Downloads for PC Mount Split Pack™ Power Transformers (FS48-400)

P OWE R T RAN S FO R M E R
P C M O U N T : SPLIT PACK
FS48-400
Description:
The FS48-400 is a dual primary and dual secondary, split bobbin design which
operates with either a parallel input of 115V or a series input of 230V. The output
voltage will be either 48.0V with a center-tap under a 0.4A load with the
secondaries wired in series, or 24.0V under a 0.8A load with the secondaries
wired in parallel. The split bobbin design eliminates the need for costly
electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 20.0VA
2. Primary:
Series: 230V; Parallel: 115V
3. Secondary: Series: 48.0V CT@ 0.4A; Parallel: 24.0V @ 0.8A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
W
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
This model is also available in Class 3, UL 5085-3 (1585) version as FS48-400-C2
Dimensions:
H
W
1.437
1.875
Weight: 0.80 lbs
H
Units in inches.
L
2.25
A
0.300
B
0.400
C
1.600
D
0.041
E
0.020
F
0.234
1
PARALLEL
115/230V
50/60Hz
4
D
Schematic:
1
3
2
5
2
3
6
7
4
8
SERIES
1
115/230V
50/60Hz
F
2
3
A
1
115/230V
50/60Hz
4
A
5
2
3
8
B
4
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571