DC-AC INVERTER UNIT
PS-DA0144-01(S) (5W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamp.
APPLICABLE LCD:
6,4 to 12 inches single lamp type
Lamp Voltage 690 Vrms
Lamp Current 5 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 5 Vdc)
FEATURES :
Remote ON/OFF
RoHS compliant (S)
Wide Dimming Function with intern PWM controller
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxW xH
-10°C ~ +50°C
-20°C ~ +85°C
95 %RH max
95.5 x 30 x 9,5 mm
Unit : mm
Weight :20 (g) typ.
Components
No.
1
2
3
Note: Please use plastic screw in case of a non-insulating mounting base!
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No. Symbols
CN 1-1
Vin
CN 1-2
CN 1-3
GND
CN 1-4
Vrm t
CN 1-5
Vbr
CN 1-6
Qty.
1
1
1
Ratings
4.75 ~ 5.25V
0V
Material
UL94V-0 (CEM-3)
53261-0690
SM02(8.0)B-BHS-1-TB
Output side CN2:
Pin No.
Symbols
Vlow
CN 2-1
N.C.
CN 2-2
Vhigh
CN 2-3
Note
t=1.0m m
MOLEX
JST
Ratings
2V
690Vrms (5mArms)
0~0.4V=OFF / 2.5V~Vin=ON
0 ~ 5V
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.1.2, 31th August 2010
DC-AC INVERTER UNIT
PS-DA0144-01(S) (5W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F1
Vopen
Tsd
Note 1 :
Note 2:
Note 3:
Vin (V)
5±0.05
5±0.5
5±0.5
5±0.5
4,75
5±0.5
Conditions
Vrmt (V)
0
5.0
0
0
0
0
Tu (°C)
-10~+50
-10~+50
-10~+50
-10~+50
-10~+50
-10~+50
Specification
Min.
Typ.
Max.
4.5
5.0
5.5
20
0.97
1.30
40
50
60
1.500
1.700
2000
1.0
-
Unit
Note
mArms
%
Adc
kHz
Vrms
sec.
Duty 100%
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Open circuit on all lamps for more than 1 sec.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)