Download

12W AC-DC Power-Supply PAC12D
●
●
●
●
●
●
●
Enclosed plastic case
85 … 264VAC universal input range
Continuously short circuit protected
Over voltage protected
Isolation class II
4 kVAC isolation
3 years product warranty
Model guide
Type
PAC12D03S
PAC12D05S
PAC12D12S
PAC12D15S
PAC12D24S
Output
voltage
[VDC]
3.3
5.0
12
15
24
Output
voltage
tolerance
[%] typ.
±3
±2
±2
±2
±2
Output current
max.
[mA]
Ripple & noise
up to 20 MHz
max. [mVp-p]
Efficiency typ.
@ full load
[%]
2400
2400
1000
800
500
100
100
100
100
100
74
78
82
82
83
Stand by
consumption
[W] max.
0.3
0.3
0.3
0.3
0.3
Capacitive
load
max.
[µF]
10000
10000
5400
2700
1500
Specifications
Input
Voltage range
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to
output)
Leakage current
Output
Line regulation
Load regulation@10 to 100%
load change
Temperature coefficient
Ripple & noise up to 20MHz
Protection
Short circuit
Over current
Over voltage clamping
General
Switching frequency
Hold up time @ full load
Reliability MTBF
MIL-HDBK-217@ 25 °C
Safety approvals
Safety
85..264 VAC or
120..370 VDC
Power derating see diagram
47…63 Hz
280 mA @ 115 VAC, typ.
190 mA @ 230 VAC, typ.
10 A typ. @ 115 VAC
20 A typ. @ 230 VAC
2 A /250V slow blow
4000 VAC for 1 min.
0.1 mA typ.@Vin 230 VAC
±0.5 %, typ.
±1 %, typ.
± 0.02% / °C
100 mV max.
Continuous, auto recovery
110 %, min. of full load
Z-Diode
100 kHz typ.
120 ms @ 230 VAC. min.
24 ms @ 115 VAC. min.
>300000 h
EN60950, UL60950
Class II
EMI: Conducted & Radiation
(without external filter circuit)
ESD: Electrostatic discharge
EMS: Radiation immunity
EFT: Fast transients on
mainsline
Surge immunity:
(without external filter circuit)
Surge immunity:
(with circuit PIF002B, Fig 2)
Conducted disturbance
immunity
Immunity for power frequency
magnetic field
Immunities of voltage dip,
drop and short interruption
Environmental
Operating ambient
temperature
Case temperature
Storage temperature
Power derating
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Wave soldering temperature
Manual soldering temperature
CE: EN55022 (CISPR22),
class B
RE: EN55022 (CISPR22),
class B
IEC-, EN61000-4-2, air ±8 kV,
contact ± 6 kV, perf. critera B
IEC-, EN61000-4-3, 10 V/m,
perf. criteria A
IEC-, EN61000-4-4, ± 4 kV,
perf. criteria B
IEC, EN61000-4-5,
±2 kV, perf. criteria B
IEC, EN61000-4-5,
±4 kV, ±6 kV, perf. criteria B
IEC-, EN61000-4-6, 10 Vrms,
perf. criteria A
IEC-, EN61000-4-8, 10 A/m,
perf. criteria A
IEC-, EN61000-4-11, 0%..70%,
perf. criteria B
-25 °C to +70 °C
(with power derating)
95°C, max.
-40 °C to +105 °C
See diagram
95 %, non condensing
Free air convection
53.5 x 28.8 x 23.5 mm
60 g
UL94V-0 rated
260°C, 10s, 1.5mm from case
360°C, 5s, 1.5mm from case
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W AC-DC Power-Supply PAC12D
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W AC-DC Power-Supply PAC12D
Typical application circuit
Figure 1
L
F1
PAC12DxxS
R1
L
ϑ
U
N
Model
C1
Cer.
[µF]
1
1
1
1
1
PAC12D03S
PAC12D05S
PAC12D12S
PAC12D15S
PAC12D24S
C1
D1 +Vout
C2
+Vo
R2
-Vout
-Vo
N
C2
[µF]
220
220
120
120
68
F1
slow blow Fuse
R1
NTC
R2
MOV
D1
TVS
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
3.15A / 250V~
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
NTC 5D-9
S10K350
S10K350
S10K350
S10K350
S10K350
SMBJ7.0A
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
C4/5
Y type
[pF]
2200
2200
2200
2200
2200
C6
X type
[µF]
0.15
0.15
0.15
0.15
0.15
L1
[µH]
5
5
5
5
5
L2
CoMo
[mH]
20
20
20
20
20
Application circuit and example for ripple and noise reduction
Figure 2
PAC12D
Input Filter PIF002A
F1
L
+Vout
U
+
C1
C2
D1
-Vout
U
U
N
N
PE
Recommended layout to Figure 2
Suggestions: wire wide >3 mm, safety distance between input and output > 8 mm
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W AC-DC Power-Supply PAC12D
Note:
1. C1 is a ceramic capacitor, it is used to filter high frequency noise. Output filtering capacitor C2 is a electrolytic
capacitor. It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and
current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80 % or above
TVS D1 is a recommended component to protect post-circuits (if converter fails).
2. The Varistor R2 protect the device under surge.
3. Recommended fuse parameter for F1 are 3.15 A / 250 V slow blow. A external input NTC limited the inrush
current. Recommended model is NTC 5D-9. (see figure 1 and table)
4. If common requirement to EMC performance, refer to figure 1.
If higher requirement to EMC performance, refer to figure 2.
C6: X capacitor, recommended values 0.15 μF / 275 V.
C4, C5: Y capacitor, recommended values 2200 pF / 400 V.
L1: serial inductor, recommended inductance is 5 µH.
L2: common mode choke, recommended inductance is about 10 mH…30 mH.
Dimensions
Pin connections
Pin
1
2
3
4
AC In (N)
AC In (L)
+ DC Out
- DC Out
Note
Unit: mm
Pin diameter: 1mm ± 0.10 mm
General tolerances: ± 0.50 mm
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 05.15 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]