Download

3W DC-DC Converter P3V-Series
●
●
●
●
●
●
Wide 4:1 input range
-40...+85°C operation temperature range
Isolation up to 3500 VDC
MTBF > 1.12 MHours
Continuous short circuit protection
Efficiency up to 80%
Model selection guide
Typ
Single output
P3V243R3S
P3V2405S
P3V247R2S
P3V2409S
P3V2412S
P3V2415S
P3V2418S
P3V2424S
P3V483R3S
P3V4805S
P3V487R2S
P3V4809S
P3V4812S
P3V4815S
P3V4818S
P3V4824S
Dual output
P3V243R3D
P3V2405D
P3V247R2D
P3V2409D
P3V2412D
P3V2415D
P3V2418D
P3V2424D
P3V483R3D
P3V4805D
P3V487R2D
P3V4809D
P3V4812D
P3V4815D
P3V4818D
P3V4824D
Input voltage
range
[VDC]
Input current
No-load
Full-load
[mA]
[mA]
Output
voltage
[VDC]
Output current
min. / max.
[mA]
Efficiency typ.
[%]
Capacitive
load (*1)
[µF]
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
165
160
160
160
155
155
155
155
83
80
80
78
78
78
78
78
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
0...900
0...600
0...416
0...333
0...250
0...200
0...166
0...125
0...900
0...600
0...416
0...333
0...250
0...200
0...166
0...125
75
78
80
80
80
80
80
80
75
78
78
80
80
80
80
80
680
470
100
100
68
47
47
22
680
470
100
100
68
47
47
22
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
165
160
160
160
155
155
155
155
83
80
80
78
78
78
78
78
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
0...±454
0...±300
0...±208
0...±166
0...±125
0...±100
0...±83
0...±63
0...±454
0...±300
0...±208
0...±166
0...±125
0...±100
0...±83
0...±63
75
78
78
80
80
80
80
80
75
78
78
80
80
80
80
80
2 x 330
2 x 220
2 x 47
2 x 47
2 x 33
2 x 22
2 x 22
2 x 10
2 x 330
2 x 220
2 x 47
2 x 47
2 x 33
2 x 22
2 x 22
2 x 10
Add suffix “H” for 3.5kV isolation voltage
Note:
*1 Test by nominal input voltage and constant resistor load
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3V-Series
Specifications
Input :
Filter
Input reflected ripple current
Absolute max. input voltage
24V types
48V types
Isolation:
Rated voltage
input/output 3 sec.
Resistance
Capacitance
Output:
Voltage accuracy
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
General:
Switching frequency
Safety in accordance with
Pi Network
35mAp-p (*2)
-0.7...+40Vp for 100ms max.
-0.7...+80Vp for 100ms max.
1500 VDC, Standard
3500 VDC, Suffix “H”
9
10 Ω
500 pF, typ.
± 1%
± 0.5%, max.
± 0.5%, max.
± 1.5%, max. @ 3.3V output
± 0.02% / °C
60 mVp-p, max. (*3)
Continuous
Automatic
270 kHz, typ.
IEC60950-1:2001
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical :
Dimensions
Weight
Case material
Potting material
Pin soldering temperature
EMC in accordance with
Radiated emissions
Conducted emissions
ESD
RS
EFT
CS
PFMF
Absolute maximum ratings
Input voltage < 100ms
24V Input types
48V Input types
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
see diagram
Up to 95%
Free-air convection
31.75 x 20.32 x 10.16 mm
17 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
260°C for 10s
distance 1.5mm from case
EN55022 class A
EN55022 class A (*4)
IEC61000-4-2 perf. criteria B
IEC61000-4-3 perf. criteria A
IEC61000-4-4 perf. criteria B
IEC61000-4-6 perf. criteria A
IEC61000-4-8 perf. criteria A
-0.7…40 VDC
-0.7…80 VDC
Note:
*2 Measured input reflected ripple current with a simulated source inductance of 12µH
*3 Typical value at nominal input voltage and full load
*4 It's recommended to add C: 68µF, C: 33µF and L: 12µH in input and to achieve EN55022 conducted class A
Application circuit
Efficiency vs output current
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
3W DC-DC Converter P3V-Series
Dimensions
Pin connections
Pin
1
2
10
11
12
13
15
23
24
Single
+V Input
+V Input
N.C.
N.C.
-V Output
+ Output
N.C.
-V Input
-V Input
Dual
+V Input
+V Input
Common
Common
N.C.
-V Output
+ Output
-V Input
-V Input
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or sustain
life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be
reasonably expected to result in significant injury to the user. Rev: 8.10 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]