D_PU-S.pdf

DC-DC Converter UNIT
PU-S SERIES (1 W UNREGULATED)
FEATURES
•Single in line package
•100% Burned in
•High Efficiency
•Continous short circuit protection
•Internal SMD Technology
•No heatsink required
•UL 94V-0 Package material
•RoHS compliant
•3 Years warranty
OUTPUT SPECIFICATIONS
Voltage Set point Accuracy
INPUT SPECIFICATIONS
+/-2% max
Temperature Coefficient
Input Voltage Range
Input Filter
+/-0.05%/ °C
Protection
100mVp-p max
+/-0.1.2% max
+/-8% max
20% of Full Load
Ripple & Noise (20MHz BW)
Line Regulation1
Load Regulation2
Minimum Load
Efficiency
Isolation Voltage3
Isolation Resistance
Automatic
Short circuit Restart
Isolation Capacitance
Switching Frequency
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
74%-83%
3000 Vdc min
109 ohms min
20pF max
100 KHz min
MTBF4
>2.000,000 Hours
Weight
2.1g Typ
Case Material
Non-Conductive Plastic
Case Size
Conducted Emissions
19.6mm*7.5mm*10.2mm
EN55022 Class A
Radiated Emissions
EN55022 Class A
-40 °C to +85 °C
Storage Temperature
Humidity
Cooling
Fuse Recommended
GENERAL SPECIFICATIONS
Continuous
Short Circuit Protection
+/-10% max
Capacitor Typ
-55 °C to +125 °C
95% max
Free-Air Convection
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED.
[1] Line Regulation is for a 1.0% change in input Voltage.
[2] Load Regulation is for output load current change from 20% to 100%.
[3] 1500Vdc for 10 seconds. 3000Vdc for 3 seconds.
[4] MIL-HDBK-217F @25 °C , Ground Benign
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 07th July 2010
DC-DC Converter UNIT
PU-S SERIES (1 W UNREGULATED)
●SELECTION GUIDE(1) 1W 1000VDC ISOLATION
MODEL
NUMBER
INPUT
VOLTAGE
(VDC)
OUTPUT
VOLTAGE
(VDC)
OUTPUT
CURRENT
(mA)
INPUT[5]
CURRENT(mA)
FULL
LOAD
NO
LOAD
EFF
(%)[6]
ISOLATION
(VDC)
PACKAGE
PUS-0505G1S
5
5
200
256
34
78
3000
G
PUS-0509G1S
5
9
111
253
33
79
3000
G
PUS-0512G1S
5
12
84
253
33
79
3000
G
PUS-0515G1S
5
15
67
251
33
80
3000
G
PUD0505G1S
5
+/-5
+/-100
256
34
78
3000
G
PUD0512G1S
5
+/-12
+/-42
253
33
79
3000
G
PUD0505G1S
5
+/-15
+/-34
251
33
80
3000
G
PUS-1205G1S
12
5
200
108
14
77
3000
G
PUS-1209G1S
12
9
111
105
13
79
3000
G
PUS-1212G1S
12
12
84
105
13
80
3000
G
PUS-1215G1S
12
15
67
103
13
81
3000
G
PUD-1205G1S
12
+/-5
+/-100
106
14
78
3000
G
PUD-1212G1S
12
+/-12
+/-42
105
13
80
3000
G
PUD-1215G1S
12
+/-15
+/-34
103
13
81
3000
G
PUS-2405G1S
24
5
200
54
8
77
3000
G
PUS-2409G1S
24
9
111
53
7
78
3000
G
PUS-2412G1S
24
12
84
53
7
79
3000
G
PUS-2415G1S
24
15
67
52
7
80
3000
G
PUD-2405G1S
24
+/-5
+/-100
53
8
78
3000
G
PUD-2412G1S
24
+/-12
+/-42
53
7
79
3000
G
PUD-2415G1S
24
+/-15
+/-34
53
7
80
3000
G
Note: Other input to output voltages may be available. Please contact factory.
[5] NOMINAL INPUT VOLTAGE.
[6] NOMINAL INPUT VOLTAGE, FULL LOAD.
[6] NOMINAL INPUT VOLTAGE.
[7] NOMINAL INPUT VOLTAGE, FULL LOAD.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0, 07th July 2010
DC-DC Converter UNIT
PU-S SERIES (1 W UNREGULATED)
●MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS
PACKAGE „G“
PIN
SINGLE
DUAL
1
+Vin
+Vin
2
-Vin
-Vin
4
-Vout
-Vout
5
NP
COMMON
6
+Vout
+Vout
●SIMPLIFIED SCHEMATIC
●TYPICAL APPLICATIONS
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (3)
Version 1.0, 07th July 2010
DC-DC Converter UNIT
PU-S SERIES (1 W UNREGULATED)
●TYPICAL PERFORMANCE CURVES
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (4)
Version 1.0, 07th July 2010
DC-DC Converter UNIT
PU-S SERIES (1 W UNREGULATED)
●INPUT FUSE SELECTION GUIDE
Note: Other input to output voltages may be available. Please contact factory.
PU-S SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output capacitance may be
increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 250 KHz is required.
We can offer EMC-filter according to EN55011/22 Class B
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
[10] NOMINAL INPUT VOLTAGE.
[11] NOMINAL INPUT VOLTAGE, FULL LOAD.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (5)