PS_PS-M05D05S6-NJ4L-019.pdf

DC-AC INVERTER UNIT
PS-M05D05S6-NJ4L-019(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for NEC: NL10276BC24-13.
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 570 Vrms
Lamp Current 5 mArms
Lamp Start Up Voltage 1.450 Vrms (Vin : 5 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM-Dimming Function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
82 ± 0.3
13 ± 0.5
PS-MXXDXX-NJX
29/01/2004
MADE IN
GERMANY
CN1-1
CN2
(2)
CN1
15 ± 0.3
22,5 ± 0.5
105 x 22,5 x 10mm
105 ± 0.5
5 ± 0.5
DIMENSIONS :
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
CN2-1
CN1-5
10.0MAX
CN2-4
3
2 - Ø2.5 ± 0.2
(for M2 screws)
2
(2)
Unit : mm
Weight :20 (g) typ.
1
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
CN 1-3 Ext. PWM
N.C.
CN 1-4
CN 1-5
Vrm t
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM03(4.0)B-BHS
Note
t=1.6m m
JST or equal
JST or equal
Output side CN2:
Ratings
5 Vdc
0 ~ 5 Vdc (L activ)
Pin No.
CN 2-1+2
CN 2-3
CN 2-4
Symbols
Vhigh
N.C.
Vlow
Ratings
570 Vrms (5 mArms)
0 Vdc
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.2.1, 12th Mar 2007
DC-AC INVERTER UNIT
PS-M05D05S6-NJ4L-019(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Conditions
Vrmt
Tu (°C)
Vin (V)
(V)
5±0.05 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
4.75
5±0.25 0 ~ +60
Specification
Min.
Typ.
Max.
4.5
4.3
50
1.450
5.0
5.0
1.6
60
-
5.5
5.7
2.5
70
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Dut y 10 0%
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
Note 2 :
TEST CIRCUIT :
F
A
Vin
5V
Iin
1000:1
PROBE
F
CN1-1
Vopen V
~
SW 1
SW3
V
CN2-1
CN1-2
Operation of unit
a
Operation
b
Non operation
SW4
CN1-3
T1
CN2-2
RL2
RL1
Ext. PWM*
0~5V
CL2
A
NC
Vrmt
2.5 Vdc ~ Vin
SW5
a
V
b
CL1
A
~
Iout ~
Iout1
2
CN1-4
CN2-4
SW1
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.2.1, 12th Mar 2007