Download

4W DC-DC Converter P4B-Series
●
●
●
●
●
●
Wide 4:1 input range
-40...+85°C operation temperature range
Isolation up to 3500 VDC
MTBF > 1.121 MHours
Continuous short circuit protection
Efficiency up to 84%
Model selection guide
Typ
Single output
P4B243R3S
P4B2405S
P4B247R2S
P4B2409S
P4B2412S
P4B2415S
P4B2418S
P4B2424S
P4B483R3S
P4B4805S
P4B487R2S
P4B4809S
P4B4812S
P4B4815S
P4B4818S
P4B4824S
Dual output
P4B243R3D
P4B2405D
P4B247R2D
P4B2409D
P4B2412D
P4B2415D
P4B2418D
P4B2424D
P4B483R3D
P4B4805D
P4B487R2D
P4B4809D
P4B4812D
P4B4815D
P4B4818D
P4B4824D
Input voltage
range
[VDC]
Input current
No-load
Full-load
[mA]
[mA]
Output
voltage
[VDC]
Output current
Efficiency typ.
[mA]
[%]
Capacitive
load (*1)
[µF]
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
12
15
18
12
15
15
15
18
10
8
10
10
12
10
10
15
220
210
210
200
205
205
205
205
110
105
100
100
105
100
100
100
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
0...1200
0...800
0...555
0...445
0...333
0...267
0...223
0...167
0...1200
0...800
0...555
0...445
0...333
0...267
0...223
0...167
75
79
79
83
82
82
82
82
76
79
82
83
80
84
84
82
1000
680
220
100
100
68
47
22
1000
680
220
100
100
68
47
22
9...36
9...36
9...36
9...36
9...36
9...36
9...36
9...36
18...72
18...72
18...72
18...72
18...72
18...72
18...72
18...72
12
15
18
18
15
20
25
18
10
15
15
15
12
15
15
15
220
210
210
210
205
210
210
210
105
105
105
105
100
105
100
105
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
0...±605
0...±400
0...±275
0...±223
0...±167
0...±134
0...±112
0...±84
0...±605
0...±400
0...±275
0...±223
0...±167
0...±134
0...±112
0...±84
75
79
79
80
82
80
80
80
78
79
79
80
82
80
81
80
2 x 680
2 x 330
2 x 100
2 x 100
2 x 47
2 x 47
2 x 33
2 x 10
2 x 680
2 x 330
2 x 100
2 x 100
2 x 47
2 x 47
2 x 33
2 x 10
Add suffix “H” for 3.5kV isolation voltage
Note:
*1 Test by nominal input voltage and constant resistor load
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
4W DC-DC Converter P4B-Series
Specifications
Input :
Filter
Input reflected ripple current
Absolute max. input voltage
24V types
48V types
Isolation:
Rated voltage
input/output 3 sec.
Resistance
Capacitance
Output:
Voltage accuracy
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
General:
Switching frequency
Safety in accordance with
Pi Network
35mAp-p (*2)
-0.7...+40Vp for 100ms max.
-0.7...+80Vp for 100ms max.
1500 VDC, Standard
3500 VDC, Suffix “H”
9
10 Ω
500 pF, typ.
± 1%
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
60 mVp-p, max. (*3)
Continuous
Automatic
266 kHz, typ.
IEC60950-1:2001
Environmental:
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical :
Dimensions
Weight
Case material
Potting material
Pin soldering temperature
EMC in accordance with
Radiated emissions
Conducted emissions
ESD
RS
EFT
CS
PFMF
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
see diagram
Up to 95%,
Free-air convection
31.75 x 20.32 x 10.16 mm
17 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
260°C for 10s
distance 1.5mm from case
EN55022 class A
EN55022 class A (*4)
IEC61000-4-2 perf. criteria B
IEC61000-4-3 perf. criteria A
IEC61000-4-4 perf. criteria B
IEC61000-4-6 perf. criteria A
IEC61000-4-8 perf. criteria A
Note:
*2 Measured input reflected ripple current with a simulated source inductance of 12µH
*3 Typical value at nominal input voltage and full load
*4 It's recommended to add C: 68µF, C: 33µF and L: 12µH in input and to achieve EN55022 conducted class A
Application circuit
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
4W DC-DC Converter P4B-Series
Dimensions
Pin connections
Pin
2
3
9
11
14
16
22
23
1.5 / 3.5kVDC
Single
Dual
-V Input
-V Input
-V Input
-V Input
Omitted
Common
N.C.
-V Output
+V Output
+V Output
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or sustain
life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be
reasonably expected to result in significant injury to the user. Rev: 2.10 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages