303 Connector Block Accessories

Features
■ Convenient test access
■ Rapid fault diagnosis
■ Industry-standard connectors
■ Rugged, long-lasting materials
Central Office Connector Block Accessories
Test Cords
303-1001
This test cord plugs into the test field of the C(G)-303,
C(G)-310, C-377, C-388 and C(G)-390 CO Connectors and
allows single pair identification by tone device or by
grounding. It permits pair shorting, grounding of shorted pairs
and individual tip or ring grounding. It is also used for fast
hook-up to test sets. The 303-1001 is equipped with a test field
plug on one end and two insulated alligator clips on the other
end.
NT8G99AA
This test cord is the same as the 303-1001 except it is
designed expressly for use with the C(G)-391 connector.
303-1013
The cord plugs into the protector module field testing toward
central office or outside plant, is equipped with a plug on one
end, and the other end is free to connect your own plug.
303-1203
This bridging module fits into the protector module sockets that
will allow the 303-1200 test cord listed on this page to be
connected to the protector module field.
303-1200
This patch cord connects to the protector module outside plant
or central office pairs or to the bridging module. They are used to
perform tests on bridging, carrier and special circuits.
303-1213
This test cord is equipped with mini-test clips on one end and
two insulated alligator clips on the other end.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Central Office Connector Block Accessories
Test Cords (Continued)
303-1103
The cord plugs into the protector module field for testing. It is equipped with a bridging module on one end and two insulated alligator
clips on the other end.
Specifications
Product Code
303-1001
NT8G99AA
303-1213
303-1013
303-1203
303-1200
303-1103
Length m (ft.)
0.53 (1.75)
0.53 (1.75)
0.53 (1.75)
6.1 (20)
—
0.91 (3)
1.22 (4)
Conductors
2
2
2
4
4 pins
2 pins
2
Termination
Test field plug/two alligator clips
Test field plug/two alligator clips; for C(G)-391 only
Mini clips/two alligator clips
Module field plug/unterminated
Bridging module (protector module/socket for test cords)
Two-pin protector module-bridging module plug/two alligator clips
Bridging module/two alligator clips
How to Order
Product
Code
303-1001
NT8G99AA
303-1213
303-1013
303-1203
303-1200
303-1103
Part
Number
A0310189
A0350300
A0344522
A0298286
A0312840
A0312839
A0312982
Description
Test Cord
Test Cord
Test Cord
Test Cord
Bridging Module
Patch Cord
Test Cord
Standard
Pack
1
1
1
1
1
1
1
Size
mm (in.)
25.0 x 25.0 x 51.0 (1 x 1 x 2)
25.0 x 25.0 x 51.0 (1 x 1 x 2)
25.0 x 25.0 x 51.0 (1 x 1 x 2)
25.0 x 200 x 51 (1 x 8 x 11)
60 x 20 x 13 (2.38 x 0.75 x 0.5)
220 x 110 x 90 (8.63 x 4.25 x 3.38)
25.0 x 100 x 200 (1 x 4 x 8)
Weight
kg (lb)
0.03 (0.06)
0.03 (0.06)
0.03 (0.06)
0.34 (0.75)
0.01 (0.5)
0.06 (2.0)
0.57 (1.25)
Note: Order by Part Number.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Central Office Connector Block Accessories
Circuit Markers
Bourns® circuit markers are used to indicate Special Safeguarding Measures/Special Service Protection (SSM/SSP) circuits on the
303-family of connectors.
303-1019
The test point insulator button fits into the recesses on the test
field to isolate the pairs from accidental contact by test points
or during testing with a front tap shoe. The buttons are made
of a red plastic material and are designed to snap into place to
cover one test field contact. Not compatible with C(G)-391.
545-1137
The red-colored plastic cap is used to mark and prevent
accidental access to wire-wrap terminals of special circuits. The
cap is designed to fit snugly over a wire-wrap terminal. One is
required for each terminal.
A0321718
A0408552
Test-point insulator button for C(G)-391 only (not shown).
How to Order
Product
Code
303-1019
A0408552
545-1137
Part
Number
A0310190
A0408552
A0321718
Description
Test Point Insulator (except C(G)-391)
Test Point Insulator (C(G)-391 only
Wire-wrap Terminal Cap
Note: Order by Part Number.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Standard
Pack
100
100
100
Size
mm (in.)
25.0 x 80 x 130 (1 x 3 x 5)
25.0 x 80 x 130 (1 x 3 x 5)
25.0 x 80 x 130 (1 x 3 x 5)
Weight
kg (lb)
0.03 (0.06)
0.03 (0.06)
0.03 (0.06)
Central Office Connector Block Accessories
Mounting Bars and Brackets
Bourns provides mounting bars and brackets for various connector types and applications made of heavy gauge steel.
377-1003
Bracket for wall-mounting a single C-377, C-388 or C(G)-390
connector block.
C(G)-303 and C(G)-310 Connector Blocks
Mounting bars are available for 7-, 8-, 9- and 11.5-ft high frames.
Select the proper mounting bar by connector type and frame
height.
How to Order - Brackets
Product
Code
377-1003
Part
Number
A0337661
Description
Mounting Bracket
Standard
Pack
1
Size
mm (in.)
260 x 100 x 80 (10.38 x 4 x 3)
Weight
kg (lb)
1.90 (4.25)
Note: Order by Part Number.
How to Order - Mounting Bars for C(G)-303 and C(G)-310 Connector Blocks
Product
Code
022-1078-115
022-1079-115
022-1052-115
022-1057-115
022-1508-115
022-1121-115
022-1497-115
022-1496-115
Part
Number
A0386865
A0386867
A0386871
A0386875
A0386866
A0386868
A0386872
A0387156
Connector
Type
C-303
C-303
C-303
C-303
C-310
C-310
C-310
C-310
MDF Height
m (ft.)
2.13 (7)
2.44 (8)
2.74 (9)
3.51 (11.5)
2.13 (7)
2.44 (8)
2.74 (9)
3.51 (11.5)
Length
mm (in.)
1651 (65)
1930.4 (76)
2057.4 (81)
3073.4 (121)
1828.8 (72)
2260.6 (89)
2184.4 (86)
3251.2 (128)
Connector
Capacity
3
4
4/5
6
5
5
6
9
Standard
Pack
1
1
1
1
1
1
1
1
Note: Order by Part Number.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Central Office Connector Block Accessories
Universal Connector Mounting Bars
Bourns® Universal Adapter Bars accommodate the compact spacing dimensions of the C(G)-391, C(G)-390, C-388 and C-377
connectors. They are normally used by mounting them on the ends of the transverse arms of the distributing frame at 8 inch centers.
They may also be mounted on existing verticals using the slots provided. All the bars are made of 3.4 mm (0.135 in.) thick x 38 mm
(1.5 in.) wide plated steel. The mounting bar provides electrical conduction when the distributing frame is used to provide a ground
path for the connectors.
How to Order
Product
Code
Part
Number
MDF Height
m (ft.)
Overall Length
mm (in.)
022-3917-115
022-3918-115
022-3919-115
022-3920-115
A0388387
A0359994
A0388388
A0388389
2.13 (7)
2.44 (8)
2.74 (9)
3.51 (11.5)
1676 (66.60)
1956 (77.00)
2362 (93.00)
3114 (122.60)
Note: Order by Part Number.
REV. A 08/09
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Connector Capacity
377/388/390
391
6
7
7
8
8
10
11
12
Standard Pack
1
1
1
1