DC-AC INVERTER UNIT PS-DA0404-01(S) (24 W QUAD OUTPUTS) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC to AC Inverter is developed for quad lamps. APPLICABLE LCD: 6.4 to 15 inches quad lamp type Lamp Voltage 714 Vrms Lamp Current 4 x 7 mArms Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 0°C ~ +50°C -20°C ~ +85°C 95 %RH max 160 x 27 x 13 mm Pin 1 Pin 1 Unit : mm Weight :38,4 (g) typ. Pin 1 Pin 1 Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 ~ CN5 Input side CN1: Pin No. Symbols Vin CN 1-1 GND CN 1-2 Vrm t CN 1-3 Vbr CN 1-4 CN 1-5 Qty. 1 1 4 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-K SM02B-BHSS-TB Note t=1m m JST or equal JST or equal Output side CN2 ~ CN5 Pin No. CN 2-1 CN 2-2 Ratings 10,8 ~ 13,2 Vdc Symbols Vhigh Vlow Ratings 714 Vrm s (7 m Arm s ) (GND) 0 ~ 0.4 = OFF / 4.5 ~ Vin = ON 0 ~ 3.3 Vdc N.C. Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.7.3, 07th September 2010 DC-AC INVERTER UNIT PS-DA0404-01(S) (24 W QUAD OUTPUTS) (PRELIMINARY INFORMATION) ELECTRICAL CHARACTERISTICS : Parameters Symbols Output Current Output Current Input Current Frequency Open Circuit Voltage Iout Iout Iin F Vopen Ts d No load Shutdown Note 1 : Conditions Vrmt Vin (V) Tu (°C) (V) 12±1.2 5±0.25 0 ~ +50 12±0.6 5±0.25 0 ~ +50 12±1.2 5±0.25 0 ~ +50 12±1.2 5±0.25 0 ~ +50 11.4 5±0.25 0 ~ +50 12±1.2 Specification Unit Note Min. Typ. Max. 6.3 1.5 50 1.300 7.0 2.0 1.6 55 1.500 7.5 1.5 2.0 65 - m Arm s m Arm s Adc kHz Vrm s 1.0 - - s ec 5±0.25 0 ~ +50 V br = 0 V dc V br = 3.3 V dc wit hout load Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. TEST CIRCUIT : F Vin 12 V Iin A 1000:1 PROBE F CN2-1 CN1-1 Vopen V ~ SW3 CL1 RL1 V CN1-2 CN2-2 A Iout ~ 1 SW4 SW 1 Operation of unit a Operation b Non operation SW3 CN3-1 Vrmt 0 / 5 Vdc V b SW1 CN1-3 A ~ CL1 Iout 1 A ~ CL1 Iout 1 A ~ CL1 Iout 1 RL1 T1 a CN3-2 SW4 SW3 CN4-1 CN1-4 Vbr 0 ~ 3.3 Vdc RL1 SW4 CN4-2 SW3 CN5-1 N.C. RL1 CN1-5 CN5-2 SW4 Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.7.3, 07th September 2010