TDK_CXA-0474.pdf

Product Drawing
DC/AC INVERTER UNIT
CXA-0474
TDK Corporation
Corporate Headquarters
13-1,Nihonbashi 1-chome,Chuo-ku,
Tokyo 103, JAPAN
Telephone : 81-3-3278-5111
Nov 21 , 2006
N.Matsuura
Nov 21 , 2006
S.Tsujimura
Nov 21 , 2006
N.Kitajima
CTR-2611-X
Precautionary Notes Regarding the Use of This Inverter
When using this product, give due consideration to the precautionary notes described below and ensure a
safe design. Inappropriate use may result in electric shock, injury or fire.
Warning
● This product is subject to high voltage. Do not touch it while the power is on.
Failing to do so may result in electric shock.
Caution
● This product is designed for the lighting of a Cold Cathode Fluorescent Lamp.
Do not use it with any other load.
● Store this product under the conditions defined in the specification document.
● Do not store this product in an environment where dust, dirt or corrosive gas(salt,acid,base, etc.) is present.
● This product is subject to high voltage. If there is a possibility that the user may touch the product,
provide a proper indication in order to draw the user's attention.
● This product is designed for use with general electronic equipment.
If it is to be used with medical equipment that directly affects human life or for the control of
transportation equipment to which passengers entrust their lives, provide thorough fail-safe measures.
● Avoid using this product under high temperatures or high humidity or in an environment in which
dust, dirt or any corrosive gas (salt,acid,base, etc.) is present.
Also,be careful not to allow the formation of dew condensation. It may result in damage or electric shock.
● If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.),
it is recommended that a fuse be used at the input stage to prevent the generation of
smoke or fire in the event of a malfunction.
Even when the product has a built-in protective circuit (circuit breaker, fuse, etc.),
the circuit may not function properly due to inappropriate operating conditions or power-supply capacity.
It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.)
be provided separately from the built-in circuit.
● Use the product only within the specified input voltage, output power, output voltage
and operating temperature ranges. Exceeding these values may result in damage, etc.
● Provide a measure for the prevention of surge voltage due to lightning, etc.
Abnormal voltage may result in damage, etc.
● To prevent problems arising from short-circuiting of the high-voltage section,
provide appropriate measures to prevent the entry of foreign substances following installation.
● This product is not designed to provide resistance to radiation.
● Ripples could be superimposed on the voltage and the current in the input source connected to the inverter ,
depending on the impedance in the input source, wiring, etc.
When you select an input source, please check waveforms, etc on the final set.
Handling Precautions
● This product uses thin wires. Observe the following precautions and handle it with care so
as not to cause wire breakage. Broken wire may result in damage, etc.
・Do not stack multiple products on top of one another.
・Do not allow the product to come in contact with tools, etc.
● Do not apply excessive stress during installation.
It may cause chipping and cracking,resulting in damage, etc.
● Provide clearance between the high-voltage section of this product and the frame body on which the product
is installed and also the conductor section as per listed on page 2 , [1] ”Outline” .
● Please do not use the product, when dropping it, since there is a possibility of the parts damage.
Please confirm abnormality is not found in the product enough when using it by any chance.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
1
1. Part Name
The part name is CXA-0474.
2. Contents
Item
Attached view
Page
1-1. Outline
[1] section
4
1-2. Connector Configuration
[1] section
5
[2] Absolute Maximum Ratings
[2] section
6
[3] Electrical specifications
[3] section
7
[4] Test Circuit
[4] section
7
[5] Reliability Test
[5] section
9
[6] Packaging and marking
[6] section
10
7-1 Test Cond.
[7] section
10
7-2 Std Warranty
[7] section
10
7-3. MTTF
[7] section
10
[1] Outline
[7] Others
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
2
Listed description are subject to change without notice.
●Features●
・This inverter is for two lamps. It has Dimming function(PWM System) and Remote function.
・This product has shutdown function.
It prevents from keeping generating the high voltage when the lamps open.
・With lamp failure detector.
Normal Operation : CN1-8=0V
Some Lamps Open : CN1-8=5V
・Select the way of dimming (between CN1-6 and CN1-7)
1. Insert a potentiometer (0-10kΩ)
2. Apply the voltage (0-2.5V)
・The high-voltage area (terminals and patterns) is coated with silicone so as to avoid the defects caused by dust.
・This product is conformity to RoHS directive.(※)
(※)Conformity to RoHS Directive:This means that, in conformity with EU Directive 2002/95/EC,
lead, cadmium, hexavalent chromium, and specific bromine-based flame retardants, PBB
and PBDE, have not been used,except for exempted applications.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
3
[1] Outline
1-1. Outline
TOP VIEW
Label (Examlpe)
TDK part No, Date code, Country of origin
114±0.5
82±0.3
(22)
2-φ2.5±0.2
CXA-0474
6Y17
MADE IN JAPAN
③
(5)
1
15±0.3
25±0.5
5±0.5
(10)
②
①
SILICONE
SIDE VIEW
(1.0)
(10)
High Voltage generation area 62mm
*Please secure the air clearance of 3mm or more from the high voltage generation area up and down and right and left.
