Download

3W DC-DC Converter P3B-Series
●
●
●
●
●
●
●
●
●
Wide 2:1 input range
Full SMD technology
Up to 3500 VDC isolation
MTBF > 1.1 MHours
Continuous short circuit protection
Low profile metal package available
Mobile / battery driven applications
Distributed power networks
Data communications equipments,
Telecommunication instruments
Process / machine control equipments
Model selection guide
Typ
Input voltage range
[VDC]
Output voltage
[VDC]
Single output
P3B1205S3
9...18
P3B1209S3
9...18
P3B1212S3
9...18
P3B1215S3
9...18
P3B1224S3
9...18
P3B2405S3
18...36
P3B2409S3
18...36
P3B2412S3
18...36
P3B2415S3
18...36
P3B2424S3
18...36
P3B4805S3
36...72
P3B4809S3
36...72
P3B4812S3
36...72
P3B4815S3
36...72
P3B4824S3
36...72
Dual output
P3B1205D3
9...18
P3B1209D3
9...18
P3B1212D3
9...18
P3B1215D3
9...18
P3B1224D3
9...18
P3B2405D3
18...36
P3B2409D3
18...36
P3B2412D3
18...36
P3B2415D3
18...36
P3B2424D3
18...36
P3B4805D3
36...72
P3B4809D3
36...72
P3B4812D3
36...72
P3B4815D3
36...72
P3B4824D3
36...72
The output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
Output current
[mA]
Efficiency typ.
[%]
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
600
334
250
200
125
600
334
250
200
125
600
334
250
200
125
76
77
79
79
79
80
80
82
82
80
77
78
80
80
80
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±300
±167
±125
±100
±63
±300
±167
±125
±100
±63
±300
±167
±125
±100
±63
77
78
78
78
78
78
79
80
80
80
78
79
80
80
80
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3B-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
76% to 82%
260 kHz, typ.
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
± 1%, max.
± 1%
60 mVp-p, max.
31.75 x 20.32 x 10.16 mm
16.3 g metal, standard,
14.5 g plastic suffix “P”
Standard, nickel-coated
copper metal
Case material
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
Dimensions
27.94
31.75
0.5
P3B1205D3
PHI-CON
1
12
bottom view
20.32
24
All dimensions in mm
Tolerance ±0.25 mm
0.5
15.24
13
2.54
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
Standard
Single
Dual
+V Input
+V Input
N.C.
-V Output
N.C.
Common
Omitted
Omitted
-V Output
Common
+V Output
+V Output
-V Input
-V Input
-V Input
-V Input
+V Output
+V Output
-V Output
Common
Omitted
Omitted
N.C.
Common
N.C.
-V Output
+V Input
+V Input
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize
the use of any of its products for use in life support
devices or systems without the express written
approval of an officer of the Company. Life support
systems are devices which support or sustain life,
and whose failure to perform, when properly used
in accordance with instructions for use provided in
the labeling, can be reasonably expected to result
in significant injury to the user. Rev: 5.05 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages