PS_PS-DA0211-03.pdf

DC-AC INVERTER UNIT
PS-DA0211-03(S) (11 W DUAL OUTPUTS)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 650 Vrms
Lamp Current 2 x 6.0 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 24 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
140 x 24 x 14mm
3.2Ø X2
PIN 1
PIN 1
Q2
C3
C6
R21
C8
R15
R18
C12
R4
? ?
CAUTION
C10
Q11
R8
R6
R9
L2
T1
CN3
C4
C5
R2
CN1
Q12
R20
R3
? ?
R7
!
R5
?
CAUTION
CN2
1
F1
D4
D3
DA0211-
D1
CN1
D2
1
Q1
REV:1.0
A0
!
T2
C2
CN3
?
LxWxH
R1
DIMENSIONS :
-10°C ~ +60°C
-40°C ~ +85°C
95 %RH max
1
C1
CN2
L1
PIN 1
Unit : mm
Weight :39,8 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
Vbr
CN 1-3
GND
CN 1-4
CN 1-5
Vrmt
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1mm
JST or equal
JST or equal
Output side CN2 & CN3:
Pin No.
Symbols
Ratings
Vhigh
650 Vrms (6.0 mArms)
CN 2/3-1
N.C.
CN 2/3-2
Vlow
(GND)
CN 2/3-3
Ratings
21,6 ~ 26,4Vdc
0 ~ 4.2 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.2,1, 2nd September 2010
DC-AC INVERTER UNIT
PS-DA0211-03(S) (11 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Iout
Output Current
Iout
Output Current
Iin
Input Current
F
Frequency
Open Circuit Voltage Vopen
Tsd
No load Shutdown
Int. PWM
Dimming Function
Note 1 :
Note 2:
Vin (V) Vrmt (V) Tu (°C)
Min.
Typ.
Max.
24±1.2
24±0.6
24±1.2
24±1.2
21.6
24±1.2
-
5.0
2.5
44.5
1.300
1.0
2.5
6.0
3.0
0.84
52
1.500
3.0
6.5
3.5
1.23
59.5
1.700
3.5
5±0.25
5±0.25
5±0.25
5±0.25
5±0.25
5±0.25
5±0.25
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
mArms
Vbr = 0 Vdc
Vbr = 4.2 Vdc
wit hout load
Vbr.4.2Vdc²
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Dimming function: Brightness max. @ Vbr = 0 Vdc, Brightness min. @ Vbr. = 4,2 Vdc.
TEST CIRCUIT :
Vin
12 V
Specification
A
F
Iin
1000:1
PROBE
F
CN1-1
Vopen V
~
SW3
V
SW 1
Operation of unit
a
Operation
b
Non operation
CN2-1
CN1-2
CN1-3
CL1
RL1
A
~
T1
CN2-2
Vbr
0 ~ 4.2 Vdc
SW4
Iout1
SW5
CN1-4
CN3-1
Vrmt
0 / 5 Vdc
V
b
CL2
RL2
a
SW1
CN1-5
CN3-2
SW6
A
~
Iout2
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.2,1, 2nd September 2010