Please refer to Note1-3. for details.
BOTTOM VIEW
Unit:mm
Product name
Quantity
Remark
Mates With
①
PCB
Material
Composite (CEM-3)
1
UL94V-0 t=1.0
-
②
CN01
53261-0871
1
(MOLEX)
51021-0800
③
CN02
SM03(7-D1)B-BHS-1-TB(LF)(SN)
1
(JST)
BHR-04VS-1
Symbols
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
4
1-2. Connector Configuration
Input side CN1
Pin No.
CN01-1
CN01-2
CN01-3
CN01-4
Output side CN2
Symbols
Ratings
Notes
Vin
11.4~12.6V
Input Voltage
GND
0V
GND
Pin No.
Symbols
Ratings
Notes
CN02-1 CFL HOT
600Vrms
Out put1
CN02-2 CFL HOT
600Vrms
Out put2
(2V)
Out Put1,2
RETURN
CN02-3
CN01-5
Vrmt
0V/2.5V~Vin
Remote terminal
0~0.4V:OFF
2.5V~ Vin V:ON
open:ON
CN01-6
Rbr1/Vbr
0~ 2.5V
/0~10kΩ
Control terminal 1
CN01-7
Rbr2
0~ 10kΩ
Control terminal 2
CN01-8
Vst
(Out Put)
0V/5V
Alarm output
5V when lamps are
open
NC
CN02-4 CFL COLD
-
-
Note1-1. Marking of TDK part No, Date code, Country of origin.
1) TDK part No., Date code, Country of origin, is marked on the transformer.
2) Date code example. (ex. Nov.17 . 2006)
6
Y
1
7
Two digits of production day.
One digit of production month. (Oct. : X, Nov. : Y, Dec. : Z).
Last digit of production year.
3) Country of origin code example. (ex. MADE IN JAPAN. MADE IN CHINA).
Note1-2. For circuit connection, please prefer to test circuit diagram [4].
Note1-3. Please use minimum of 3mm clearance (all directions) between inverter high voltage area and any conductors.
Please refer to mechanical drawing for marking of high voltage area.
Note1-4. Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at
the output connector would be less than the actual value.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
5
Note1-5. If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily specially at
lower ambient temperature. Please review mounting instruction to avoid any abnormal operation due to
coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
fig1.High Voltage Code
NG
OK
LCD MODULE
LCD MODULE
CN2
CN2
Note1-6. Please check your lamp characteristic for minimum operational current and set the limit point in your design to
avoid flickering and/or abnormal operation.
Note1-7. For proper operation of circuit protection (fuse or IC PROTECTOR),Please use minimum of 2A capacity for input
power supply.
Note1-8. For proper operation: Don't connect the out put VLOW(CN2-4) terminal to the input GND(CN1-3,4).
[2] Absolute Maximum Ratings
Items
Symbols
Specification
Unit
Notes
Vin
0~ 14
Vrmt
-1~ Vin+1
Vbr
0~ 16
V
-
Output Power
RL
120
kΩ
-
Operating Temp. range
Ta
-10~ 70
℃
-
Storage Temp. range
Ts
-30~ 85
℃
-
Humidity range
RH
95
%RH
A maximum wet ball temperature is 39°C
Input Voltage
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
6
[3] Electrical specifications
Conditions
Item
Symbol
Output Current
(Brightness max.)
Specifications
Vin(V)
Vrmt(V)
Rbr(kΩ)/
Vbr(V)
lo1/2
12±0.6
5±0.25
10 / 2.5
-10~ 70
Output Current
(Brightness min.)
lo1/2
12±0.6
5±0.25
0/0
-10~ 70
Input Current1
lin1
12±0.6
5±0.25
10 / 2.5
-10~ 70
Input Current3
lin2
12±0.6
0±0.25
10 / 2.5
-10~ 70
Frequency
F1
12±0.6
5±0.25
10 / 2.5
-10~ 70
Frequency
F2
12±0.6
5±0.25
0/0
-10~ 70
Open Circuit Voltage
Vopen
11.4 min.
5±0.25
10 / 2.5
-10~ 70
12±0.6
5±0.25
10 / 2.5
-10~ 70
12±0.6
5±0.25
10 / 2.5
-10~ 70
12±0.6
5±0.25
10 / 2.5
-10~ 70
Vst
Warning Output
Ta(℃ )
RL1(KΩ)
RL2(KΩ)
110
110
110
110
110
110
110
110
110
110
110
110
∞
∞
110
∞
∞
110
110
110
Unit
MIN.
TYP.
MAX.
4.5
5.0
5.5
1.5
2.5
3.5
-
0.6
1.0
A
-
-
1
mA
63.5
67.5
72.0
kHz
241
255
268
Hz
1.75
1.85
1.95
kVrms
4.5
5.0
5.5
4.5
5.0
5.5
-
0
0.5
mArms
V
[4] Test Circuit
F
Vin
10.8~ 13.2V
Vrmt
5V
Vbr
0~ 2.5V
A Iin
-
CN1-1
CN1-2
V
-
b
F2
CN2-1
CN1-3
CN1-4
a
V
-
1000:1
PROBE
F
SW1
CN1-5
CN2-2
b
Rbr
0~ 10kΩ(0.025W min)
SW
4
RL2
T112,13
Io2
a
V
-
SW
3
T1
T1-2
SW2
V
-
Vst
CN1-6
IC2-1
CN1-7
CN2-4
IC2
Vopen V
~
A
~
RL
1
A
~
Io1
SW
5
RL1,2:Load resistance (7W MIN.)
CN1-8
*For the number of the component's positon, please refer to Outline diagram [1].
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
7
Note.4-1.SW1(ON/OFF) Operation is as following;
SW1
Operation of unit
a
Operation
b
Non operation
Open
Operation
Note.4-2.SW2(ON/OFF) Operation is as following;
SW2
Operation of unit
a
*Voltage dimming
Vbr=0~2.5V
b
*Variable resistance dimming
VR=0~10k
Ω
*Vbr=2.5V:brightness MAX.
Rbr=10kΩ:brightness MAX.
Note4-3.Safety Function
Load Condition
Alarm Signal
(CN1-6)*1
Shutdown Operation*2
Normal
Operation
0.5V max.
Normal
1 Lamp Open
4.75~5.25V
Normal
2 Lamps Open
4.75~5.25V
Shutdown
*1 In test circuit[4] ,if CN2 or CN3 opens,
then the warning sig nal will be activated (+5V).
*2 If the inverter detects o pen circuit all of the lamps
for more than 3 secon ds it will shut down.
V
Digital Multiple Meter(ADVA NTEST R6451A or equivalent)
A
DC Current Meter(ADVANTEST R6451A or equivalent)
F
Frequency Countor(ADVANTE ST R6452A or equivalent)
V
~
True RMS Meter(KEITHLEY 2001 or equivalent.)
A
High Frequency Current Meter(KEITHLEY 2001 or equivalent)
~
1000:1
High Voltage Probe (Tektronix P3000 or equivalent)
Connection diagram of LCD module (Reference)
LCD module
DC-AC inverter
A
VLOW
lamp
VHIGH
VHIGH
lamp
*Connect the High Frequency Current Meter to the Low-Voltage (VLOW) side.
Remote terminal circuit (Reference)
CN1-1,2
Vin
130kΩ
CN1-5
Vrmt
10kΩ
10kΩ
20kΩ
10kΩ
IC1
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
8
[5] Reliability Test
Following test items are assured.
Items
Conditions
Judgement
Low Temp.Non
operational
-30℃ 500h
Low Temp.operational
-10℃ 500h
High Temp.Non
operational
85℃ 500h
High Temp.operational
70℃ 500h
Heat shock
-30℃⇔ 85℃
30min.Each 100 Cycles
Humidity
(Non operational)
60℃ 95%RH 500h
Vibration
10~57Hz Amplitude
2
2
58~500Hz19.6m/s
Sweep:11min
120min each axis X,Y,Z
Shock
980m/s2
11ms Harf-sine pulse
5 time each axis ±X,Y,Z
Electrical and apperrance should be in the spec.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
9
[6] Packing and Marking
A shipping box is packaged to avoid from water or damage. Following items are printed on the box.
6-1. TDK part No.
CXA-0474
6-2. Manufacture
TDK
6-3. Customer part No.
6-4. QTY.
6-5. Inspection No.
6-6. Country of origin
Anti static bag
10pcs / box
10pcs/Inner box × 10
=100pcs/Outer carton
Inner box
Marking
TDK Part No.
Manufacture
Customer Part No.
QTY.
Inspection No.
Countory of origin
[7] Others
7-1. Test cond.
A normal test condition :Temperature (20±15°C), Humidity (65±20%RH).
Outer carton
7-2. Std warrantry
One year after shipment.This covers any defects in material or workmanship. Defective units will be
replaces at no charge.
7-3. MTTF
MTTF which calculated according to MIL-HDBK-217-F is as follows.
TEMPERATURES
25℃
MTTF
1400000 hours or more
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0474
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2611-X
10