Download

1W DC-DC Converter P1B-Series
●
●
●
●
●
4 Pin SIL
Low ripple and noise
1000 VDC isolation
Up to 3000 VDC isolation
MTBF > 1.12 MHours
Model selection guide
Typ
P1B3R33R3S
P1B3R305S
P1B3R312S
P1B053R3S
P1B0505S
P1B057R2S
P1B0509S
P1B0512S
P1B0515S
P1B0518S
P1B0524S
P1B123R3S
P1B1205S
P1B127R2S
P1B1209S
P1B1212S
P1B1215S
P1B1218S
P1B1224S
P1B153R3S
P1B1505S
P1B243R3S
P1B2405S
P1B247R2S
P1B2409S
P1B2412S
P1B2415S
P1B2418S
P1B2424S
P1B483R3S
P1B4805S
P1B487R2S
P1B4809S
P1B4812S
P1B4815S
P1B4818S
P1B4824S
Input nominal
voltage
[VDC]
3.3
3.3
3.3
5
5
5
5
5
5
5
5
12
12
12
12
12
12
12
12
15
15
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
Input current
no-load
[mA]
25
30
45
25
25
25
25
25
25
25
25
16
16
16
16
16
16
16
16
10
10
10
10
10
10
10
10
10
10
7
7
7
7
7
7
7
7
Input current
full-load
[mA]
410
415
505
278
267
264
260
257
257
257
257
116
112
110
109
107
107
107
107
93
86
58
56
55
55
54
54
54
54
29
28
27
27
27
27
27
27
Output voltage Output current
Efficiency typ.
[VDC]
[%]
[mA]
3.3
5.0
12.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
305
200
100
305
200
140
111
84
67
56
42
305
200
140
111
84
67
56
42
305
200
305
200
140
111
84
67
56
42
305
200
140
111
84
67
56
42
71
73
72
72
75
76
77
78
78
78
78
72
75
76
77
78
78
78
78
72
78
72
75
76
77
78
78
78
78
72
75
76
76
76
76
76
76
Suffix: “H” for 3kV isolation voltage
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W DC-DC Converter P1B-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage, tested for
1s
Resistance
Capacitance
Output
Voltage accuracy
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Line voltage regulation
Load voltage regulation
Temperature coefficient
Capacitive Load
EMI Specification
Radiated emissions
ESD Specification
RS Specification
Safety
In accordance with
± 10%
Capacitors
General
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
1000 VDC, standard
3000 VDC suffix H
109 Ω
60 pF, typ.
± 3%, max.
100 mVp-p, max.
for 1s, automatic recovery
± 1.2% per 1% of Vin
± 10% @ load 20..100%
± 0.02% / °C
220 µF, max
Cooling
Physical
Dimensions
Weight
Case material
EN55022 Class B
IEC 61000-4-2 Pref.Crit. B
IEC 61000-4-3 Pref.Crit. A
L 12µH
Potting material
Pin soldering temperature
1.5mm distance from body
IEC60950-1 (2001)
EN60950
UL60950
~ 80 kHz, typ.
-40 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
None required
Up to 95%,
non-condensing
nature convection
SIP4
11.68 x 6.00 x 10.16 mm
1.8 g
non-conductive black
plastic, UL94V-0
Epoxy UL94V-0
260°C for 10sec
DC
10..220µF
DC
4.7..
100µF
Load
1. Ripple/Noise measured with 20MHz bandwidth.
2. Tested by minimal Vin and constant resistive load.
3. Measured Input reflected ripple current with a simulated source inductance of 12uH.
4. Operation under no-load conditions will not damage these devices, however they may not meet all listed specifications.
5. For reduce converter’s ripple & noise, it is recommended to add a 4.7μF~100μF capacitor in output end. For EMI performance
improvement, it is recommended to add a 12μH inductor and a 10μF~220μF capacitor in input end.
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
1W DC-DC Converter P1B-Series
Output voltage versus load
Dimensions
Pin connections
7.5 for Vin-48V-types
6.0
11.68
9.65
Pin Standard
Single
1 -V Input
2 +V Input
3 -V Output
4 +V Output
PHI-CON
P1B0505S
1
2
3
4
3.05
0.5
2.54
All dimensions in mm
Tolerance ±0.25 mm
0.5
0.25
1.25
Life Support Policy: HY-LINE does not
authorize the use of any of its products for use
in life support devices or systems without the
express written approval of an officer of the
Company. Life support systems are devices
which support or sustain life, and whose failure
to perform, when properly used in accordance
with instructions for use provided in the
labeling, can be reasonably expected to result
in significant injury to the user. Rev: 08.11 f
0.5
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages