20
8152
8357
1
2
4.1
300
-20
+8
+9
6.8
T1
10
8153
8358
1
2
4.1
300
-20
+8
+9
6.8
T1
5
8154
8359
1
2
4.1
300
-20
+8
+9
15
T2
20
8155
8360
1
5
7.5
150
-16
+8
+9
15
T2
10
8156
8361
1
5
7.5
150
-16
+8
+9
15
T2
5
8157
8362
1
5
7.4
150
-16
+8
+9
33
T2
20
8158
8363
1
10
17.5
90
-24
+10.5
+15
33
T2
10
8159
8364
1
10
17.5
90
-24
+10.5
+15
33
T2
5
8160
8365
1
10
17.5
90
-24
+10.5
+15
40
T3
20
8161
8366
2
12
15.2
60
-16
+10.5
+12
40
T3
10
8162
8367
2
12
15.2
60
-16
+10.5
+12
40
T3
5
8163
8368
2
12
15.2
60
-16
+10.5
+12
56
T3
20
8164
8369
2
17
26
60
-28
+10.5
+15
56
T3
10
8165
8370
2
17
26
60
-28
+10.5
+15
56
T3
5
8166
8371
2
17
26
60
-28
+10.5
+15
110
T4
20
8167
8372
9
36
25.7
29
-35
+20
+20
110
T4
10
8168
8373
9
36
25.7
29
-35
+20
+20
100 VDC AT +85 °C; 65 VDC AT +125 °C
2.5
T1
20
8169
8374
1
2
5
950
-16
+7
+8
2.5
T1
10
8170
8375
1
2
5
950
-16
+7
+8
2.5
T1
5
8171
8376
1
2
5
950
-16
+7
+8
4.7
T1
20
8172
8377
1
2
3.6
500
-16
+7
+8
4.7
T1
10
8173
8378
1
2
3.6
500
-16
+7
+8
4.7
T1
5
8174
8379
1
2
3.6
500
-16
+7
+8
11
T2
20
8175
8380
1
4
5
200
-16
+7
+8
11
T2
10
8176
8381
1
4
5
200
-16
+7
+8
11
T2
5
8177
8382
1
4
5
200
-16
+7
+8
22
T2
20
8178
8383
1
9
11.8
100
-16
+7
+8
22
T2
10
8179
8384
1
9
11.8
100
-16
+7
+8
22
T2
5
8180
8385
1
9
11.8
100
-16
+7
+8
30
T3
20
8181
8386
2
12
9.1
80
-16
+7
+8
30
T3
10
8182
8387
2
12
9.1
80
-16
+7
+8
30
T3
5
8183
8388
2
12
9.1
80
-16
+7
+8
43
T3
20
8184
8389
2
17
19.7
70
-20
+7
+8
43
T3
10
8185
8390
2
17
19.7
70
-20
+7
+8
43
T3
5
8186
8391
2
17
19.7
70
-20
+7
+8
86
T4
20
8187
8392
9
36
20.7
30
-25
+15
+15
86
T4
10
8188
8393
9
36
20.7
30
-25
+15
+15
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79.
Revison: 14-Jun-16
Document Number: 40159
7
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR65
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/09FAILURE RATE
LEVEL (%/1000 h)
L
2.0
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/09-XXXX
MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
125 VDC AT +85 °C; 85 VDC AT +125 °C
1.7
T1
20
8189
8394
1
2
7
1250
-16
+7
+8
1.7
T1
10
8190
8395
1
2
7
1250
-16
+7
+8
1.7
T1
5
8191
8396
1
2
7
1250
-16
+7
+8
3.6
T1
20
8192
8397
1
2
4.1
600
-16
+7
+8
3.6
T1
10
8193
8398
1
2
4.1
600
-16
+7
+8
3.6
T1
5
8194
8399
1
2
4.1
600
-16
+7
+8
9.0
T2
20
8195
8400
1
5
10.2
240
-16
+7
+8
9.0
T2
10
8196
8401
1
5
10.2
240
-16
+7
+8
9.0
T2
5
8197
8402
1
5
10.2
240
-16
+7
+8
25
T3
20
8204
8409
2
13
19
93
-16
+7
+8
25
T3
10
8205
8410
2
13
19
93
-16
+7
+8
25
T3
5
9026
9029
2
13
19
93
-16
+7
+8
56
T4
20
9027
9030
10
40
17.5
32
-25
+15
+15
56
T4
10
9028
9031
10
40
17.5
32
-25
+15
+15
Note
(1) Style CLR65 is inactive for new military design. For new design use style CLR79.
