PS_PS-DA0201-137.pdf

DC-AC INVERTER UNIT
PS-DA0201-137(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual lamps.
Optimized for Chi Mei: G121X1-L01 and G150X1-L01
APPLICABLE LCD:
6.4 to 18 inches double lamps
Lamp voltage 580 Vrms
Lamp current 2 x 8 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open lamp detection
Wide dimming range
High efficiency
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-30°C ~ +70°C
-40°C ~ +85°C
95 %RH max
160 x 25 x 10 mm
Pin 1
Pin 1
Pin 1
Unit : mm
Weight :24,2 (g) typ.
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
Vrm t
CN 1-3
Vbr
CN 1-4
CN 1-5
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-K
SM02(8.0)B-BHS-1-TB
Ratings
12 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
0 ~ 2.5 Vdc
N.C.
Note
t=1m m
JST or equal
JST or equal
Output side CN2 + CN3:
Pin No.
Symbols
Ratings
VHIGH
580 Vrm s (8 m Arm s )
CN 2-1
N.C.
CN 2-2
VLOW
GND
CN 2-3
-
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0.1, 21st May 2014
DC-AC INVERTER UNIT
PS-DA0201-137(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Note 1 :
Specification
Vin (V)
Vbr (V)
Tu (°C)
Iout
Iout
Iin
F
Vopen
12±1.2
12±0.6
12±1.2
12±1.2
11.4
0.0
2.5
0.0
0.0
0.0
-30
-30
-30
-30
-30
Ts d
12±1.2
0.0
-30 ~ +70
~ +70
~ +70
~ +70
~ +70
~ +70
Unit
Note
8.5
1.2
55
1.900
m Arm s
%
Adc
kHz
Vrm s
Duty 100%
-
s ec
wit hout load
Min.
Typ.
Max.
7.5
45
1.300
8.0
20
0.88
50
1.500
-
1.0
Dut y M in
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)