STANDARD RATINGS/EXTENDED RATINGS: CLR69
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21FAILURE RATE
LEVEL (%/1000 h)
L
2.0
M
1.0
0089
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/21-XXXX
MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
-64
+13
+16
6 VDC AT +85 °C; 4 VDC AT +125 °C
220
T1
20
0001
2
9
50
36
220
T1
10
0002
0090
2
9
50
36
-64
+13
+16
820
T2
20
0003
0091
3
14
155
18
-88
+16
+20
820
T2
10
0004
0092
3
14
155
18
-88
+16
+20
1500
T3
20
0005
0093
5
20
172
18
-90
+20
+25
1500
T3
10
0006
0094
5
20
172
18
-90
+20
+25
2200
T4
20
0007
0095
6
24
170
13
-90
+25
+30
2200
T4
10
0008
0096
6
24
170
13
-90
+25
+30
8 VDC AT +85 °C; 5 VDC AT +125 °C
180
T1
20
0009
0097
2
9
41
45
-60
+13
+16
180
T1
10
0010
0098
2
9
41
45
-60
+13
+16
680
T2
20
0011
0099
3
14
130
22
-83
+16
+20
680
T2
10
0012
0100
3
14
130
22
-83
+16
+20
1500
T3
20
0013
0101
5
20
170
18
-90
+20
+25
1500
T3
10
0014
0102
5
20
170
18
-90
+20
+25
1800
T4
20
0015
0103
7
25
138
14
-90
+25
+30
1800
T4
10
0016
0104
7
25
138
14
-90
+25
+30
Note
(1) Style CLR69 is inactive for new military design. For new design use style CLR81.
Revison: 14-Jun-16
Document Number: 40159
8
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR69
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21FAILURE RATE
LEVEL (%/1000 h)
L
2.0
150
150
560
560
1200
1200
1500
1500
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0017
0018
0019
0020
0021
0022
0023
0024
100
100
390
390
820
820
1000
1000
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0025
0026
0027
0028
0029
0030
0031
0032
68
68
270
270
560
560
680
680
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0033
0034
0035
0036
0037
0038
0039
0040
56
56
220
220
470
470
560
560
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0041
0042
0043
0044
0045
0046
0047
0048
33
33
120
120
270
270
330
330
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0049
0050
0051
0052
0053
0054
0055
0056
27
27
100
100
220
220
270
270
T1
T1
T2
T2
T3
T3
T4
T4
20
10
20
10
20
10
20
10
0057
0058
0059
0060
0061
0062
0063
0064
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/21-XXXX
MAX. DF
AT +25 °C
(%)
10 VDC AT +85 °C; 7 VDC AT +125 °C
0105
2
9
34
0106
2
9
34
0107
3
16
106
0108
3
16
106
0109
5
20
137
0110
5
20
137
0111
7
25
114
0112
7
25
114
15 VDC AT +85 °C; 10 VDC AT +125 °C
0113
2
9
30
0114
2
9
30
0115
3
16
74
0116
3
16
74
0117
6
24
111
0118
6
24
111
0119
8
32
92
0120
8
32
92
25 VDC AT +85 °C; 15 VDC AT +125 °C
0121
2
9
22
0122
2
9
22
0123
3
16
55
0124
3
16
55
0125
7
28
76
0126
7
28
76
0127
8
32
63
0128
8
32
63
30 VDC AT +85 °C; 20 VDC AT +125 °C
0129
2
9
22
0130
2
9
22
0131
3
16
42
0132
3
16
42
0133
8
32
64
0134
8
32
64
0135
9
36
55
0136
9
36
55
50 VDC AT +85 °C; 30 VDC AT +125 °C
0137
2
9
12.3
0138
2
9
12.3
0139
4
24
22.5
0140
4
24
22.5
0141
8
32
37
0142
8
32
37
0143
9
36
38
0144
9
36
38
60 VDC AT +85 °C; 40 VDC AT +125 °C
0145
3
12
10.2
0146
3
12
10.2
0147
4
20
19
0148
4
20
19
0149
8
32
30
0150
8
32
30
0151
9
36
27
0152
9
36
27
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
54
54
27
27
18
18
15
15
-55
-55
-77
-77
-88
-88
-88
-88
+13
+13
+16
+16
+20
+20
+25
+25
+16
+16
+20
+20
+25
+25
+30
+30
72
72
31
31
22
22
17
17
-44
-44
-66
-66
-77
-77
-77
-77
+13
+13
+16
+16
+20
+20
+25
+25
++16
+16
+20
+20
+25
+25
+30
+30
90
90
33
33
24
24
19
19
-40
-40
-62
-62
-72
-72
-72
-72
+12
+12
+13
+13
+20
+20
+25
+25
+15
+15
+16
+16
+25
+25
+30
+30
100
100
36
36
25
25
20
20
-38
-38
-60
-60
-65
-65
-65
-65
+12
+12
+13
+13
+20
+20
+25
+25
+15
+15
+16
+16
+25
+25
+30
+30
135
135
49
49
29
29
22
22
-29
-29
-42
-42
-46
-46
-46
-46
+10
+10
+12
+12
+20
+20
+25
+25
+12
+12
+15
+15
+25
+25
+30
+30
144
144
54
54
29
29
23
23
-24
-24
-36
-36
-40
-40
-45
-45
+10
+10
+12
+12
+16
+16
+20
+20
+12
+12
+15
+15
+20
+20
+25
+25
Note
Style CLR69 is inactive for new military design. For new design use style CLR81.
(1)
Revison: 14-Jun-16
Document Number: 40159
9
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
M39006/09, M39006/21
www.vishay.com
Vishay
STANDARD RATINGS/EXTENDED RATINGS: CLR69
CAPACITANCE
(μF)
CASE
CODE
CAP.
TOL.
(± %)
PART NO.
M39006/21FAILURE RATE
LEVEL (%/1000 h)
L
2.0
M
1.0
(1),
MAX. DCL (μA)
AT
+25 °C
+85 °C
+125 °C
M39006/21-XXXX
MAX. DF
AT +25 °C
(%)
MAX. IMP.
AT -55 °C
()
MAX. CAPACITANCE
CHANGE (%) AT
-55 °C
+85 °C
+125 °C
75 VDC AT +85 °C; 50 VDC AT +125 °C
22
T1
20
0065
0153
3
12
8.5
157
-19
+10
+12
22
T1
10
0066
0154
3
12
8.5
157
-19
+10
+12
82
T2
20
0067
0155
4
24
15.2
63
-30
+12
+15
82
T2
10
0068
0156
4
24
15.2
63
-30
+12
+15
180
T3
20
0069
0157
9
36
24.4
30
-35
+16
+20
180
T3
10
0070
0158
9
36
24.4
30
-35
+16
+20
220
T4
20
0071
0159
10
40
37
24
-40
+20
+25
220
T4
10
0072
0160
10
40
37
24
-40
+20
+25
100 VDC AT +85 °C; 65 VDC AT +125 °C
10
T1
20
0073
0161
3
12
4.5
200
-17
+10
+12
10
T1
10
0074
0162
3
12
4.5
200
-17
+10
+12
39
T2
20
0075
0163
5
24
10.4
80
-20
+12
+15
39
T2
10
0076
0164
5
24
10.4
80
-20
+12
+15
68
T3
20
0077
0165
10
40
11.3
40
-30
+14
+16
68
T3
10
0078
0166
10
40
11.3
40
-30
+14
+16
120
T4
20
0079
0167
12
48
25
30
-35
+15
+17
120
T4
10
0080
0168
12
48
25
30
-35
+15
+17
6
300
-14
+10
+12
125 VDC AT +85 °C; 85 VDC AT +125 °C
6.8
T1
20
0081
0169
3
12
6.8
T1
10
0082
0170
3
12
6
300
-14
+10
+12
27
T2
20
0083
0171
5
24
7.2
90
-18
+12
+15
27
T2
10
0084
0172
5
24
7.2
90
-18
+12
+15
47
T3
20
0085
0173
10
40
7.9
50
-26
+14
+16
47
T3
10
0086
0174
10
40
7.9
50
-26
+14
+16
82
T4
20
0087
0175
12
48
17.4
32
-30
+15
+17
82
T4
10
0088
0176
12
48
17.4
32
-30
+15
+17
Note
(1) Style CLR69 is inactive for new military design. For new design use style CLR81.
VOLTAGE DERATING WITH TEMPERATURE
PERCENT OF RATED VOLTAGE
100
80
60
40
20
0
- 55
Revison: 14-Jun-16
- 35
-5
25
45
65
TEMPERATURE IN °C
85
105
125
Document Number: 40159
10
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free
requirements as per JEDEC JS709A standards. Please note that some Vishay documentation may still make reference
to the IEC 61249-2-21 definition. We confirm that all the products identified as being compliant to IEC 61249-2-21
conform to JEDEC JS709A standards.
Revision: 02-Oct-12
1
Document Number: 91000